Cannon Instrument
-
High Viscosity Standards
Cannon InstrumentFor determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific
-
-
Viscometer Holder
Cannon InstrumentAll Cannon viscometer holders fit holes 51 mm (2 inches) in diameter. Rubber holders are made of neoprene rubber. Plastic holders are self-aligning and hold the viscometer firmly by means of a spring clip. Metal holders are also self aligning, and are constructed of chrome-plated machined brass.…
-
Flash Point Reference Materials
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
-
Zeitfuchs Cross-Arm Calibrated Viscometers
Cannon InstrumentCannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…
-
Cannon-Ubbelohde UBU And UBC Series
Cannon InstrumentUncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…
-
-
Bath Oil, 6-Gallon Container
Cannon InstrumentContains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.
-
Viscosity Standard, -20 and -25°C for CMRV, 500 ml
Cannon InstrumentFor preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST
-
Cannon Four Bulb Shear Dilution Viscometers
Cannon InstrumentFour Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…
-
TE-3000 Constant (Low) Temperature Bath
Cannon InstrumentFor glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
Pressure / Vacuum Pump, 120V, 60Hz
Cannon InstrumentInexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…
-
BS/U/M Miniature U-Tube
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…
-
Semi-Micro, Cannon CUSMC Series Viscometer
Cannon InstrumentCalibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…
-
Cold-Cranking Simulator Standards
Cannon InstrumentCANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).
-
Cannon-Fenske Series Viscometers
Cannon InstrumentCannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…
-
General Purpose Viscosity Standards
Cannon InstrumentBased on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…
-
Asphalt Institute Vacuum, Cannon Aivc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…
-
Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…
-
Paint Viscosity Standards
Cannon InstrumentFor Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.
-
CT-600 Constant Temperature Bath
Cannon InstrumentIdeal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of…
-
Kinematic Viscometers & Accessories
Cannon InstrumentThe Cannon Instrument probe is suitable for use with Dostmann dual channel digital thermometers for various viscometer models. You can choose ideal replacement part or accessory which ensures smooth functioning of thermometer units.
-
General Purpose Low Temperature Viscosity Standards
Cannon InstrumentCANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…
-
BS/IP/SL(S) Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…
-
Viscometer Calibration Size 200
Cannon InstrumentSimilar to Cannon-Manning Vacuum (CMV, 9724-H50) series, but with graduated capillary instead of two timing bulbs. Provided with certificate of calibration and instruction sheet. Viscosity range, poise: 2400 - 52000 Approx. constant poise/second at 300mm Hg Bulb B: 128 Approx.…
-
VISDISK for Windows
Cannon InstrumentPrograms are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…
-
Ink and Paint Viscosity Standards
Cannon InstrumentFor ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…
-
TE-1500 Constant (Low) Temperature Bath
Cannon InstrumentDesigned specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…
-
Large Vial
Cannon InstrumentThe Cannon Instrument large vial is an ideal accessory to have in any chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories.
-
CT-2000 Constant Temperature Bath
Cannon InstrumentMicroprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…