Gas Chromatography Columns

Compare Tool

Select up to 3 products

HomeAll Products

Agilent Technologies Columns Gas Chromatography Columns

1 - 32 of 110
Sort
View
Show
  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • DB-624

    Agilent Technologies

    Specifically designed for the analysis of volatile priority pollutants No cryogenics needed for U.S. EPA Method 502.2 Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240 and 8260 Exhibits inertness to active compounds Bonded and cross-linked Solvent…

  • Carbowax 20m And HP-20m

    Agilent Technologies

    Polyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M.

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • Press-Fit Capillary Column Connectors

    Agilent Technologies

    In the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the…

  • DB-ALC1 And DB-ALC2

    Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • UltiMetal Plus Flexible Metal Ferrules

    Agilent Technologies

    Put an end to frustration about GC capillary column connections! With the novel design of our proprietary UltiMetal Plus Flexible Metal ferrule, you can confidently make leak free column unions to capillary flow technology (CFT) devices. These new metal ferrules fix the problems of column breakage…

  • GS-Gaspro

    Agilent Technologies

    Bonded PLOT column technology Suitable for light hydrocarbons and sulfur gas Retention stability not affected by water Separates CO and CO2 on a single column Ideal PLOT column for CG/MS - no particles Temperature limits: -80° to 260°/300°C …

  • DB-Petro

    Agilent Technologies

    100% Dimethylpolysiloxane Configured for the analysis of petroleum process products PONA, PIANO High resolution Bonded and cross-linked Solvent rinsable Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1 100 psi regulator required to reach optimum…

  • DX-1 And DX-4

    Agilent Technologies

    DX-1: 90% Dimethylpolysiloxane - 10% Polyethylene Glycol DX-4: 15% Dimethylpolysiloxane - 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing.

  • DB-Wax

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity …

  • DB-17

    Agilent Technologies

    (50%-Phenyl)-methylpolysiloxane Midpolarity slightly more polar than HP-50+ Suitable for confirmational analyses Bonded and cross-linked Solvent rinsable Temperature limits are 40° to 260/280°C or 40° to 280/300°C Equivalent to USP Phase G3 HP-50+, Rtx-50, CP-Sil 24 CB, 007-17(MPS-50),…

  • DB-5 And DB-5ms

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-5 (2713R99, T86, T94 and V89) (5%-Phenyl)-methylpolysiloxane Non-polar …

  • HP-5ms Ultra Inert

    Agilent Technologies

    Agilent J&W HP-5ms Ultra Inert is specifically tested for inertness for active compounds, including acidic and basic compounds, to meet the worldwide drive for lower detection levels. With very low bleed characteristics, bonded and cross-linked HP-5ms Ultra Inert is solvent rinsable and ideal…

  • DB-VRX

    Agilent Technologies

    Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)** No subambient cooling required to…

  • Straight Ferrules

    Agilent Technologies

  • DB-1701p

    Agilent Technologies

    Low/midpolarity Exact replacement of HP-PAS1701 Specifically designed and processed for the analysis of organochlorine pesticides ECD tested to assure minimal pesticide breakdown and low ECD bleed Bonded and cross-linked Solvent rinsable Similar Phases: SPB-1701,…

  • HP-1

    Agilent Technologies

    100% Dimethylpolysiloxane Industry standard general purpose column Non-polar Wide range of applications Superior performance of low molecular weight alcohols High temperature limit Bonded and cross-linked Solvent rinsable Wide range of column dimensions …

  • HP-Voc

    Agilent Technologies

    • New Bullet • New Bullet • New Bullet • New Bullet • New Bullet • New Text

  • Deactivated Fused Silica Tubing

    Agilent Technologies

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness.

  • DB-1

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Non-polar Excellent general purpose column …

  • CAM

    Agilent Technologies

    Base deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing.

  • HP-1ms

    Agilent Technologies

    100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • Se-30 And Se-54

    Agilent Technologies

    SE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing.

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • Undeactivated Fused Silica Tubing

    Agilent Technologies

    Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical.

  • CP-Wax 58 FFAP CB Capillary Columns

    Agilent Technologies

    Agilent J&W CP-Wax 58 FFAP CB column is a nitroterephthalic acid-modified, chemically bonded polyethylene glycol phase. It is designed for the analysis of acidic compounds, such as phenols, and underivatized as well as derivatized free fatty acids. Nitroterephthalic acid-modified…

  • HP-Plot Q

    Agilent Technologies

    Bonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…