Columns

Compare Tool

Select up to 3 products

1 - 32 of 242
Sort
View
Show
  • SampliQ Silica C18 ODS SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 24% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • Poroshell 120 HPLC Columns 

    Agilent Technologies

    Sub-2 µm-like high efficiency At ~40-50% lower pressure 2.7 µm particle size A "standard" frit to reduce potential clogging The particle has a solid core (1.7 µm) and porous outer layer (1.0 µm with a 0.5 µm diffusion path) Poroshell 120…

  • SampliQ QuEChERS Kits

    Agilent Technologies

    Extraction salts are pre-measured and provided in anhydrous packets, so you can conveniently add them after the acetonitrile and improve results Kits available with ceramic homogenizers to facilitate sample homogenization and to break up salt agglomerates more efficiently than shaking by hand;…

  • ZORBAX Capillary and Nano Columns

    Agilent Technologies

    Highest sensitivity for your smallest sample sizes Compatible with all LC/MS interfaces Internal diameters of 0.5, 0.3, 0.1, and 0.075 mm Packings/phases for both small and large molecules (80Å and 300Å pore sizes, respectively) Ideal for 1-D and 2-D (proteomics)…

  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • SampliQ Silica Si-SAX (Strong Anion Exchange) SPE Cartridges

    Agilent Technologies

    Ion Exchange Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional bonding process provides more stability over monomeric bonding Manufactured to Agilent’s rigorous quality standards in the…

  • SampliQ Silica Si-SCX (Silica Strong Cation Exchange) SPE Cartridges

    Agilent Technologies

    Ion Exchange Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional bonding process provides more stability over monomeric bonding Manufactured to Agilent’s rigorous quality standards in the…

  • Press-Fit Capillary Column Connectors

    Agilent Technologies

    In the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the…

  • SampliQ Silica C18 Endcapped SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 25% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • HP-5ms

    Agilent Technologies

    Meets EN14331 Standards (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass spectral integrity Bonded and cross-linked…

  • DB-Wax

    Agilent Technologies

    Polyethylene glycol (PEG) Close equivalent to USP Phase G16 High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked Solvent rinsable …

  • DB-225

    Agilent Technologies

    (50%-Cyanopropylphenyl)-dimethylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Bonded and cross-linked Solvent rinsable Exact replacement of HP-225 Close equivalent to USP Phase G7 Similar Phases:…

  • Ultimate Unions

    Agilent Technologies

    Extend the life of your analytical GC or GC/MS column by using a guard column reliably connected to you analytical column with our high performance capillary GC column connector, the Ultimate Union. New-technology Ultimate Union kits eliminate the “arts and crafts” involved in…

  • Ultron Chiral Columns

    Agilent Technologies

    Direct racemic separations without derivatization Use Ultron ES-OVM to separate enantiomers of pharmaceuticals, such as hexobarbital, ibuprofen, and profenamine Ultron ES-Pepsin Chiral columns are best suited to separate basic compounds that are difficult to separate by other columns …

  • ZORBAX NH2 Columns

    Agilent Technologies

    Amino-propyl silane phase bonded to ZORBAX SIL Used for normal phase and weak anion-exchange, and reversed-phase  HPLC of polar compounds Vitamins A and D are separated in the normal-phase mode Carbohydrates and sugars are separated in the reversed-phase mode …

  • Prep LC Columns

    Agilent Technologies

    High loadability for maximum sample purification Easy scalability from 4.6 mm ID up to 50 mm ID for rapid method development High throughput 21.2 mm ID cartridges for fast purification Exceptional column stability and loadability up to pH 10 Agilent Prep LC columns are…

  • ZORBAX Rapid Resolution High Throughput 1.8 M Columns

    Agilent Technologies

    High pressure (600 bar) columns for ultra high speed or maximum resolution analyses with Rapid Resolution HT columns packed with totally porous, 1.8 µm packings Carefully engineered particles deliver maximum resolution at 25% less pressure than other sub 2-micron materials Reduce…

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • ZORBAX 80 Stablebond

    Agilent Technologies

    RR: Rapid Resolution 3.5 µm RRHT: Rapid Resolution HT 1.8 µm

  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • DB-XLB

    Agilent Technologies

    Exceptionally low bleed Low polarity Extended temperature limit of 340°/360°C Exhibits inertness to active compounds Suitable for confirmational analysis Excellent for pesticides, herbicides, PCBs and PAHs Useful for GC/MS MSD testing and certification…

  • ZORBAX Ion Exchange Columns - Sax And Scx

    Agilent Technologies

    ZORBAX SAX and 300SCX columns are based on rugged Zorbax silica Stable from pH 2-7 Provides high efficiency, rapid separations Compatible with organic mobile phase modifiers ZORBAX Bio-SCX Series II for 2-D separations Zorbax strong ion-exchange columns are available as both Strong Anion…

  • SampliQ Polymer SCX SPE Cartridges

    Agilent Technologies

    Ideal solid phase extraction for melamine analysis Ensures fast, reliable extraction of basic and cationic compounds Resistant to a wide variety of solvents Stable for pH ranges 0 - 14 Water-wettable Agilent's mixed-mode SampliQ SCX polymeric resin is a…

  • Deactivated Fused Silica Tubing

    Agilent Technologies

    Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation — the preferred choice for most applications due to its inertness and robustness.

  • Straight Ferrules

    Agilent Technologies

  • HP-FFAP

    Agilent Technologies

    Nitroterephthalic acid modified polyethylene glycol High polarity Temperature range from 40 to 250°C Designed for the analysis of volatile fatty acids and phenols Replaces OV-351 Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G35 …

  • Eclipse Plus C18

    Agilent Technologies

  • J&W DB-1ms Ultra Inert Capillary GC Columns

    Agilent Technologies

    DB-1ms is an excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns…

  • DB-Petro 100m, .25mm, 0.5um, 5"Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. 100% Dimethylpolysiloxane Configured for the analysis of petroleum process…

  • DB-225ms

    Agilent Technologies

    Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane Mid/high polarity Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) Low bleed Bonded and cross-linked Solvent rinsable Close equivalent to USP Phase G7 Similar Phases:…

  • HP-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limits: -60° to 325°C isothermally, -60° to 350°C programmed. -60° to 300°C isothermally, -60° to 320°C programmed for 0.53 mm columns -60° to 260°/280°C for =2.0 µm films Bonded and cross-linked Solvent…

Compare Tool

Select up to 3 products

Please Log In