  • Rtx-1 Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane General-purpose columns for solvent impurities, PCB congeners (e.g., Aroclor mixes), simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds, essential oils, hydrocarbons, semivolatiles, pesticides, oxygenates. …

  • Rtx-5 (G27) Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane The diphenyl dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. All residual catalysts and low molecular weight fragments are removed from the Rtx-5 polymer,…

  • Rxi-624Sil MS Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of column…

  • Rtx-1301 (G43) Columns (fused silica)

    Restek

    low- to midpolarity phase Many analysts feel the Rtx-1301 column has the best cyanosiloxane bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility,…

  • Rxi Guard/Retention Gap Columns (fused silica)

    Restek

    Extend column lifetime. Excellent inertness—obtain lower detection limits for active compounds. Sharper chromatographic peaks by utilizing retention gap technology. Maximum temperature: 360°C

  • Stabilwax-DA Columns (fused silica)

    Restek

    polar phase; Crossbond acid-deactivated Carbowax polyethylene glycol—for acidic compounds Stabilwax-DA bonded polyethylene glycol has an acidic functionality incorporated into the polymer structure. This permits analysis of acidic compounds without derivatization, significantly reduces…

  • Polar-Deactivated Guard/Retention Gap Columns (fused silica)

    Restek

    polar polyethylene glycol deactivation Tested with a comprehensive test mix to ensure high inertness Polyethylene glycol deactivation layer provides optimum wettability for polar compounds Minimize peak splitting when using polar solvents such as methanol or water Compatible with…

  • Rtx-5MS—Low-Bleed GC-MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners (e.g., Aroclor mixes), essential oils, semivolatiles. Column specifically tested for low-bleed performance. Temperature range:…

  • Rtx-BAC2 Columns (fused silica)

    Restek

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…

  • Stabilwax Columns (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…

  • Porous Polymer Columns

    Restek

    Restek offers a full range of porous polymers, including HayeSep and Porapak polymer packings for analyses of volatile compounds and light solvents.

  • Rxi-5ms Columns (fused silica)

    Restek

    low-polarity phase; Crossbond diphenyl dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this…

  • Rtx-5 Amine Columns (fused silica)

    Restek

    low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane Active basic compounds that otherwise require derivatization, or an alternative analytical technique, can be analyzed on an Rtx-5 Amine column. The tubing surface is chemically altered to reduce tailing of basic compounds,…

  • Rxi-1ms Columns (fused silica)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to outstanding performance, this combination of…

  • Fused Silica Tubing (Undeactivated, Untreated)

    Restek

    Strength-tested Inexpensive Coiled in 7-inch diameters, banded in 5-meter sections, and mounted in a Restek cage

  • Rtx-50 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond phenyl methyl polysiloxane The high thermal stability of Rtx-50 columns makes dual-column analysis possible with common phases such as Rtx-1 or Rtx-5MS. General-purpose columns for pesticides, herbicides, rosin acids, phthalate esters, sterols Equivalent to…

  • Rtx-624 Columns (fused silica)

    Restek

    low- to midpolarity phase The unique polarity of the Rtx-624 column makes it ideal for analyzing volatile organic pollutants. Although the Rtx-502.2 column is recommended in many methods, the Rtx-624 column offers better resolution of early eluting compounds. The Rtx-624 phase produces greater…

  • MXT-1 Columns (Siltek-treated stainless steel)

    Restek

    nonpolar phase; Crossbond dimethyl polysiloxane MXT-1 columns exhibit long lifetime and very low bleed at high operating temperatures. A proprietary synthesis process eliminates residual catalysts that could cause degradation and increase bleed. General-purpose columns for solvent…

  • Deactivated Fused Silica Tubing (Nonpolar)

    Restek

    Useful as guard columns, transfer lines, or long retention gaps Inertness-tested with the Grob test mix includes test chromatogram. 5-meter banded sections mounted in a Restek cage. Maximum temperature: 325°C Note: 30- and 60-meter lengths are banded in 5-meter sections. …

  • Rtx-1701 Columns (fused silica)

    Restek

    midpolarity Crossbond phase Rtx-1701 is one of the more popular stationary phases used in capillary GC. The mix of cyano and phenyl functional groups increases the polarity and offers a different elution order relative to less polar Rtx-1 or Rtx-5 columns. An Rtx-1701 column is ideal for…

  • Rtx-BAC1 Columns (fused silica)

    Restek

    proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…

  • FAMEWAX Columns (USP G16) (fused silica)

    Restek

    polar phase; Crossbond polyethylene glycol The elution order of polyunsaturated FAMEs on FAMEWAX columns is comparable to that on other Carbowax columns, but baseline resolution is achieved in significantly less time. Application-specific columns for FAMEs, specially tested with a FAME…

  • Rtx-VMS Columns (fused silica)

    Restek

    proprietary Crossbond phase Rtx-VMS columns offer lower bleed, better selectivity, and overall faster analysis for separating volatile organic compounds, such as those listed in U.S. EPA Method 8260B. The Rtx-VMS stationary phase is a highly stable polymer that provides outstanding analysis of…

  • Rxi-5Sil MS Columns (fused silica)

    Restek

    low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane Rxi fused silica capillary GC columns were designed specifically to be the best columns available, for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity. In addition to…

  • Rtx-BAC Plus 1 Columns (fused silica)

    Restek

    These application-specific columns for blood alcohol analysis baseline separate all critical compounds—including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol—in less than 2 minutes. Every Rtx-BAC Plus 1 and Rtx-BAC Plus 2 column is qualified with a…

  • Rtx-200 Columns (fused silica)

    Restek

    midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane Rtx-200 columns have accomplished many difficult separations not possible on any other bonded stationary phase. Many analysts consider these the best, most inert midpolarity columns available. The trifluoropropylmethyl polysiloxane…

  • ShinCarbon ST Columns

    Restek

    Analyze oxygen, nitrogen, methane, carbon monoxide, and carbon dioxide with one column at room temperature. ShinCarbon ST material, a high surface area carbon molecular sieve (~1,500 m 2 /g), is the ideal medium for separating gases and highly volatile compounds by gas solid chromatography (GSC).…

  • n-Octane on Res-Sil C Column (packed)

    Restek

    This packed column has unique selectivity for resolving unsaturated light hydrocarbons. Special Columns for Unsaturated Light Hydrocarbons Faster separations of C1 to C4 hydrocarbons. Res-Sil packing replaces Porasil materials.

  • Rtx-225 Columns (fused silica)

    Restek

    polar phase; Crossbond cyanopropylmethyl phenylmethyl polysiloxane The cyanopropyl-containing Rtx-225 phase is slightly less polar than bonded polyethylene glycol (PEG) phases, but it can be used for many of the same applications. Improvements to the Rtx-225 polymer have increased thermal…

  • Rtx-CLPesticides Columns (fused silica)

    Restek

    Column bleed, measured by ECD, is extremely low at temperatures up to 330°C, which is critical for baking-out the column to remove high-boiling compounds commonly found in pesticide/PCB extracts. An analysis time of less than 10 minutes improves throughput compared to other stationary phases. …

  • MXT-Biodiesel TG Columns (Siltek-treated stainless steel)

    Restek

    Fast analysis times and sharp mono-, di-, and triglyceride peaks. Stable at 430°C for reliable, consistent performance.

  • Rt-Alumina BOND/KCl Columns (fused silica PLOT)

    Restek

    Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or…