Spectrophotometer For Water Analysis

Compare Tool

Select up to 3 products

Spectrophotometer For Water Analysis
1 - 26 of 26
Sort
View
Show
  • Thermo Scientific Orion

    …UV-Vis Spectrophotometer The Thermo Scientific* Orion AquaMate spectrophotometer offers accuracy, dependability and ease of use your lab requires. The compact design, intuitive operation and innovative features will ensure your lab will have the ideal instrument for water analysis and beyond.…

  • The spectrophotometer photoLab® 7600 UV-VIS combine routine analysis with spectral analysis and pioneering procedure OptRF. Menu-guided operation OptRF for standard parameters COD, NO3, NO2 in the outlet of municipal wastewater treatment plants Multi-layer AQA Application…

  • …bench-top spectrophotometer including Spectrum Scanning, Photometric, Quantitative and Kinetic methods. Due to its portable design, it is also ideal for field monitoring and on-site operations for water and soil analysis. Pre-programmed test methods including calibration data for the…

  • …one - one for all! photoLab® 7100 VIS of 320 – 1100 nm supports the fastest and affordable routine analysis via barcoded test kits for round and rectangular cuvettes. More than 250 methods are available for water analytics, galvanics and general lab analytics. Special procedures for

  • for use with test kits, complex kinetics or spectral measurements. The Spectroquant® Prove family is our series of cutting edge spectrophotometers for easy analysis of water, food and beverage, and environmental samples. All Spectroquant® Prove instruments are pre-programmed for over…

  • …UV/VIS spectrophotometer, optimized for sensitive measurements such as the analysis of drinking water and beverages. Programmed for over 180 reagent tests and free methods, capable of both UV and VIS measurements, and equipped with a long-lasting xenon lamp, Prove 300 is the ideal tool for rapid,…

  • for teaching and routine applications. For over half a century, laboratories around the world have relied on Thermo Scientific spectrophotometers for quick, easy measurements in water, quality control, clinical facilities, and in teaching laboratories. The new SPECTRONIC 200 spectrophotometer

  • water test kit methods • Access methods easily. Built-in features such as a favorite list and LongClick™ speed up routine analyses • Clean up quickly thanks to a washable drip tray Easy VIS provides an economic option for the spectrophotometric analysis using visible…

  • Persee Analytics

    … Integrated safety precautions for user protection, pressure sensor, flame sensor, leakage sensor, water sensor, high power protection etc. Precision accuracy with integrated correction system. Life cycle value, best choice for less than 8 elements of analysis. Transversal heating structure…

  • Persee Analytics

    … Integrated safety precautions for user protection, pressure sensor, flame sensor, leakage sensor, sequence control for ignition, burner identification, water sensor, high power protection, etc. Time-saving high speed analysis, support sequence program for quick testing. Transversal heating…

  • … The DPD Method References: USEPA Methods for Chemical Analysis of Water and Wastes, Method 330.5 (1983). APHA Standard Methods, 23rd ed., Method 4500-Cl G - 2000. Potassium iodide is added to the sample before analysis. Ozone reacts with the iodide to liberate iodine. The iodine…

  • …has been established for drinking water by the USEPA. The Cadmium Reduction Method References: ASTM D 3867-09, Nitrate-Nitrite in Water, Test Method B. APHA Standard Methods, 23rd ed, Method 4500-NO3-E-2016. USEPA Methods for Chemical Analysis of Water and Wastes, Method 353.3…

  • …has been established for drinking water by the USEPA. The Cadmium Reduction Method References: ASTM D 3867-09, Nitrate-Nitrite in Water, Test Method B. APHA Standard Methods, 23rd ed, Method 4500-NO3-E-2016. USEPA Methods for Chemical Analysis of Water and Wastes, Method 353.3…

  • …mg/L has been established by the USEPA for nitrite-nitrogen in drinking water. Azo Dye Formation Method References: APHA Standard Methods, 23 rd . ed., Method 4500-NO2 -?  B - 2000. USEPA Methods for Chemical Analysis of Water and Wastes, Method 354.1 (1983). …

  • …an orangecolored chelate with copper. The method measures total soluble copper as ppm (mg/L) Cu. The test kits are applicable for analysis of drinking water, surface waters, groundwater, wastewater and seawater. Range: V-2000: 0-12.00 ppm / Spec: 0-7.00 ppm Method: Bathocuproine …

  • …has been established for drinking water by the USEPA. The Cadmium Reduction Method References: ASTM D 3867-09, Nitrate-Nitrite in Water, Test Method B. APHA Standard Methods, 23rd ed, Method 4500-NO3-E-2016. USEPA Methods for Chemical Analysis of Water and Wastes, Method 353.3…

  • …Contaminant Level for free cyanide in drinking water is 0.2 mg/L. CHEMetrics’ cyanide test kits are applicable to the monitoring of effluents and surface water supplies. It is recommended, however, that the sample be distilled and hydrogen sulfide be removed prior to analysis. The…

  • water, goodquality nitrified wastewater effluent, and seawater. In some waters, calcium and magnesium concentrations can cause cloudiness of the reagent. Adding a few drops of stabilizer solution (Rochelle Salt) will prevent this cloudiness. References recommend distilling samples prior to analysis.

  • water, goodquality nitrified wastewater effluent, and seawater. In some waters, calcium and magnesium concentrations can cause cloudiness of the reagent. Adding a few drops of stabilizer solution (Rochelle Salt) will prevent this cloudiness. References recommend distilling samples prior to analysis.

  • Mettler Toledo

    Simplify Performance Verification Performance Verification for UV/VIS Excellence spectrophotometers is simply automated with CertiRef™. Compliance with regulations has never been so easy. The performance checks with certified reference materials can be started with One Click and are…

  • …drinking water analysis using Hach Method 8021 Sample Size: 10 mL Range: up to 2.00 mg/L Contains 1 Refill Vial with enough reagent for 250 Tests Backed by over 20 years of DPD experience! For best results use with a Hach colorimeter or spectrophotometer.

  • …multi-well spectrophotometer (ELISA reader). The measured absorbance directly correlates to the number of viable cells. Cell proliferation and viability assays are of particular importance for routine applications in cell biology. Tetrazolium salts (e.g., MTT, XTT, WST-1) are particularly useful for

  • …Colorimeter, and the SP600 Spectophotometer. These easy-to-use reagents for water analysis offer an extended shelf life. They can also be used in other manufacturer's spectrophotometers, colorimeters and test kits . Why pay more for the same results? Lovibond will stand behind the comparability…

  • …cells in the culture. Other Notes: For life science research only. Not for use in diagnostic procedures. Preparation Note: Working solution: Preparation of solutions Thaw XTT labeling reagent and electron-coupling reagent, respectively in a water bath at 37 °C. Mix each vial…

  • …will provide accurate results with Lovibond and other manufacturer’s spectrophotometers, colorimeters and test kits. Lovibond Powder Pack Reagents are: US EPA accepted for reporting drinking water analysis Easier to Handle -- Our design is 37% larger than the competition…