Cannon Viscosity Standards

Compare Tool

Select up to 3 products

Cannon Viscosity Standards
1 - 32 of 40
Related Categories: Viscosity Standard | Stormer Viscometer | Cannon | S60 | N4
Sort
View
Show
  • General Purpose Viscosity Standards

    Cannon Instrument

    … Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density values. 9727C35, C40 and C60 Viscosity Standards are also used for Saybolt viscosity determinations and include Saybolt viscosity values.

  • General Purpose Low Temperature Viscosity Standards

    Cannon Instrument

    CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • Paint Viscosity Standards

    Cannon Instrument

    For Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.

  • Cannon-Fenske Series Viscometers

    Cannon Instrument

    Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and ISO…

  • Ink and Paint Viscosity Standards

    Cannon Instrument

    …viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished with each standard.

  • Silicone Viscosity Standards

    Cannon Instrument

    Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for water at 20°C (68°F). Silicone standards

  • Cannon-Fenske Routine Capillary Viscometers

    Fungilab

    ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Routine Viscometers quickly and easily measure the viscosities of transparent Newtonian liquids. Sample volume: aprox. 7 ml. Precision: ±0.2%. With constant value indication at +40ºC and +100ºC. All capillary viscometers are…

  • Viscosity Standard, -20 and -25°C for CMRV, 500 ml

    Cannon Instrument

    For preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST

  • High Viscosity Standards

    Cannon Instrument

    For determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific

  • High-Temperature Viscosity Standards

    Cannon Instrument

    For use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…

  • Cold Cranking Simulator Viscosity Standards

    Cannon Instrument

    Conform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles

  • CT-2000 Constant Temperature Bath

    Cannon Instrument

    Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

  • Cannon-Manning Vacuum, Cannon CMVC Series Viscometers

    Cannon Instrument

    …of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two bulbs are incorporated to extend viscosity

  • Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers

    Cannon Instrument

    … For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample volume: 1.0 mL.…

  • Zeitfuchs Cross-Arm Unity Factor, Found Holder, ZCAXC-RO Series Viscometers

    Cannon Instrument

    Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…

  • Cold-Cranking Simulator Standards

    Cannon Instrument

    CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • Certified Viscosity “Check Oils” for SAE Target Viscosities

    Cannon Instrument

    CANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…

  • Thomas Zahn Signature Series S90 Viscosity Cups

    Thomas®

    …Calibrated with Cannon viscosity standards traceable to NIST; Cannon standards are produced in accordance with ISO 90002 Each cup is furnished with the mathematical formula for calculating the viscosity in centistokes using efflux time measured, and with a table giving viscosity value…

  • Semi-Micro, Cannon CUSMC Series Viscometer

    Cannon Instrument

    …measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity determinations …

  • Asphalt Institute Vacuum, Cannon Aivc Series Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…

  • Modified Koppers Vacuum, Cannon Mkvc Series Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…

  • Cannon Four Bulb Shear Dilution Viscometers

    Cannon Instrument

    Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…

  • High-Viscosity Std N2700000

    Cannon Instrument

    Dynamic Shear Rheometer (DSR) standard at 52, 58, 64, 70, &76°C is supplied in 55 mL bottles.

  • Flash Point Reference

    Cannon Instrument

    CANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…

  • Cannon-Ubbelohde UBU And UBC Series

    Cannon Instrument

    Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…

  • Cannon-Ubbelohde, CUU And CUC Series Viscometers

    Cannon Instrument

    Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…

  • CBC Bath Coolers

    Cannon Instrument

    Thermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…

  • BS/U/M Miniature U-Tube

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • TE-1500 Constant (Low) Temperature Bath

    Cannon Instrument

    Designed specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…

  • TE-3000 Constant (Low) Temperature Bath

    Cannon Instrument

    …monitoring of bath temperature through built-in platinum resistance thermometer Meets ASTM D 445 requirements for measurements of kinematic viscosity at low temperatures Bath and calibration temperatures can be entered digitally on keypad. Non-volatile memory protects temperature data…

  • BS/IP/MSL Miniature Suspended Level Viscometers

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of…

  • BS/IP/SL Suspended Level Viscometer

    Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…

Compare Tool

Select up to 3 products

Please Log In