Soxhlet Extraction Thimbles
-
… Common Glass Microfiber Thimble material applications include gravimetric methods for hot environments, gravimetric methods for acidic gasses, and extraction methods common to biochemical analysis. Common Thimble applications include soxhlet extraction, air and waste gas analysis,…
-
…pesticide residues in food products, extraction of plasticizers from PVC, extraction of dioxins, solid particle such as dust collection in air flows, and evaluation of liquid content in concrete slurry. Common Thimble applications include soxhlet extraction, air and waste gas analysis, collection…
-
Cellulose Extraction Thimbles
Ahlstrom-Munksjo…solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or other noxious solvents. Ahlstrom extraction thimbles are recommended for the estimation of fats in food, analysis of lacquer and binder in paints, vitamin A and carotene extractions, and extraction…
-
Soxhlet Extraction Apparatus
SP Wilmad-LabGlass…Extractor has a Standard Taper outer joint at the top for connection to the condenser and a Standard Taper inner joint at the bottom for connection to the flat bottom boiling flask. Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).
-
Extraction Apparatus, Soxhlet
ChemglassSoxhlet type extraction apparatus used for continuous extraction of solids with a suitable solvent. Extractor uses paper or CG-1372 glass thimbles. Condenser has an enlarged uptake tube to improve condensing capacity. Complete apparatus consists of an Allihn condenser, extractor and flat bottom…
-
Extra Large Soxhlet Extraction Apparatus
SP Wilmad-LabGlass…the siphon tube. The extractor has a standard taper outer joint at the top for connection to the condenser and a standard taper inner joint at the bottom for connection to the flask. *Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).
-
PTFE Extraction Thimble Filters
Advantec MFSHigh purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…
-
Glass Extraction Thimble Filters
Advantec MFS…Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can withstand temperatures up to 500°C making them ideal for high temperature extractions, dust monitoring, or smoke stack gas sampling. They are acid resistant(except hydrofluoric). Thimbles have been…
-
Quartz Extraction Thimble Filters
Advantec MFSHigh purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…
-
Cellulose Extraction Thimble Filters
Advantec MFS…seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for Soxlet extractions…
-
These PYREX® coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880.
-
KIMAX SOXHLET TYPE EXTRACTORS
DWK Life Sciences (Kimble)…bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95 mm (uses 25 mm thimble) Condenser joint Standard Taper 34/45; extraction…
-
Extraction Thimbles, Glass
Ace GlassWith an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…
-
These PYREX® extra coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880. .
-
Extraction Apparatus, Soxhlet, Micro
ChemglassMicro size Soxhlet extractor for use with 10 x 50mm paper or glass thimbles. Extractor body has a 19/22 top inner joint and a 14/20 lower inner joint. Complete apparatus consists of the extractor body, condenser, and 25mL round bottom flask. Glass thimbles must be ordered separately.
-
Soxhlet/Dean Stark Extraction Apparatus
DWK Life Sciences (Kimble)…the need for desiccation prior to Soxhlet extraction Loss of analytes and sample contamination are avoided Uses a 586500-0233 fritted glass extraction thimble, not supplied PTFE stopcock plug is 821001-0002 Manufactured from 33 expansion, low extractable borosilicate glass conforming to…
-
Micro-Glass Fiber Thimbles, ET/MG160
Ahlstrom-MunksjoGlass thimbles are used to sample dust particles and aerosols from gaseous streams in the analytical registration of environmental pollution and for Soxhlet extractions requiring solvents too aggressive for the cellulose thimbles.
-
…(40 to 60µm) fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. These medium length thimbles are 130mm long. For PYREX® extractors and extraction apparatus, see Nos.…
-
Micro Soxhlet, Improved Design
Ace Glass…chemical applications. Improved design permits greater condensing capacity. Condenser approximately 139mm jacket length. Joint between condenser and extractor is 24/25. Flask joint is 14/20. Designed to accommodate paper thimble, size 10 x 50 mm. Flask is 30mL capacity. Hose connections are size B.
-
…for extracting soluble components of impurities from solids by a continuous process of soaking the solid with a solvent and then siphoning residues away. Most of the component parts of the various extractor units have Standard Taper joints for quick, secure connections. Extraction thimbles, paper…
-
Gregar Extractor
Chemglass…eliminates packing and/or channeling of solid samples normally associated with common soxhlet extractors. Complete extractor is supplied with extractor body, cold finger condenser, extra coarse extraction thimble, and solvent guide. The CG-1506-17, 24/40 250mL round bottom flask and auxiliary…