PerkinElmer Gas Chromatography Columns
-
Temperature range: -20 to 320 degrees celsius. Similar to USP G43 phase.
-
Temperature range -60oC to 200 oC
-
Elite 1301 capillary column 30m x 0.25mm, 1.00µm
PerkinElmerTemperature range -20°C to 260/280°C Equivalent to USP G43 phase
-
Elite-1 capillary column, 15m x 0.32mm, 3.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
The Elite-Betacydex Columns for chiral separations that are 30 m long and have an inner diameter of 0.25 mm.
-
-
Elite-WAX capillary column 30m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Elite-WAX capillary column 30m x 0.53mm, 1.00µm
PerkinElmerTemperature range 20oC to 240/250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
Temperature range -60°C to 320/340°C.
-
Elite-1 capillary column, 40m x 0.18mm, 0.40µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-Siltek Guard, 5m x 0.32mm
PerkinElmerElite-Siltek Guard Columns lengthen the life of the capillary columns.
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 30m, Inner Diameter: 0.32mm, Film Thickness: 0.50m, Temperature Limits:30 to 340/360C
-
Our new line of Velocity fused silica columns yield exceptional performance for general Gas Chromatography (GC) applications without the cost associated with gas chromatography and mass spectrum analysis. PerkinElmer Velocity columns are excellent for standard daily test applications. They combine…
-
Elite-200 capillary column 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 290/310°C.
-
Temperature range -60°C to 300/315°C.
-
Elite-5ht capillary column 15m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
Equivalent to USP G27 and G36 phases Temperature range -60°C to 330/350°C
-
Equivalent to USP G27 and G36 phases Temperature range -60°C to 330/350°C
-
-
Elite-5 capillary column, 60m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C
-
Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAMEs,…
-
-
-
Elite 1301 capillary column 30m x 0.53mm, 1.00µm
PerkinElmerTemperature range -20 o C to 280 o C. Equivalent to USP G43 phase.
-
Elite-5 capillary column, 30m x 0.53mm, 1.50µm
PerkinElmerEquivalent to USP G27 and G36 phases Temperature range -60°C to 350°C.
-
Elite-WAX capillary column 30m x 0.53mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
Elite-WAX capillary column 60m x 0.32mm, 0.50µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
-
Elite-1MS capillary column, 30m x 0.32mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C