PerkinElmer Gas Chromatography Columns
-
-
-
-
Elite-Siltek Guard, 5m x 0.32mm
PerkinElmerElite-Siltek Guard Columns lengthen the life of the capillary columns.
-
-
The Elite-Betacydex Columns for chiral separations that are 30 m long and have an inner diameter of 0.25 mm.
-
Elite-5MS capillary column 20m x 0.18mm, 0.18µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Elite-1 capillary column, 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-5MS capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -60oC to 350 oC Equivalent to USP G27, G36 phases
-
Elite-200 capillary column 60m x 0.32mm, 1.00µm
PerkinElmerEquivalent to USP G6 phase. Temperature range -20°C to 290/310°C.
-
Elite 1301 capillary column 30m x 0.25mm, 0.25µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
Temperature range: -20 to 320 degrees celsius. Similar to USP G43 phase.
-
-
Temperature range -60°C to 320/340°C.
-
Elite 1301 capillary column 10m x 0.18mm, 0.40µm
PerkinElmerTemperature range -20°C to 280°C Equivalent to USP G43 phase
-
The PerkinElmer Elite-502.2 Series of capillary columns are specifically designed for the analysis of volatiles by US EPA method 502.2. The low polarity phase is a proprietary dimethyl-diphenyl polysiloxane bonded phase.
-
Elite-17 capillary column, 20m x 0.18mm, 0.18µm
PerkinElmerEquivalent to USP G3 phase Temperature range 40°C to 320°C
-
Temperature range -60°C to 300/315°C.
-
Elite 624 capillary column 60m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Our new line of Velocity fused silica columns yield exceptional performance for general Gas Chromatography (GC) applications without the cost associated with gas chromatography and mass spectrum analysis. PerkinElmer Velocity columns are excellent for standard daily test applications. They combine…
-
Temperature range -60°C to 300/315°C.
-
Elite-5ht capillary column 30m x 0.25mm, 0.10µm
PerkinElmerTemperature range -60 o C to 400 o C. Equivalent to USP G27, G36 phases.
-
Deactivated Tubing is perfect for making guard columns and retention gaps. Use Splitters(p/n N9303448) and connectors (p/n N9302149) to attach tubing to polymide coated columns.
-
Empty Columns for all your Gas Chromatography equipment come in multiple sizes and are able to fit a variety of different systems.
-
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
-
Elite-1 capillary column, 15m x 0.25mm, 0.10µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-
Elite-35ms capillary column 25m x 0.20mm, 0.33µm
PerkinElmerEquivalent to USP G42 phase Temperature range 40°C to 340°C/360°C
-
Elite 624 capillary column 30m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Elite-1MS capillary column, 30m x 0.25mm, 0.25µm
PerkinElmerEquivalent to USP G1, G2 and G38 phases Temperature range -60°C to 350/400°C
-