  • Whatman High Performance Cellulose Extraction Thimbles

    Cytiva (formerly GE Healthcare Life Sciences)

    Cytiva (formerly GE Healthcare Life Sciences) Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction…

  • For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • KIMAX SOXHLET TYPE EXTRACTORS

    DWK Life Sciences (Kimble)

    With Standard Taper Joints Complete with Allihn condenser with joint at bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for…

  • Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

  • Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products,…

  • Optimum solution for the acid/basic hydrolysis of food and feed samples prior to solvent extraction for total fat analysis. Improves Analysis Hydrolysis / digestion by acid or base Ensures conformity with AOAC standard No sample transfer – no sample loss Crucibles go…

  • Ideal for laboratory-scale refluxing, botanical extraction, and cannabis extraction applications, Borosil® Soxhlet Extractors are constructed from stress-free, 3.3 Low-Expansion Borosilicate that is mechanically strong and incredibly resistant to thermal shock. Borosil® Soxhlet…

  • High-Purity Glass Extraction Thimbles

    Cytiva (formerly GE Healthcare Life Sciences)

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can…

  • Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique. Beats Ordinary Soxhlet Extractor Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent) Low…

  • Soxhlet type extraction apparatus used for continuous extraction of solids with a suitable solvent. Extractor uses paper or CG-1372 glass thimbles. Condenser has an enlarged uptake tube to improve condensing capacity. Complete apparatus consists of an Allihn condenser, extractor and flat bottom flask.

  • This 47 mm fritted glass support base is designed for assembly with either the 300 mL graduated glass funnel, Cat. No. 33971-300 or 1000 mL graduated glass funnel, Cat. No. 33971-1L.

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • Modular PYREX Accelerated One-Step extractor-concentrator performs extraction, concentration, and drying with the same apparatus and is designed for use with solvents of heavier specific gravity than sample being extracted.  Extraction and concentration can be done in 1/3 of the time.…

  • Test Method Determines sediment content of crude oil and fuel oils by extraction with toluene. A test portion of the sample is placed in a refractory thimble. Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel. The toluene washes out all of the…

  • Improved design of ACE extractor with Friedrichs Condenser in place of Allihn Condenser. Complete consists of flask cap, condenser, extractor, and flask.

  • Whatman Glass Soxhlet Extraction Thimbles

    Cytiva (formerly GE Healthcare Life Sciences)

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…

  • Complete with bulb type condenser and one flask. Cycling rates may be doubled over conventional style extractors. All joints are interchangeable. The 82" size is supplied with adapter for connecting the extractor and condenser. This is necessary because of the extremely large top joint on the extractor.

  • Modified Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    These large capacity Soxhlet extraction apparatus with modified design feature a wide mouth opening that provides easier charging and sample removal and a large area at the filter plate for rapid drainage of the solvent. Bulky solids may be placed directly on a fiberglass mat (not supplied) and…

  • A liquid-liquid extractor for use with lighter or heavier-than-water extracting solvents. Overflow and boil-up tube uses Ace-Thred Connections, thus allowing easy removal for cleaning to reduce cross contamination among samples. Complete consists of:Extractor Body, (approx.1.3L capacity),…

  • These PYREX® coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880.

  • Modified version of 7900 Apparatus. Sample tubes have been replaced with a flow-thru quartz or borosilicate coil for continuous radiation of small or large samples. Consists of a cylindrical lamp housing, medium pressure photochem lamp, quartz or borosilicate coil (with or without jacket), and…

  • Standard Cellulose Extraction Thimbles

    Cytiva (formerly GE Healthcare Life Sciences)

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • All glass extraction thimble permits viewing during extraction process and subsequent weighing. Sizes correspond to CG-1368 or CG-1369 extractor. Available in coarse or extra coarse porosity.

  • Tri-Clamp Ball Valves

    Best Value Vacs

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    Cytiva (formerly GE Healthcare Life Sciences)

    Cytiva (formerly GE Healthcare Life Sciences) Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C …

  • Micro Soxhlet Extraction Apparatus

    DWK Life Sciences (Wheaton)

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • Extra Large Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    This borosilicate glass X-Large Soxhlet extraction apparatus is used for the continuous extraction of solids with a suitable solvent. Complete units are supplied with a round bottom boiling flask (LG-7220-184 or LG-7220-188), a Soxhlet extraction tube (70mm or 100mm approx. I.D.) and an Allihn…

  • With an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…