Samplers

Compare Tool

Select up to 3 products

1 - 32 of 583
Sort
View
Show
  • 88-Position Polypropylene Tray for PerkinElmer AS-800 Graphite Furnace Autosampler, 80 sample locations for 2mL, 2.5mL or 3.5mL sample cups, 8 positions for 7mL reagent containers.

  • 5 position extra standards rack for 50 mL and 250 mL bottles. Fits over SC-DX rinse station.

  • TFM Pressure Seal for High Pressure 100 mL (100 Bar) Digestion Vessels for Titan MPS 16 Position Microwave Sample Preparation Systems. Made of TFM Quantity: set of 5

  • 28 mm o.d. polypropylene tube with screw cap, Quantity: 50, Volume: 50 mL. Non-PFA sample vessels manufactured from plastics, such as polypropylene, polyethylene and polystyrene, are a sensible alternative to consider when breakage, surface inertness, and/or disposal costs are a concern.

  • PEEK Sample Loops avoid many of the problems associated with stainless steel sample loops. Metal loops will often absorb sample components resulting in inaccurate quantitative results. In addition, metal loops may be corroded by high-salt buffers and chloride salts. Sample Loops are made from PEEK…

  • The wide-mouth bottle's cap has a 0.32 cm (1/8 in) hole in the center.

  • 4DX-FAS Autosampler Includes: 2 Sample Probes Standards Rack (10 positions) 4 Large Racks (21, 40, 60, 90 positions) 50 mL Standards Vials (pack of 10) 15 mL Sample Vials (pack of 60) Features and Benefits: Small footprint (295mm x 770mm) Dual flowing rinse station, mimics best manual…

  • Black PEEK Threaded Adapter

  • Dual 500 mL polypropylene bottle kit with -28 fittings with 0.5 mm (Orange) internal lines and filtered air inlets. Labeled Carrier/Blank and Working solution.

  • This 40-position autosampler sample rack features square holes, with side length of 20.6 mm, designed for 20 mL vials. Rugged racks are molded of autoclavable polypropylene. Footprint dimensions fit many different auto samplers. Each rack features end plates for labeling as well as numbered and…

  • 30ml Polypropylene, 25mm x 95mm (500 PER KIT)

  • This configuration of the FAST Flame 1 accessory is a combination of 4DX-FAS high-speed autosampler, one precision peristaltic pump and a switching valve. It provides quick sample turnaround with: Fast rinse-out Short signal stabilization times No sample-to-sample memory effect The FAST Flame…

  • 13 position Holder for Sampling screen (MZ305382) for use with on the Direct Sample Analysis (DSA) Ion Source for AxION 2 TOF MS.

  • Vacuum Pump 115V

    PerkinElmer

    The vacuum assisted Digi FILTER assembly provides a quick and easy way to filter samples prior to analysis.

  • SPE Vacuum Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used.   Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump.   Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of…

  • This configuration of the FAST Flame 2 accessory is a combination of the 2DX-FAS high-speed autosampler, two precision peristaltic pumps and a switching valve, providing quick sample turnaround with fast rinse-out, short signal stabilization times and no sample-to-sample memory effect. The FAST…

  • For busy labs, additional acid resistant, polycarbonate Racks are available for all SPB systems. Exclusive RackLock feature locks DigiTUBEs in position within the rack allowing for easy, one-handed closure of screw cap.

  • The PerkinElmer 90 mm Plastic Petri Dishes are suitable for NIRA II 100 mm spinner. Includes pack of 600 transparent polystyrene Petri dishes with lids 90 mm diameter.

  • 8 Position turntable system with High Pressure 100 mL (100 Bar) Digestion Vessels (complete assembly) for Titan MPS™ 8 and 16 Position Microwave Sample Preparation Systems, includes 8 High Pressure 100 mL (100 Bar) Digestion Vessels made of TFM with TFM Sample Vessel Insert Ceramic Pressure…

  • The foam storage rack is used to store up to 12 100 mL DigiTUBEs. Comes in packs of five.

  • This ASX-1400 Autosampler, configured for use with three 80-position CETAC racks, incorporate a simple stirring paddle to homogenize each sample automatically prior to analysis. Variable speed control ensures proper mixing of the samples and more precise results. It includes: Rinse pump:…

  • Consists of pressure seal, Closure cap with DPC, Rupture Disc, TFM Vessel insert, Ceramic pressure jacket and Vessel base.

  • These vials are ideal for applications that require the highest sensitivity. Made of ultra-pure, ultra-chemically resistant material, these vials are an excellent choice for high purity, semiconductor and micro-samples. Benefits: Non-contaminating Graduated Temperature range of -200 °C to 260…

  • PTFE sealing ring for use with 8 and 16 position Gas Containment Manifolds for Titan MPS 8 and 16 Position Microwave Sample Preparation Systems.

  • This kit includes: GemTip Cross-Flow II Nebulizer (N0780546) 1-Slot Quartz Torch (N0790131) 2.0 mm Alumina Injector (N0791183) Ryton Scott Double-Pass Spray Chamber (N0790384)

  • This configuration of the AAPrep2 accessory consists of a 2DX-FAS autosampler and two peristaltic pumps. It provides the ability to: Mechanically pump the sample during injection Optimize nebulizer and flame conditions Eliminate variability due to changes in sample viscosity, dissolved solids…

  • This ASX-1400 Autosampler, configured for use with four 96-position CETAC racks, incorporate a simple stirring paddle to homogenize each sample automatically prior to analysis. Variable speed control ensures proper mixing of the samples and more precise results. It includes: 4 each 96 position…

  • Microtiter plates are ideal for micro volume applications such as storage and sample transfer. 1 Pack (5 each) 48 well, 5 mL microtiter plate, square well, pyramid bottom.

  • PerkinElmer offers SPB Start Up kits containing all consumable items required to operate the system including: RackLockDigiTUBEs and Caps, disposable Watch Glasses, DigiFILTERs, RackLock Racks and Storage Racks. Includes 500Caps, 1,000 Watch Glasses, 2 Racks.

  • The PerkinElmer Sample Tray for PerkinElmer AS-93 plus/S10 Autosampler with 60 locations for 15 mL solution containers.

  • This configuration of the FAST Flame 1 accessory is a combination of 2DX-FAS high-speed autosampler, one precision peristaltic pump and a switching valve. It provides quick sample turnaround with: Fast rinse-out Short signal stabilization times No sample-to-sample memory effect The FAST Flame…

  • QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting AOAC 2007. 01 methodology. Volume: 15 mL Quantity: 50 MgSO41: 1200 mg PSA2: 400 mg PGC3: 400 mg1 MgSO4 removes excess water 2 PSA removes sugars, fatty acids, organic acids, and anthocyanine pigments 3 PGC (carbon) removes…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.