Cannon Viscosity Standards

Compare Tool

Select up to 3 products

Cannon Viscosity Standards
1 - 32 of 40
Sort
View
Show
  • … Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density values. 9727C35, C40 and C60 Viscosity Standards are also used for Saybolt viscosity determinations and include Saybolt viscosity values.

  • Silicone Viscosity Standards

    Cannon Instrument

    Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for water at 20°C (68°F). Silicone standards

  • Paint Viscosity Standards

    Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • High Viscosity Standards

    Cannon Instrument

    For determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific

  • … For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample volume: 1.0 mL.…

  • For use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…

  • Conform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles

  • …viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished with each standard.

  • Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and ISO…

  • CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • …Calibrated with Cannon viscosity standards traceable to NIST; Cannon standards are produced in accordance with ISO 90002 Each cup is furnished with the mathematical formula for calculating the viscosity in centistokes using efflux time measured, and with a table giving viscosity value…

  • CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • BS/U/M Miniature U-Tube

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • …of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two bulbs are incorporated to extend viscosity

  • …measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity determinations …

  • Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate…

  • CANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…

  • For preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST

  • Calibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…

  • Digital Paddle Viscometers

    Cannon Instrument

    …and 100°C Rugged and lightweight Most tests completed within 15 minutes Easy-to-use The CANNON Digital Paddle Viscometer has been designed to accurately measure the viscosity of asphalt emulsions, suspensions, marine fuels, residual oils, slurries, paints and similar materials …

  • Calibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…

  • Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…

  • High-Viscosity Std N2700000

    Cannon Instrument

    Dynamic Shear Rheometer (DSR) standard at 52, 58, 64, 70, &76°C is supplied in 55 mL bottles.

  • Flash Point Reference

    Cannon Instrument

    CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…

  • ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Routine Viscometers quickly and easily measure the viscosities of transparent Newtonian liquids. Sample volume: aprox. 7 ml. Precision: ±0.2%. With constant value indication at +40ºC and +100ºC. All…

  • …are supplied with the calibration certificate issued in accordance with the conditions of accreditation granted by a National Metrological Register which has assessed the measurement capability of the laboratory, the test uncertainty and its traceability to recognized international standards UKAS.

  • Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…

  • CBC Bath Coolers

    Cannon Instrument

    Thermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…

  • Designed specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…

  • …monitoring of bath temperature through built-in platinum resistance thermometer Meets ASTM D 445 requirements for measurements of kinematic viscosity at low temperatures Bath and calibration temperatures can be entered digitally on keypad. Non-volatile memory protects temperature data…

  • Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.