Extraction Apparatus

Compare Tool

Select up to 3 products

HomeAll Products

Extraction Extraction Apparatus

1 - 32 of 75
Sort
View
Show
  • High Performance Cellulose Extraction Thimbles

    GE Healthcare

    Cellulose extraction thimbles produced from high-quality alpha cellulose cotton linter with excellent mechanical strength and retention. Standard single thickness thimbles have a wall thickness of approximately 1-1.5mm. Double thickness thimbles have a wall thickness of approximately 2mm for…

  • Whatman Quartz Fiber Extraction Thimbles

    GE Healthcare

    High-purity Whatman quartz thimbles from GE support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Appropriate for manual sampling in aggressive environments Suitable for both solvent extraction and air sampling applications …

  • Soxhlet Extraction Apparatus

    Wilmad LabGlass

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • Whatman Extraction Thimbles for DIONEX ASE

    GE Healthcare

    Extraction thimbles for DIONEX ASE 200 extraction cell Extraction thimbles for DIONEX ASE 200 extraction cell

  • PYREX® Extractors With Standard Taper Joints

    Corning

    Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

  • SER 148 Series Solvent Extractors

    VELP

    Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique. Beats Ordinary Soxhlet Extractor Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent) Low…

  • Standard Glass Microfiber Extraction Thimbles

    GE Healthcare

    603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

  • Micro Soxhlet Extraction Apparatus

    DWK Life Sciences (Wheaton)

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • PYREX Soxhlet Extractors

    Corning

    Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • Whatman Glass Soxhlet Extraction Thimbles

    GE Healthcare

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    GE Healthcare

    GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C Binder-free, no chemical additives Designed…

  • Thomas Cellulose Extraction Thimbles

    Thomas®

    Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products,…

  • QM-A Quartz Fiber Filters and Thimbles

    GE Healthcare

    Grade QM-A circles High-purity quartz (SiO2) microfiber filters are used for air sampling in acidic gases, stacks, flues and aerosols, particularly at high temperatures up to 500° C and in PM-10 testing. Because of the low level of alkaline earth metals, "artifact"…

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    This apparatus combines two analytical techniques, Soxhlet extraction and Dean-Stark azeotropic distillation, into a single process for the removal of water, chlorinated dibenzo-p-dioxins (CCDs) and chlorinated dibenzofurans (CDFs) from wet particulate samples. Determination of water and…

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • Cellulose Extraction Thimbles

    Ahlstrom

    Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or…

  • Whatman High Performance Cellulose Extraction Thimbles

    GE Healthcare

    GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction studies, including lipid and pesticide analyses…

  • Extractor, Soxhlet

    Ace Glass

    Soxhlet extactor body with standard taper outer joint at top and 24/40 standard taper inner joint at bottom.

  • Whatman Standard Cellulose Extraction Thimbles

    GE Healthcare

    603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. Thimbles are available in a range of sizes suitable for use in thimble holders and…

  • Photo-Oxidation Apparatus, Ultra-Violet, Flow-Thru

    Ace Glass

    Modified version of 7900 Apparatus. Sample tubes have been replaced with a flow-thru quartz or borosilicate coil for continuous radiation of small or large samples. Consists of a cylindrical lamp housing, medium pressure photochem lamp, quartz or borosilicate coil (with or without jacket), and…

  • Gregar Extractor

    Chemglass

    The Gregar Extractor† is the first major advance in laboratory extractor design in over 100 years. Developed by Joseph Gregar and Ken Anderson of Argonne National Laboratories, this extractor is the only unit on the market that can perform all three common types of extraction. During solid…

  • SYNTHWARE Glass Extraction Thimbles

    Kemtech America

    Extraction Thimble, All Glass Available in multiple sizes (small, medium, large) Porosity: Available in Extra Course and Course All glass extraction thimble permits viewing extraction process and subsequent weighing.

  • Sediment Extraction Apparatus

    Koehler

    Test Method Determines sediment content of crude oil and fuel oils by extraction with toluene. A test portion of the sample is placed in a refractory thimble. Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel. The toluene washes out all of the…

  • Extraction Apparatus, Soxhlet, Micro

    Chemglass

    Micro size Soxhlet extractor for use with 10 x 50mm paper or glass thimbles. Extractor body has a 19/22 top inner joint and a 14/20 lower inner joint. Complete apparatus consists of the extractor body, condenser, and 25mL round bottom flask. Glass thimbles must be ordered separately.

  • Passive Closed Loop Extractors

    Best Value Vacs

    304 Stainless Steel Heavy Duty Miniature Ball Valves System Rated to 100PSI Multiple port connections for _" 316 Stainless SAE 37 Degree Tri-Clamps at all interfaces make for a high pressure, easy clean unit Viton Gaskets are designed for Oil Processing Temp range -40-200F …

  • Xenosep® SPE Starter Kit

    Hach

    At last, an easy, EPA-approved method for oil and grease! Xenosep Solid-Phase Extraction (SPE) Systems offer the easiest and most cost effective way to test for Oil and Grease using EPA Method 1664A. Fast, in-house results enable you to maintain control over your plant discharges in real time…

  • Micro-Quartz Fiber Thimbles, ET/MK360

    Ahlstrom

    Quartz thimbles are used for emission testing in high temperature environments. They can also be used for testing acidic gases which are not compatible with micro-glass fiber thimbles. Quartz meets the highest purity requirements due to the lowest possible heavy metal content.

  • PYREX® 45mm Diameter Coarse Porosity Fritted Thimble, 130mm Long

    Corning

    These 45mm diameter PYREX® coarse porosity (40 to 60µm) fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. These medium length thimbles are 130mm long. For PYREX®…

  • Extraction Thimbles, Glass

    Ace Glass

    With an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…

  • Norton Alundum Extraction Thimbles

    Saint Gobain

    For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • Liquid-Liquid Extractor

    Ace Glass

    For extraction with liquids of lighter density than liquid extracted such as water with ether; 9422 and 9414 are used with extraction flask 9451.

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.