PerkinElmer ICP-MS
-
Torch O-Ring Kit for Optima 8x00
PerkinElmerThis kit includes: O-Ring 29.74 mm I.D., Qty. 1 (09902131) O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 28.17 mm I.D., Qty. 1 (09921061) O-Ring 26.57 mm I.D., Qty. 1 (09921062) Silicone Super-O-Lube, 2 grams (09200078)
-
This one-piece quartz torch, marked blue, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Base Configuration's Sample Introduction Kit (N8150034).
-
The 32 cm PTFE drain line has a 1/4-28 spray chamber fitting. 160 cm of additional 0.8 mm I.D. drain line tubing is included.
-
The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are…
-
The baffled cyclonic spray chamber, made of perfluoroalkoxy alkanes (PFA), is an all-purpose hydrofluoric acid-resistant spray chamber. It features o-ring-free connections to the nebulizer and torch injector, secure, leak-free threaded drain port, internal baffle, and threaded auxiliary port for…
-
This nebulizer self-aspirates at low-flow rates with any autosampler and provides the same benefits of the PFA MicroFlow nebulizer. The integrated sampling probe is constructed by encapsulating a rigid support material between layers of PFA to provide a chemically-resistant probe that is…
-
GemCone High Dissolved Solids Nebulizer
PerkinElmerHigh solids Gem Cones are for samples with high dissolved solids (up to 20%). This cone spray nebulizer allows you to analyze samples with higher solids concentration than is possible with a Cross-Flow nebulizer. Gem Cone nebulizers require an end cap for use with Ryton Scott Spray Chambers. High…
-
This kit includes: Glass Standard Cyclonic Spray Chamber (N0776052) Cyclonic Spray Chamber Mount Kit (N0770131) Cyclonic Spray Chamber Mount Nut (N0776005) Cyclonic Spray Chamber Mount Sleeve (N0776004) Cyclonic Spray Chamber Mount Ring (N0776003) 20 mm M4 Cap Screw (09919167) 6 mm M3 Cap…
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
-
This o-ring-free baffled cyclonic spray chamber, made of borosilicate glass, comes standard with NexION Q, X, and D models. It relies on momentum to ef ciently and quickly remove the larger droplets from the sample mist decreasing any opportunity for occlusion or agglomeration of the smaller…
-
1-Slot Quartz Outer Tube for Optima 8x00 D-Torch
PerkinElmerThe D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
The internal standard mixing tee is perfect for online addition of internal standard or online dilution. Achieves excellent mixing with minimal dead volume.
-
Adjustable Torch Mount Assembly for Avio 200
PerkinElmerThe adjustable torch mount assembly is included in the Adjustable Torch Body Assembly (N0790138). This assembly includes: Torch Mount, Qty 1. (N0791285) Disk Magnet, Qty. 1 (09200515)
-
Laminar flow spray chamber addition gas tee, with F5 fittings and 1/4 PFA gas line fitting, for NexION 300 and 350 ICP-MS series instruments.
-
This module kit includes: Baffled Cyclonic Spray Chamber, Qty. 1 (N0791352) 2 mm Alumina Injector, Qty. 1 (N0791183) 1-Slot Quartz Torch, Qty. 1 (N0790131) MEINHARD Type K Nebulizer, Qty. 1 (N0777707) Nebulizer Connector Assembly, Qty. 1 (N0791018) Injector Adapter Kit, Qty. 1 (N0790141) …
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils. This…
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
0-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
The MicroMist ™ micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.6 mL/min are fitted with a UniFit connector with 1.3 mm O.D. x 0.50 mm I.D. x 700 mm long sample tubing (N0777513). MicroMists with sample uptakes 0.05…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
This kit includes: Demountable Quartz Torch PVDF qty.2 (N8152379) 2.0 mm Demountable Quartz Injector qty.2 (N8152376) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber with Matrix Gas Port qty.1 (N8152389) Threaded Spray Chamber Drain Line qty.2 (N8152456) …
-
PFA-200 Microflow Nebulizer 20 uL/min
PerkinElmerPFA-200 Microflow Nebulizer, 200 µL/min, with integrated autosampler probe [Ultem support] for ESI SC Autosampler. HF Resistant. Capillary length 150cm. Probe length 175 mm.
-
1-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
Adapter Tubing GemTip Nebulizer
PerkinElmerUsed to connect capillary tubing (Product Number: 09908265) to Cross-flow nebulizers, and to larger i.d. peristaltic pump tubing.
-
2 mm gas line with UpChurch fingertight fittings for Mira Mist and Ari Mist nebulizers.
-
Type C0.5 Glass Nebulizer for NexION
PerkinElmerThe MEINHARD® Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and…
-
Ryton Scott Spray Chamber for Avio 200/500
PerkinElmerThe spray chamber is an integral part of the sample introduction system responsible for filtering the sample mist to permit the appropriate droplet size distribution to reach the plasma. It is corrosion resistant and is inert to most mineral acids, including hydrofluoric acid, aqua regia, and all…
-
This one-piece SilQ torch, marked white, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Semiconductor Configuration's Sample Intruduction Kit (N8150037).
-
The baffled cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…
-
Nebulizer liquid fitting with ETFE capillary tubing - 4 length by 0. 020 ID x 0. 062 OD flanged onto female CTFE fitting Includes one male barb CTFE fitting.
-
The 50 mL borosilicate glass cyclonic Tracey spray chamber does not feature an internal baffle and is not hydroflouric acid-resistant. It relies on momentum to efficiently and quickly remove the larger droplets from the sample mist decreasing any opportunity for occlusion or agglomeration of the…