PerkinElmer ICP-MS Spray Chambers
-
The Single Cell Application Module within PerkinElmer’s Syngistix ™ for ICP-MS software is the ideal tool for laboratories analyzing metal content in cells, either from bioaccumulation of metals or metallic nanoparticles in solution or measuring the intrinsic metal content of the cell. This unique…
-
The drain line kit includes a 1/4-28 spray chamber fitting with attached 32 cm line, as well as additional 0.75 mm I.D. Santoprene MPP tubing (double grey marked).
-
This 47 mL barrel spray chamber, made of perfluoroalkoxy alkanes (PFA), is hydrofluoric acid-resistant. It is designed to provide high sensitivity for semiconductor and other high purity applications.
-
The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…
-
The baffled micro cyclonic spray chamber, made of quartz, is designed for soil FAST and other aqueous applications. It features a secure, leak-free threaded drain port, o-ring-free connections to the nebulizer and torch injector, internal baffle, and threaded auxiliary port for gas addition. Micro…
-
The Cinnabar spray chamber is a mini-cyclonic spray chamber which gives good sensitivity at very low uptakes. The Cinnabar's design and low volume is ideal for the reduction of memory and matrix effects and very fast washout. It does not include an internal baffle and is not hydrofluoric…
-
This large Viton o-ring is for use with hydrofluoric acid-resistant Ryton Scott spray chambersin ELAN 5000, 6x00, 9000, and DRC-e ICP-MS series instruments.
-
The spray chamber's gas ports designed to be used with any addition gas. The spray chamber provides low blanks.
-
-
The quartz baffled cyclonic spray chamber features a 7 mm internal baffle, drain line, and injector connection. It's designed for all-purpose, non-hydrofluoric acid applications. The spray chamber provides excellent sensitivity, stability and low blanks.
-
This replacement locking clip is for the torch module mounting block (N0770600) used with Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV and 8x00 ICP-OES series instruments.
-
The 47 mm I.D. M100 spray chamber, made of perfluoroalkoxy alkanes (PFA), is an all-purpose, hydrofuloric acid-resistant spray chamber. The spray chamber features a barrel design and doesn't include an addition gas port.
-
The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…
-
The baffled, cyclonic, jacketed Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is…
-
The Scott spray chamber is made from corrosion-resistant material, which is inert to most mineral acids including hydrofluoric acid, aqua regia and all organic solvents normally used in ICP analyses. The Scott-type design minimizes pulsations from the peristaltic pump. The Type II, two-piece design…
-
This PTFE-coated Viton o-ring, with an inner diameter of 6.07 mm and width of 1.78 mm, is used for the internal injector support adapter with ELAN 6000, 9000, DRC II, and DRC-e, and NexION 300 and 350 ICP-MS series instruments.
-
Secures nebulizer to spray chamber.
-
This spray chamber Helix locking screw is used with ELAN 6000, 9000, DRC II, and DRC-e ICP-MS series instruments.
-
The baffled micro cyclonic spray chamber, made of quartz, is designed to deliver the fastest washout for concentrated samples or carryover-prone analytes in non-hydrofluoric acid samples. It features o-ring-free connections to the nebulizer and torch injector, secure, leak-free threaded drain port,…
-
An organics addition gas line is included in the Organics Sample Introduction Kit (N8150031).
-
The unbaffled cyclonic spray chamber, made of quartz, is designed for use with FAST DXi for all-purpose, high-purity applications for non-hydrofluoric acid samples. It provides excellent sensitivity, stability and low blanks.
-
This torch module mounting block is a sample introduction component used with Optima ™ 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV and 8x00 ICP-OES series instruments.
-
The dual baffled cyclonic spray chamber provides improved precision and low blanks. Hydride gas port for use with hydrideFAST or with any additional gas.
-
Type II Spray Chamber
PerkinElmerThe two-piece design ensures leak-free performance. The removable inner tube allows the chamber to be easily disassembled for cleaning, and the Ryton construction provides maximum corrosion resistance.
-
The PFA kit is an ultra-pure, HF-resistant introduction system for the Optima. All wetted surfaces are PTFE-coated PFA or sapphire. It is used by a majority of semiconductor labs worldwide for the analysis of semiconductor-grade chemicals and other high-purity chemicals. Benefits: Easy…
-
The baffled, cyclonic Twister spray chamber has a central transfer tube, which acts as a secondary particle separator, helping separate larger aerosol particles from the sample. This reduces solvent load in the plasma without compromising detection limits. The position of the baffle is carefully…
-
The quartz baffled cyclonic spray chamber features a 7 mm internal baffle, auxiliary gas port, drain line, and injector connection. It's designed for all-purpose, non-hydrofluoric acid applications. The spray chamber provides excellent sensitivity and stability with low background.
-
The Ryton Scott Spray Chamber is made from corrosion resistant Ryton, which is inert to most mineral acids including hydrofluoric acid, aqua regia and all organic solvents normally used in ICP analyses. The Scott-type design minimizes pulsations from the peristaltic pump. The Type II, two-piece…
-
This cyclonic spray chamber adaptor is used with Optima 2x00 DV, 4x00 DV, 5x00 DV, 7x00 DV, and 8x00 ICP-OES series instruments.
-
The Ryton Scott Spray Chamber is made from corrosion resistant Ryton, which is inert to most mineral acids including hydrofluoric acid, aqua regia, and all organic solvents normally used in ICP analyses. The Scott-type design minimizes pulsations from the peristaltic pump. The Type II, two-piece…
-
This baffled micro cyclonic spray chamber, made of quartz, is designed for all-purpose, non-hydrofluoric acid applications. The spray chamber provides excellent washout, sensitivity, stability and low blanks.
-
The PC 3X is a compact, Peltier-heated or cooled inlet system which incorporates the ESI cyclonic spray chamber. In cooling mode the PC 3X heats or cools the outer walls of the cyclonic spray chamber, reducing the water or solvent vapor loading on the plasma, resulting in enhanced stability and…