YMC

Compare Tool

Select up to 3 products

1 - 32 of 157
Sort
View
Show
  • C8 is the most commonly used column type following C18. YMC Octyl columns are prepared from exhaustive bonding of a monomeric octylsilane to totally spherical and porous silica gels. The functionalized silica is then treated with a endcapping process. Application: For Anti-Human Immunodeficiency…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

  • ODS-A in 120Å pore size is the first choice of many chromatographers for high performance reversed phase separations. It has selectivity for the separation of a wide range of organic compounds found in pharmaceutical, chemical and biotechnology industries. ODS-A is a high coverage, fully endcapped…

  • Meteoric Core products feature ultra fast separation and outstanding resolution, excellent peak shape on basic and coordination compounds, a wide usable pH range, and a low column bleed.

  • Pro C18 RS has excellent peak shape for the separation of basic compounds because of high quality end capping. Pro C18 RS has high recognition of stereoselectivity because of high carbon polymeric type bonding. Pro C18 RS can be used over a wide pH range (1-10) to aid in method development. High…

  • YMC-Actus series are semi-preparative HPLC columns that have excellent column durability and efficiency by applying axial compression technology. YMC-Actus series columns show high durability under high flow rate or steep gradient conditions and desirable for milligram scale preparative HPLC of…

  • YMC-Pack Diol is a size exclusion chromatography column utilizing a silica gel base. Diol-120, 200, and 300 are suitable for separation or molecular weight determination of proteins with molecular weights of 10,000 to 1,000,000. Diol-60 is the most suitable for separation of peptides of…

  • ODS-AM is a high carbon load C18 packing that is similar in selectivity to ODS-A. The major difference between these bonded phases is that ODS-AM has extremely tight specification criteria which provides excellent peak shape and more reproducible separation. Application: For Alkaloids Long-term…

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers can be realized effectively. Enantiomeric separation is achieved from the various diastereomeric interactions such as hydrogen bonding,…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • YMC-Triart C18 is a hybrid silica-based ODS column emphasizing durability, low operating pressure, and excellent performance. YMC-Triart C18 has been developed and is manufactured using state-of-the-art technologies that define materials, granulation, and surface modification. Application: For…

  • YMC-Pack TMS columns are bonded with trimethylmonochlorosilane to create a phase with intermediate polarity for analysis of extremely hydrophobic compounds using conventional reversed-phase solvents and highly polar compounds using highly aqueous solvents. The unique chemistry of TMS is also…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • YMC America column coupler is a single- and double-end connector. Stainless tube 50 mm×1, male nut×2, ferrule×2)

  • YMC-Pack C4 (Butyl) columns are less hydrophobic than C8 or C18 packings, and generally utilize more aqueous eluents than either of these reversed phase column types. When compared to C8 and C18 columns using the same eluent, C4 columns show significantly shorter retention for non-polar compounds.…

  • Pro C18 RS has excellent peak shape for the separation of basic compounds because of high quality end capping. Pro C18 RS has high recognition of stereoselectivity because of high carbon polymeric type bonding. Pro C18 RS can be used over a wide pH range (1-10) to aid in method development. …

  • YMC-Pack PVA-Sil, bonded with a monomolecular polymer coating of vinyl alcohol (PVA), completely covers both external and internal surfaces of the silica support, protecting it against aggressive, high pH buffers and solvents. The PVA polymer shell on PVA-Sil deactivates the silica support while…

  • YMC-Pack Diol is a size exclusion chromatography column utilizing a silica gel base. Diol-120, 200, and 300 are suitable for separation or molecular weight determination of proteins with molecular weights of 10,000 to 1,000,000. Diol-60 is the most suitable for separation of peptides of…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • YMCbasic is a unique reversed-phase column designed for analysis of pharmaceuticals and other basic compounds. YMCbasic utilizes a novel silica synthesis and state-of-art silane bonding to create a column which gives true reversed-phase character, high resolution and excellent peak shape for the…

  • The hydrophobicity of YMC-Pack C8 is moderate for a reversed-phase packing material. Retention times of samples on YMC-Pack C8 tend to be shorter than those on ODS stationary phase. The moderate hydrophobicity of YMC-Pack C8 makes it useful for separating samples with relatively high…

  • SUMICHIRAL OA columns are high-performance chiral columns for enantiomer separation by HPLC. On SUMICHIRAL OA columns direct separation of various enantiomers can be realized effectively. Enantiomeric separation is achieved from the various diastereomeric interactions such as hydrogen bonding,…

  • The YMC-Pack C4 stationary phase surface hydrophobicity is lower than that of both ODS and C8 Retention times of samples on YMC-Pack C4 therefore tend to be shorter than those on ODS or C8. Separation characteristics of YMC-Pack C4 also differ from those of ODS. YMC-Pack C4 achieves better…

  • YMC-Triart C8 is a versatile column with excellent chemical durability that is equivalent to YMC-Triart C18. YMC-Triart C8 is suitable for fast analysis of samples containing hydrophobic compounds that are strongly retained on C18 columns or samples containing compounds with large differences in…

  • All phases in the Pro-family are ideal for the analysis of all types of organic molecules but specifically basic and metal chelating compounds. The ultrapure silica and very low residual silanol activity means that these columns frequently do not require the use of ion-pairing reagents or…

  • The choice of columns for analysis of difficult compounds by HPLC YMC-Pack Pro C18 columns start with a tightly controlled, highly purified silica gel, followed by a high-coverage C18 bonding and finish with a unique endcapping procedure utilizing Lewis acid-Lewis base chemistry. 2 µm particle size…

  • ODS-AQ is a unique reversed-phase material with both a hydrophobic high carbon loading and a relatively hydrophilic surface. Because of the hydrophilic surface, ODS-AQ can be "wetted" with polar eluents. ODS-AQ provides chromatographers reproducible retention and excellent peak shape in highly…

  • In a reversed-phase mode, Cyano columns are the most polar and least retentive of all reversed-phase packings. Extremely hydrophobic compounds, which do not elute on standard C18 and C8 packings with typical reversed-phase eluents, can be chromatographed using Cyano columns. In addition, the unique…

  • ODS-A in 120Å pore size is the first choice of many chromatographers for high performance reversed phase separations. It has selectivity for the separation of a wide range of organic compounds found in pharmaceutical, chemical and biotechnology industries. ODS-A is a high coverage, fully endcapped…

  • YMC-Pack NH2 is a normal-phase separation column utilizing the polarity of primary amino groups. It is also applicable to separations utilizing weak anion exchange. YMC-Pack NH2 is often used for separation of sugars. Application: For Nucleotides Silica gel chemically bonded with aminopropyl…

  • The high purity silica found in YMC-Pack Silica columns provides virtually complete sample recovery. The absence of silica impurities reduces non-specific sample adsorption which lowers sample recovery and may cause unusual peak shapes. The totally porous nature of the silica found in YMC-Pack…

Compare Tool

Select up to 3 products