Extraction

Compare Tool

Select up to 3 products

HomeAll Products

Extraction

1 - 32 of 90
Sort
View
Show
  • Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products,…

  • Filtration Vacuum Pump Kit

    GSC International, Inc.

    This Filtration Kit allows rapid separation of mixtures via vacuum filtration. The stopper is cut to hold a Buchner funnel. The hand-operated vacuum pump simplifies vacuum filtration, eliminating the need for a water source or vacuum aspirator. It is more economical than an electric vacuum pump.…

  • Cytiva Whatman cellulose thimbles are manufactured from high-quality alpha cellulose cotton linter for high-performance use in automated Soxhlet extractor systems. Used in air and waste gas analysis. Used in a wide variety of solid-liquid extraction studies, including lipid and pesticide…

  • Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique. Beats Ordinary Soxhlet Extractor Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent) Low…

  • Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

  • Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    Used for the continuous extraction of solids with a suitable solvent. Units are supplied complete with flat bottom boiling flask, Soxhlet extractor and Allihn condenser. The extractor capacity shown is the solvent volume held in the extractor to the top of the siphon tube. The siphon tube is…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Cellulose Fiber is made from alpha cotton cellulose. These thimbles are binder-free and suitable for…

  • The base accomodates lids that hold either a user-defined selection of flexible cartridges, or fixed format 96-well plates with each well loaded with the same sorbent.

  • 603G borosilicate glass fiber thimble with inorganic binder Resistant to temperatures up to 500°C (932°F) Manufactured with walls as thin as 1–1.5 mm Resistant to temperatures up to 500°C (932°F)Manufactured with walls as thin as 1–1.5 mm603G borosilicate glass fiber thimble with inorganic…

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    This apparatus combines two analytical techniques, Soxhlet extraction and Dean-Stark azeotropic distillation, into a single process for the removal of water, chlorinated dibenzo-p-dioxins (CCDs) and chlorinated dibenzofurans (CDFs) from wet particulate samples. Determination of water and…

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Advantec offers thimble filters in pure PTFE Fiber and PTFE/Silica Fiber. PTFE is inherently hydrophobic…

  • Tapered branch accepts 40/35 female joint Broad base for extra stability Ideal for EPA Method 1664 oil and grease analysis Lightweight and durable PVC material makes this extraction manifold a great alternative to stainless steel. Polyvinylchloride(PVC) is resistant to acids. The…

  • Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

  • These PYREX® coarse porosity fritted thimbles are designed for use in PYREX® Soxhlet extractors when it is desirable to weigh the material extracted or where paper thimbles may be attacked by the chemicals used. For PYREX® extractors and extraction apparatus, see Nos. 3740 through 3880.

  • Test Method Determines sediment content of crude oil and fuel oils by extraction with toluene. A test portion of the sample is placed in a refractory thimble. Toluene is gently boiled and its vapors condensed and allowed to drip into the sample funnel. The toluene washes out all of the…

  • This 47 mm fritted glass support base is designed for assembly with either the 300 mL graduated glass funnel, Cat. No. 33971-300 or 1000 mL graduated glass funnel, Cat. No. 33971-1L.

  • KIMAX SOXHLET TYPE EXTRACTORS

    DWK Life Sciences (Kimble)

    With Standard Taper Joints Complete with Allihn condenser with joint at bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95…

  • Gregar Extractor

    Chemglass

    The Gregar Extractor† is the first major advance in laboratory extractor design in over 100 years. Developed by Joseph Gregar and Ken Anderson of Argonne National Laboratories, this extractor is the only unit on the market that can perform all three common types of extraction. During solid…

  • With an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…

  • For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

  • Ideal for laboratory-scale refluxing, botanical extraction, and cannabis extraction applications, Borosil® Soxhlet Extractors are constructed from stress-free, 3.3 Low-Expansion Borosilicate that is mechanically strong and incredibly resistant to thermal shock. Borosil® Soxhlet…

  • 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. 603 Standard Cellulose Extraction Thimbles made from high-quality cellulose available in a range of sizes. Thimbles are available in a range of sizes suitable for use in thimble holders and…

  • At last, an easy, EPA-approved method for oil and grease! Xenosep Solid-Phase Extraction (SPE) Systems offer the easiest and most cost effective way to test for Oil and Grease using EPA Method 1664A. Fast, in-house results enable you to maintain control over your plant discharges in real time…

  • Extractor body only, with stopcock for withdrawing samples from extraction chamber. Can be used interchangeably with the standard Soxhlet extraction apparatus.

  • High purity, seamless thimble filters offered in 5 materials. Applications include analysis of fats, oils, grease, pesticides, pollutants, organics and addititives in plastics and rubbers. Silica Fiber (Quartz) thimbles are made of pure quartz microfibers and are binder-free. Ideal for air…

  • Extraction System

    Avantor - J.T.Baker®

    The BAKER SPE-12G is compatible with a large variety of glassware, including standard test tubes, volumetric flasks and autosampler vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted…

  • Soxhlet Extraction Apparatus Flasks

    DWK Life Sciences (Wheaton)

    Flat-bottom flask for Soxhlet Extraction Apparatus 1/Case

  • 125 ml App, Soxhlet Extraction, Gnd

    DWK Life Sciences (Wheaton)

    Use this apparatus for continuous extraction of analytes from a solid into an organic solvent. As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the water-cooled condenser, and liquate. When the liquid level in the extractor reaches the top of the bent…

  • Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic or…

  • Extractor, Soxhlet

    Ace Glass

    Soxhlet extactor body with standard taper outer joint at top and 24/40 standard taper inner joint at bottom.

  • 603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.