Agilent Technologies Gas Chromatography Columns
Agilent Technologies
Efficient LC Solutions that deliver the fast, reproducible results you need
-
GC Capillary Column
Agilent TechnologiesThe J&W DB-624 capillary Gas Chromatography (GC) column is designed for the analysis of volatile organic pollutants by GC and GC/MS. The DB-624 column is recommended for residual solvent analysis by USP Monograph , and Environmental Protection Agency (EPA) methods for volatile organic compounds…
-
GS-Alumina
Agilent TechnologiesMost “polar” Alumina phase Aluminum oxide with proprietary deactivation Excellent general use column for light hydrocarbon analysis: C1 to C8 hydrocarbon isomers Separates C1-C4 saturated and unsaturated hydrocarbons Best for resolving cyclopropane from propylene …
-
DB-5
Agilent Technologies(5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…
-
Deactivated Fused Silica Tubing
Agilent TechnologiesDeactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness. Agilent Technologies products are intended for…
-
DB-35ms
Agilent TechnologiesVirtually equivalent to a (35%-Phenyl)-methylpolysiloxane Midpolarity Very low bleed characteristics Extended temperature limit of 340/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Bonded and cross-linked Solvent rinsable …
-
DB-ALC1 And DB-ALC2
Agilent TechnologiesMeets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …
-
GC Capillary Guard Column
Agilent TechnologiesJ&W DB-5ms is a non-polar phenyl arylene polymer gas chromatography (GC) Column, virtually equivalent to (5%-phenyl)-methylpolysiloxane, featuring an excellent signal-to-noise ratio for analytical applications. This improved performance gives better sensitivity and mass spectral integrity, and…
-
DB-225
Agilent Technologies(50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…
-
HP-1ms
Agilent Technologies100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low bleed characteristics General purpose column Improved signal-to-noise ratio for better sensitivity and mass spectral integrity Bonded and cross-linked Solvent rinsable Temperature range:…
-
Ultimate Unions
Agilent TechnologiesExtend the life of your analytical GC or GC/MS column by using a guard column reliably connected to you analytical column with our high performance capillary GC column connector, the Ultimate Union. New-technology Ultimate Union kits eliminate the “arts and crafts” involved in…
-
DB-1701
Agilent Technologies(14%-Cyanopropyl-phenyl)-methylpolysiloxane Low/midpolarity Bonded and cross-linked Solvent rinsable Exact replacement for HP-1701 Similar Phases: DB-1701: SPB-1701, CP-Sil 19 CB, Rtx-1701, BP-10, OV-1701, 007-1701, ZB-170 Agilent Technologies products are intended for…
-
Select PAH Capillary Columns
Agilent TechnologiesAgilent J&W Select PAH is the first capillary column that provides a single solution for PAH analysis by separating all the isomers, thereby avoiding false positives and inaccurate results. It provides easy, fast, and accurate quantification of PAHs in environmental and food samples by…
-
DB-624
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…
-
HP-Plot Q
Agilent TechnologiesBonded polystyrene-divinylbenzene based column A PLOT column with polarity between Porapak-Q and Porapak-N Column for C1 to C3 isomers and Alkanes to C12, CO2 , methane, air/CO, oxygenated compounds, sulfur compounds and solvents A PLOT column to replace packed…
-
DB-225ms
Agilent TechnologiesVirtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…
-
HP-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly less polar than DB-35 Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, DB-35,…
-
CAM
Agilent TechnologiesBase deactivated polyethylene glycol Specifically designed for amine analysis Excellent peak shape for primary amines Replaces HP-Basicwax Similar Phases: Stabilwax-DB, Carbowax Amine Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. …
-
GC Columns Ferrules
Agilent TechnologiesThe Agilent Technologies ferrule is compatible for use with GC (gas chromatography) columns. It is mainly used to safeguard columns and maintain leak proof connections during high temperature applications. This accessory is made of sturdy material which offers enhanced durability. This product is…
-
HP-INNOWax GC Columns
Agilent TechnologiesHP-INNOWax is a polyethylene glycol (PEG) stationary phase that features high polarity and high upper temperature limits. It is a close equivalent to USP phase G16 and is targeted at food, flavor, and fragrance applications. The improved line of Agilent J&W HP-INNOWax GC columns utilizes…
-
DB-35
Agilent Technologies(35%-Phenyl)-methylpolysiloxane Midpolarity - slightly more polar than HP-35 Low bleed Inert to active solutes Ideal for confirmational analyses Bonded and cross-linked Solvent rinsable Equivalent to USP Phase G42 Similar Phases: Rtx-35, SPB-35, AT-35,…
-
GS-Carbonplot
Agilent TechnologiesAgilent J&W GS-CarbonPLOT uses a high stability, carbon-layer stationary phase to deliver unique selectivity for inorganic and organic gases. The column features an extended temperature limit to 360 °C. The retention stability of GS-CarbonPLOT is not affected by water, and the column is…
-
HP-1ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Identical selectivity to HP-1 Non-polar Low…
-
Se-30 And Se-54
Agilent TechnologiesSE-30: 100% Dimethylpolysiloxane SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
DB-210
Agilent Technologies(50%-Trifluoropropyl)-methylpolysiloxane High polarity Excellent for U.S. EPA Methods 8140 and 609 Bonded and cross-linked Solvent rinsable Exact replacement of HP-210 Close equivalent to USP Phase G6 Similar Phases: SP-2401 Agilent Technologies products…
-
Gas Chromatography Capillary Column
Agilent TechnologiesAgilent J&W VF-1ms is a highly inert, nonpolar, 100% dimethylpolysiloxane phase column that provides increased sensitivity for a broad array of applications, particularly for energy, pharmaceutical, and environmental analysis. The column has an ultra-low-bleed specification of 1 pA at 325 °C (30 m,…
-
DB-35ms Ultra Inert Columns
Agilent TechnologiesAgilent J&W DB-35ms Ultra Inert is a mid-polar column, for applications where different selectivity is needed for enhanced separations, including pesticide analysis and drugs of abuse testing. DB-35ms Ultra Inert quantifies components at a lower level, with broader linearity and optimized…
-
DB-FFAP
Agilent TechnologiesNitroterephthalic acid modified polyethylene glycol High polarity Designed for the analysis of volatile fatty acids and phenols Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 Temperature limits: 40° to 250°C NOTE: Agilent does…
-
GC Capillary Column
Agilent TechnologiesAgilent J&W DB-1 is nonpolar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, crosslinked and solvent rinsable, and is equivalent to USP phase G2. This product is…
-
HP-Ms
Agilent TechnologiesGC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. (5%-Phenyl)-methylpolysiloxane Identical selectivity to HP-5 Non-polar …
-
HP-5ms
Agilent TechnologiesMeets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…
-
Undeactivated Fused Silica Tubing
Agilent TechnologiesUndeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Agilent Technologies products are intended for sale/shipment within the US only. International customers…
-
DB-Waxetr
Agilent TechnologiesPolyethylene glycol (PEG) Extended Temperature Range (etr) High polarity Excellent column-to-column repeatability Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G16 Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52 CB, SUPEROX II, CB-WAX,…