Gas Chromatography Columns

Compare Tool

Select up to 3 products

HomeAll Products

Restek Columns Gas Chromatography Columns

1 - 32 of 140
Sort
View
Show

  • MXT-65TG Columns (Siltek-treated stainless steel)

    Restek

    high-polarity phase; Crossbond diphenyl dimethyl polysiloxane The MXT-65TG phase resolves triglycerides by degree of unsaturation as well as by carbon number. Because of the chemistry required to achieve 370°C thermal stability, an MXT-65TG column should not be used for analyses of…

  • Rxi-1ms Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…

  • Rtx-1701 Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…

  • Rtx-BAC Plus 1 Columns (fused silica)

    Restek

    These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…

  • Hydroguard-Treated MXT Guard/Retention Gap Columns/Transfer Lines (passivated…

    Restek

    Extend analytical column lifetime by preventing degradation from harsh "steam-cleaning" water injections Maximum temperature: 325°C When transfer lines from purge-and-trap systems, air monitoring equipment, or other instruments carry condensed water vapor, deactivated column…

  • Rt-QS-BOND Columns (fused silica PLOT)

    Restek

    porous divinylbenzene homopolymer Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic…

  • MXT-Q-BOND Columns (Siltek-treated stainless steel PLOT)

    Restek

    Advantages of metal MXT PLOT columns include: Can be made in small coil diameters—perfect for tight spaces. Rugged material withstands rough handling and shock. Designed for robust performance in process GCs and field instruments. Available in 3.5"-coil diameter or…

  • Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…

  • Rtx-35 Amine Columns (fused silica)

    Restek

    midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-35 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…

  • Stabilwax Columns (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…

  • Rxi-5Sil MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…

  • Rtx-PCB Columns (fused silica)

    Restek

    proprietary Crossbond phase Unique polymer for PCBs analysis by GC-ECD or GC-MS. Good results for other semivolatiles. Low polarity; inert to active compounds. Stable to 340°C

  • Rtx-Wax Columns (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol Rtx-Wax columns are the most inert and efficient PEG columns currently available. The extended operating temperature range allows analysis of compounds having a wide volatility range and ensures low bleed at temperatures as high as 250°C.…

  • MXT-Biodiesel TG Columns (Siltek-treated stainless steel)

    Restek

    Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430°C for reliable, consistent performance.

  • Rtx-BAC2 Columns (fused silica)

    Restek

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…

  • Rt-S-BOND Columns (fused silica PLOT)

    Restek

    porous divinylbenzene homopolymer Porous polymers are unique, highly retentive stationary phases with a wide application range that are able to elute both polar and nonpolar compounds. They are very hydrophobic, so water has no impact on retention times and even elutes as a good chromatographic…

  • Rxi-XLB Columns (fused silica)

    Restek

    low-polarity proprietary phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • FAMEWAX Columns (USP G16) (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…

  • Rtx-VRX Columns (fused silica)

    Restek

    proprietary Crossbond phase The Rtx-VRX stationary phase and optimized column dimensions provide low bleed, excellent resolution, and fast analysis times for volatile compounds. Application-specific columns for volatile organic pollutants. Excellent for U.S. EPA Method 8021 compounds. …

  • MXT-500 SimDist Column (Siltek-treated stainless steel)

    Restek

    nonpolar phase Manufactured from Siltek treated stainless steel tubing, MXT columns are the most durable high temperature GC columns available. As outlined in ASTM Method D6352, high temperature simulated distillation requires a column that can withstand temperatures to 430°C. MXT-1HT…

  • Molecular Sieve Columns

    Restek

    Molecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek’s R&D chemists have developed a process for preparing molecular sieve packings, which results in excellent batch-to-batch reproducibility. In addition, our molecular sieves are…

  • Rtx-200 Secondary Columns for GCxGC (fused silica)

    Restek

    midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropyl stationary phase…

  • Rtx-502.2 Columns (fused silica)

    Restek

    proprietary Crossbond diphenyl/dimethyl polysiloxane phase An Rtx-502.2 column will enable you to quantify all compounds listed in U.S. EPA methods 502.2 or 524.2, whether you use a mass spectrometer or a PID in tandem with an ELCD. The diphenyl/dimethyl polysiloxane based Rtx-502.2 stationary…

  • Rxi-1301Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Cyano-based 1301 columns are general use GC columns that are well suited for the analysis of solvents across a range of volatilities. The cyano stationary phase provides more retention of polar compounds than a 5-type column; however, cyano-based stationary phases…

  • CarboBlack Packing Materials

    Restek

    CarboBlack B supports up to 10% loading of a nonsilicone liquid phase CarboBlack C supports up to 1% loading of a nonsilicone liquid phase Graphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available,…

  • Rxi-1HT Columns (fused silica)

    Restek

    nonpolar phase; dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Deactivated Fused Silica Tubing (Nonpolar)

    Restek

    Useful as guard columns, transfer lines, or long retention gaps Inertness-tested with the Grob test mix includes test chromatogram. 5-meter banded sections mounted in a Restek cage. Maximum temperature: 325°C Note: 30- and 60-meter lengths are banded in 5-meter sections. …

  • Rxi-XLB Secondary Columns for GCxGC (fused silica)

    Restek

    low polarity proprietary phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Rxi-PAH Columns (fused silica)

    Restek

    midpolarity proprietary phase The Rxi-PAH GC columns were designed by Restek with a higher phenyl-content stationary phase that provides unique selectivity to separate important polycyclic aromatic hydrocarbons (PAH) for food safety that cannot be distinguished by mass spectrometry. Even…

  • CarboBlack Columns

    Restek

    Graphitized carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a nonsilicone liquid phase.…

  • Rt-yDEXsa Columns (fused silica)

    Restek

    2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl gamma cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…

  • Rtx-Biodiesel TG Columns (fused silica)

    Restek

    Linearity for all reference compounds exceeds method requirements. Columns with retention gaps feature Alumaseal connectors to prevent leaks and extend column life. Low column bleed at high temperatures. For glycerin and glycerides analysis, according to ASTM D6584 and EN 14105 methods. …

Compare Tool

Select up to 3 products

Please Log In