Extraction

Compare Tool

Select up to 3 products

HomeAll Products

Extraction

1 - 32 of 87
Sort
View
Show
  • Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • Base assembly, for 96-well plate manifold

    Agilent Technologies

    The base accomodates lids that hold either a user-defined selection of flexible cartridges, or fixed format 96-well plates with each well loaded with the same sorbent.

  • Norton Alundum Extraction Thimbles

    Saint Gobain

    For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • Standard Glass Microfiber Extraction Thimbles

    GE Healthcare

    603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

  • Micro Soxhlet Extraction Apparatus

    DWK Life Sciences (Wheaton)

    Used for continuous extraction of analytes from a solid into an organic solvent WHEATON Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the…

  • Whatman High Performance Cellulose Extraction Thimbles

    GE Healthcare

    GE’s Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction studies, including lipid and…

  • Extraction Apparatus, Soxhlet, with Friedrichs Condenser

    Ace Glass

    Improved design of ACE extractor with Friedrichs Condenser in place of Allihn Condenser. Complete consists of flask cap, condenser, extractor, and flask.

  • High-Purity Glass Extraction Thimbles

    GE Healthcare

    High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles.…

  • SYNTHWARE Glass Extraction Thimbles

    Kemtech America

    Extraction Thimble, All Glass Available in multiple sizes (small, medium, large) Porosity: Available in Extra Course and Course All glass extraction thimble permits viewing extraction process and subsequent weighing.

  • PYREX® Graduated Funnel, 47 mm, for Assembly with Fritted Glass Support Base

    Corning

    These graduated funnels,are designed for assembly with the fritted glass support base. Cat. No. 33972-B.

  • Vaccuum Manifolds And Accessories

    Agilent Technologies

    Agilent manifolds and accessories complement the quality of AccuBOND II sorbents. Flexible configurations and availability as complete assemblies or individual components mean that the user has the necessary capability at any stage from method development to high throughput operation. Vacuum…

  • Goldfisch Fat Extractor Accessories & Replacement Parts

    Labconco

    Goldfisch Fat Extractor Accessories and Replacement Parts include glassware, gaskets and other components.

  • Micro-Glass Fiber Thimbles, ET/MG160

    Ahlstrom

    Glass thimbles are used to sample dust particles and aerosols from gaseous streams in the analytical registration of environmental pollution and for Soxhlet extractions requiring solvents too aggressive for the cellulose thimbles.

  • Whatman High-Purity Glass Soxhlet Extraction Thimbles

    GE Healthcare

    GE’s Whatman 100% borosilicate glass microfiber (HP-GF) thimbles are designed to fit most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Resistant to temperatures up to 500°C Binder-free, no chemical additives Designed…

  • Soxhlet Extraction Apparatus Flasks

    DWK Life Sciences (Wheaton)

    Flat-bottom flask for Soxhlet Extraction Apparatus 1/Case

  • PYREX® 1L Extractor Body for the Modular Continuous Heavier than Water Liquid…

    Corning

    This 1L PYREX® extractor body has a 45/50 Standard Taper outer top joint, a middle 35/25 Spherical Joint ball joint and a bottom 18/9 Spherical Joint socket joint. It is a component of the modular Continuous Heavier than Water Liquid/Liquid Extractor (Nos. 3922-M and 3924-M) and…

  • Glass Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can…

  • Quartz Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…

  • Cellulose Extraction Thimbles

    Ahlstrom

    Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or…

  • Giant Extraction Apparatus, Soxhlet

    Ace Glass

    Complete with bulb type condenser and one flask. Cycling rates may be doubled over conventional style extractors. All joints are interchangeable. The 82" size is supplied with adapter for connecting the extractor and condenser. This is necessary because of the extremely large top joint on the extractor.

  • Extractor, Soxhlet

    Ace Glass

    Soxhlet extactor body with standard taper outer joint at top and 24/40 standard taper inner joint at bottom.

  • Disposable Liners for Visiprep DL Manifolds

    MilliporeSigma

    Material: PTFE Packaging: Pack of 100

  • QM-A Quartz Fiber Filters and Thimbles

    GE Healthcare

    Grade QM-A circles High-purity quartz (SiO2) microfiber filters are used for air sampling in acidic gases, stacks, flues and aerosols, particularly at high temperatures up to 500° C and in PM-10 testing. Because of the low level of alkaline earth metals, "artifact"…

  • Extraction Apparatus, Liquid-Liquid, Heavier- or Lighter-than-Water

    Ace Glass

    A liquid-liquid extractor for use with lighter or heavier-than-water extracting solvents. Overflow and boil-up tube uses Ace-Thred Connections, thus allowing easy removal for cleaning to reduce cross contamination among samples. Complete consists of:Extractor Body, (approx.1.3L capacity),…

  • Glass Extraction Thimbles

    Chemglass

    All glass extraction thimble permits viewing during extraction process and subsequent weighing. Sizes correspond to CG-1368 or CG-1369 extractor. Available in coarse or extra coarse porosity.

  • PTFE Extraction Thimble Filters

    Advantec MFS

    High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • Whatman Quartz Fiber Extraction Thimbles

    GE Healthcare

    High-purity Whatman quartz thimbles from GE support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Appropriate for manual sampling in aggressive environments Suitable for both solvent extraction and air sampling applications …

  • Whatman Glass Soxhlet Extraction Thimbles

    GE Healthcare

    603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Modified Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    These large capacity Soxhlet extraction apparatus with modified design feature a wide mouth opening that provides easier charging and sample removal and a large area at the filter plate for rapid drainage of the solvent. Bulky solids may be placed directly on a fiberglass mat (not supplied) and…

  • CHROMABOND® vacuum manifold

    MACHEREY-NAGEL

    For simultaneous preparation of up to 12, 16 or 24 samples

  • Standard Cellulose Extraction Thimbles

    GE Healthcare

    Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • Photo-Oxidation Apparatus, Ultra-Violet, Flow-Thru

    Ace Glass

    Modified version of 7900 Apparatus. Sample tubes have been replaced with a flow-thru quartz or borosilicate coil for continuous radiation of small or large samples. Consists of a cylindrical lamp housing, medium pressure photochem lamp, quartz or borosilicate coil (with or without jacket), and…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.