BioAssay Systems

Compare Tool

Select up to 3 products

HomeAll Products

BioAssay Systems

1 - 32 of 181
Sort
View
Show
  • BioAssay Systems

    For quantitative determination of phosphatase activity The detection limit is generally 3 ng phosphatase or below. No wash or reagent transfer steps are involved. All reagents are compatible with high-throughput liquid handling instruments. Method: OD405 nm. Samples: Protein phosphatases.

  • For quantitative determination of lactate dehydrogenase LDH activity and screen/evaluation of LDH modulators High sensitivity and wide linear range. Use 3 μL serum or plasma sample. The detection limit is 2 U/L, linear up to 200 U/L Homogeneous and simple procedure. Simple…

  • For quantitative determination of glucose oxidase activity and evaluation of drug effects on its metabolism. Linear detection range 0.02 to 10 U/L glucose oxidase for colorimetric assays and 0.002 to 1.5 U/L for fluorimetric assays. Homogeneous high-throughput assay. Method: OD570 nm,…

  • For quantitative determination of urease activity and evaluation/screen for urease inhibitors. Safe. Non-radioactive assay. As low as 0.003 U/L urease activity can be quantified. This "mix-incubate-measure" type assay can be readily automated to process thousands of samples…

  • For quantitative determination of cholesterol and evaluation of drug effects on cholesterol metabolism. Linear detection range 5 - 300 mg/dL cholesterol in 96-well plate assay. Convenient. Room temperature assay. No 37°C heater is needed. Can be readily automated to process…

  • For quantitative determination of hemoglobin (Hb) in whole blood. Safe. No hazardous chemicals (e.g. potassium cyanide in Drabkin’s Reagent) used. The "mix-and-read" procedure involves addition of a single reagent and reading the optical density. Can be readily automated…

  • For quantitative determination of L-lactate (L-lactic acid) and evaluation of drug effects on its metabolism. Linear detection range 0.05 - 2 mM L-Lactate in 96-well plate assay. Convenient room temperature assay. No 37°C heater is needed. Can be readily automated to process…

  • For quantitative determination of lipase activity. Linear detection range 40 to 1600 U/L lipase activity in 96-well plate assay. Can be automated to process thousands of samples per day. Method: OD412nm. Samples: Serum, plasma, saliva, urine etc.

  • Direct determination of formate concentrations in biological (e.g. urine, blood, etc.) and other samples. Linear detection range 0.050 to 5 mM Formate. Convenient room temperature assay. No 37°C heater is needed. "Add-mix-read" type high-throughput assay. Method: OD565…

  • For quantitative determination of β-glucosidase activity and evaluation of drug effects on its metabolism. High sensitivity and wide linear range. Use 20 μL sample. The detection limit is 2 U/L, linear up to 250 U/L. Homogeneous and simple procedure. Simple…

  • β-N-Acetylglucosaminidase activity determination in biological samples. Linear detection range 0.2 - 50 U/L β-N-acetylglucosaminidase. Homogeneous "mix-incubate-measure" type assay Can be readily automated to process thousands of samples per day. Method: OD405 nm.…

  • For quantitative determination of hemoglobin and evaluation of drug effects on hemoglobin metabolism. Safe. Reagents are non-toxic. Linear detection range 0.9 - 200 mg /dL hemoglobin. The "mix-and-read" 5 minute procedure. Can be readily automated to process tens of…

  • For quantitative determination of alanine transaminase activity. Linear detection range 2-100 U/L. Assay can be carried out in a microplate or a cuvette and takes only 10 min. Method: OD340 nm. Samples: Serum, plasma etc.

  • For quantitative determination of urinary protein and creatinine concentrations (protein/creatinine ratio, UPCR). Linear detection range 1 - 20 mg/dL Protein and 1 – 150 mg/dL Creatinine. Fast and convenient. No sample pre-treatment is needed. Simple "Mix-incubate-read"…

  • For quantitative determination of glucose and evaluation of drug effects on glucose metabolism. Linear detection range 0.7 mg/dL (39 μM) to 300 mg/dL (16.6 mM) glucose. The procedure involves addition of a single working reagent and incubation for 8 min in a boiling water bath. Low…

  • For quantitative determination of total antioxidant capacity (TAC) and evaluation of drug effects on TAC metabolism. Linear detection range from 1.5 to 1000 μM Trolox. The procedure involves addition of a single working reagent and incubation for 10 min. Can readily automated to…

  • For quantitative determination of reduced glutathione (GSH) and evaluation of drug effects on glutathione metabolism. Linear detection range 0.4 - 100 μM in 96-well plate. Low interference. Amino acids and common buffers do not interfere. Method: OD412nm. Samples: Whole blood,…

  • For quantitative determination of α-mannosidase enzyme activity using a p-nitrophenol based substrate. Fast and sensitive. Linear detection range (10 μL sample): 1 to 250 U/L for a 10 minute reaction. Convenient and high-throughput. Homogeneous "mix-incubate-measure"…

  • For quantitative determination of glutamine and evaluation of drug effects on glutamine metabolism. Linear detection range 0.023 - 2 mM glutamine in 96-well plate assay. Convenient room temperature. No 37°C heater is needed. Can be readily automated to process thousands of samples…

  • For quantitative determination of heme and evaluation of drug effects on heme metabolism. Safe. Reagents are non-toxic. Linear detection range 0.6 - 125 μM heme. The "mix-and-read" 5 minute procedure. Can be readily automated to process tens of thousands of samples per…

  • For quantitative determination of phosphate and evaluation of drug effects on phosphate metabolism. Linear detection range 0.3 - 50 μM (0.0028 - 0.47 mg/dL) phosphate in 96-well plate assay. Can readily automated for processing thousands of samples per day. Method: OD620 nm. …

  • For quantitative determination of albumin. Use as little as 5 μL samples. Detection range 0.01 - 5 g/dL (1.5 - 750 μM) albumin in 96-well plate assay. Can be readily automated to assay thousands of samples per day. Method: OD620 nm (BCG). Samples: Serum, plasma, urine,…

  • To be used as a cytotoxic control agent in the CellQuanti-BlueTM and CellQuanti-MTTTM Cell Viability Assay Kits IC50 = 0.002 wt%. Kit size: (50mg) tests Shelf life: 12 months Shipping: ambient temp storage: 4°C

  • For quantitative bioluminescent assay for ADP:ATP ratio (apoptosis) in cells. Safe. Non-radioactive assay. Homogeneous and convenient "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: Luminescence. Samples: Cells.

  • For quantitative determination of reduced and oxidized glutathione (GSH/GSSG). Linear detection range 0.01-3 µM GSH equivalents. Method: OD412nm. Samples: Whole blood, plasma, serum, urine, tissue and cell extracts.

  • For quantitative determination of glucose-6-phosphate in biological samples. Linear detection range 10 to 1000 μM G6P. Homogeneous "mix-incubate-measure" type high-throughput assay. Method: OD460 nm. Samples: Plasma, serum, tissue and culture media etc.

  • BioAssay Systems

    For quantitative determination of DNA. Linear detection range 2 - 40 ng (100 - 2,000 ng/mL) calf thymus DNA in 96-well plate assay. Convenient. Single working reagent. Can readily automated to test tens of thousands of samples per day. Low interference. RNA, salt (up to 3M NaCl),…

  • For quantitative determination of uric acid and evaluation of drug effects on uric acid metabolism. Linear detection range 0.22 -30 mg/dL (13 - 1785 μM) uric acid in 96-well plate assay. Can be readily automated to process thousands of samples per day. Method: OD590 nm. Samples:…

  • Homogeneous assay for cell viability, proliferation, cytotoxcity and evaluation of anticancer agents Safe. Non-radioactive assay (cf. 3H-thymidine incorporation assay) Sensitive and accurate. As low as 950 cells can be accurately quantified Fast. High-throughput assay using 96-well…

  • For quantitative determination of alkaline phosphatase (ALP) activity using stable p-nitrophenol phosphate substrate. High sensitivity and wide linear range. Use 5 μL serum or plasma sample. The detection limit is 2 U/L, linear up to 800 U/L. Homogeneous and simple procedure. Simple…

  • For quantitative determination of L-phenylalanine and evaluation of drug effects on its metabolism. Safe. Non-radioactive assay. Linear detection range of 2 - 300 μM L-phenylalanine. Can be readily automated to test thousands of samples per day. Method: FL530/595 nm. Samples:…

  • For quantitative determination of ascorbate (ascorbic acid) and evaluation of drug effects on ascorbic acid metabolism. Linear detection range colorimetric assay 6 to 1000 μM, fluorimetric assay 1 to 100 μM ascorbic acid. Method: OD570 nm, or FL530/585 nm. Samples: Serum, plasma,…

Compare Tool

Select up to 3 products