  • The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…

  • Part of the Cyclonic/Concentric Kit 8x00 which includes: 1 Slot Quartz Torch, 2.0 mm i.d. Alumina Injector, Glass Cyclonic Spray Chamber, Meinhard ® Type K1 Nebulizer, Quartz Torch Copper Ignitor Tape – Qty. 50 pcs.

  • The MEINHARD concentric glass nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control.

  • The Slurry Nebulizer excels at the analysis of slurries. One common slurry application is the analysis of used engine oils for wear metals. Any sample which consists of small particulates in a liquid matrix is a slurry and is suited to this nebulizer. Samples that contain high dissolved solids are…

  • The Tip Kit includes a clear sapphire sample tip and a red ruby argon tip. The tips are constructed of PEEK with the gem inserts noted for maximum corrosion resistance.

  • The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are…

  • MicroFlow nebulizers are resistant to clogging, reliably self-aspirated or pumped to produce a fine aerosol for high transport efficiency and high sensitivity. The PFA-ST3 Nebulizer is designated for superior clog resistance and higher sensitivity compared to the standard PFA nebulizer. • All PFA…

  • The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.

  • O-Ring E6000 Sampler

    PerkinElmer

    We offer replacement Sampler Cone O-Rings for the ELAN 6000 inductively coupled plasma mass spectrometry (ICP-MS) model.

  • One of the Viton torch ball joint o-rings is included in the Quartz Torch O-Ring Kit (N0770437).

  • The Scott spray chamber is made from corrosion-resistant material, which is inert to most mineral acids including hydrofluoric acid, aqua regia and all organic solvents normally used in ICP analyses. The Scott-type design minimizes pulsations from the peristaltic pump. The Type II, two-piece design…

  • Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • The MicroMist ™ micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.6 mL/min are fitted with a UniFit connector with 1.3 mm O.D. x 0.50 mm I.D. x 700 mm long sample tubing (N0777513). MicroMists with sample uptakes 0.05…

  • This product is a PFA MicroFlow Nebulizer with Integrated Autosampler Probe and carbon fiber support. It self-aspirates at low-flow rates with any autosampler and provides the same benefits of the PFA MicroFlow nebulizer. The integrated sampling probe is constructed by encapsulating a rigid support…

  • The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant…

  • Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • Replacement tubing for internal standard kit.

  • DuraMist Nebulizer 1.0 mL/Min

  • PFA-200 MicroFlow nebulizer with integrated capillary. Self-aspirating 200 µL/min PFA nebulizer for high-purity and semiconductor applications.

  • Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…

  • This kit includes: Fixed 2.5 mm Injector Quartz Torch (Green Mark) qty.2 (N8152473) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber with Matrix Gas Port qty.1 (N8152389) Threaded Spray Chamber Drain Line qty. 2 (N8152456) Nickel Skimmer Cone qty.2 (W1026356) …

  • Used to align the torch in the load coil.

  • The spray chamber's gas ports designed to be used with any addition gas. The spray chamber provides low blanks.

  • .043ODx.018 ID polyethylene tubing 100ft for Mira Mist Nebulizer

  • Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.

  • This nebulizer adapter plug 16/6 is used with standard glass cyclonic spray chambers (N0776052) in Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.

  • Concentric Plus Nebulizers provide low dead volume and high sensitivity with excellent detection limits and washout. Each Plus nebulizer includes the FitKit+ gas and sample quick connect fittings. The connections are made with highpurity PFA, minimizing the chance of contamination during backflow…

  • The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.

  • Four Male Peripump Union barb fittings are included in the NexION 2000 ICP-MS Base Configuration's Consumable Kit (N8150054), Core Configuration's Consumable Kit (N8150055), Productivity Configuration's Consumable Kit (N8150056), and Semi Configuration's Consumable Kit (N8150057).

  • This Kit includes: Viton ® O-Ring 20.29 mm I.D. (09210598) O-Ring 29.74 mm I.D. (09902131) O-Ring 36.09 mm I.D. (09921058) O-Ring 26.57 mm I.D. (09921062) Round Window 31.75 mm Diameter (09992731) Tube Assembly - Century B Radial View (09992731)

  • Precision-designed and manufactured, large-orifice sampler and skimmer cones provide superior long-term stability and resist clogging, allowing analysis under both high and low sample-uptake conditions. Nickel is a very rugged, long-lasting material for the majority of sample types, while platinum…

  • This baffled cyclonic spray chamber, made of borosilicate glass, is an integral part of the sample introduction system responsible for filtering the sample mist to permit appropriate droplet size distribution to reach the plasma. The spray chamber features a sand-blasted neck with EZ seal fitting…