Columns

Compare Tool

Select up to 3 products

1 - 32 of 242
Sort
View
Show

  • Amino Acid Standards

    Agilent Technologies

    *Consider shelf-life and buy limited quantities, 2714H95 ships as 1 g vials

  • Undeactivated Fused Silica Tubing

    Agilent Technologies

    Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical.

  • Eclipse Plus C18

    Agilent Technologies

  • Prep LC Columns

    Agilent Technologies

    High loadability for maximum sample purification Easy scalability from 4.6 mm ID up to 50 mm ID for rapid method development High throughput 21.2 mm ID cartridges for fast purification Exceptional column stability and loadability up to pH 10 Agilent Prep LC columns are…

  • Column GC Cap High Efficiency HP-5 20m, 0.18mm, 0.18um

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar Wide range of applications High temperature limit Bonded and cross-linked; solvent rinsable

  • Column Nuts

    Agilent Technologies

    Agilent MS interface column nuts (or transfer line nuts) are manufactured from a softer metal than the transfer line interface. This is to prevent stripping of the transfer line threads and costly repairs. Add a few MS interface column nuts to your next order and keep spares on hand.

  • Rapid Resolution and Rapid Resolution HT Cartridge Column System (400 bar)

    Agilent Technologies

    Economical and easy-to-use Offered individually and as a convenient three pack For fast, clean high throughput LC/MS, LC/MS/MS and combinatorial separations, we recommend the ZORBAX Rapid Resolution (3.5 µm) and Rapid Resolution HT (1.8 µm) Cartridge Columns. These cartridges…

  • SampliQ Carbon SPE Cartridges

    Agilent Technologies

    Generally used to retain polar analytes Solvent retention generally decreases as solvent becomes more polar A great option when more generally-used sorbents, such as C18, don’t perform specifically enough for your particular application SampliQ Carbon (graphitized) sorbents…

  • CP-Sil 5 CB Capillary Columns

    Agilent Technologies

    Agilent J&W CP-Sil 5 CB is a high efficiency column containing a 100% dimethylpolysiloxane phase. Separation is almost entirely based on boiling points, making this column suitable for a wide range of applications with a broad temperature range. Due to intensive cross-linking, CP-Sil 5 CB is…

  • Bonus-RP, 3.0X50mm, 1.8um, 600Bar

    Agilent Technologies

    This product is only available to U.S. Domestic Customers.

  • Filter System Replacement Parts

    Agilent Technologies

  • DB-502.2

    Agilent Technologies

    Available in 105 meters for volatiles analyses Excellent peak shape Bonded and cross-linked Solvent rinsable Similar Phases: Rtx-502.2, VOCOL, HP-VOC

  • Eclipse Plus Phenyl-Hexyl, 4.6X75mm, 3.5um

    Agilent Technologies

  • ZORBAX PrepHT Rx-SIL Columns

    Agilent Technologies

    Easy scale-up from analytical to preparative scale with ZORBAX phases Fast preparative separations, up to 2000 mg 5 to 7 µm particles for high efficiency and high yield Easy to install finger tight connections seal up to 5000 psi/350 bar High purity, high recovery and high…

  • ZORBAX Original Reversed Phase Columns

    Agilent Technologies

    Original ZORBAX columns are made with Type A silica and are useful for many applications of acidic or neutral compounds. These columns have a higher activity level and are therefore useful for separating isomers (e.g. cis-trans, geometric) or other compounds where silanol activity enhances…

  • DB-23

    Agilent Technologies

    50%-Cyanopropyl)-methylpolysiloxane High polarity Designed for separation of fatty acid methyl esters (FAMEs) Excellent resolution for cis- and trans-isomers Bonded and cross-linked Solvent rinsable Replaces HP-23 Close equivalent to USP Phase G5 Similar…

  • SampliQ Silica C18 ODS SPE Cartridges

    Agilent Technologies

    Reversed Phase (Non-Polar) 24% carbon loading Silica-based particles reduce pressure drop and increase flow reproducibility Average particle size of 45 µm and pore diameter of 60Å to reduce pressure drop and increase flow reproducibility Agilent’s trifunctional…

  • ZORBAX Eclipse XDB Columns

    Agilent Technologies

    Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB…

  • DB-5ms

    Agilent Technologies

    Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane Non-polar Very low bleed, suitable for GC/MS Exhibits inertness to active compounds Temperature limits are -60° to 325°/350°C Improved signal-to-noise ration for increased sensitivity and mass…

  • Superspher Reversed-Phase Columns

    Agilent Technologies

    Superspher is a high performance 4 µm silica support. It offers excellent pressure/performance ratio for analysis of complex mixtures requiring high peak capacity. Superspher columns are available as two C18 phases; one endcapped for best peak and one non-endcapped for alternate…

  • DB-1301 And DB-1701

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. DB-1301: (6%-Cyanopropyl-phenyl) methylpolysiloxane DB-1301: Equivalent to USP…

  • ZORBAX Rapid Resolution 3.5 m Eclipse Columns

    Agilent Technologies

    Reduce analysis time and solvent usage and increase sample throughput High efficiency in short and ultra-short column lengths Available in analytical (4.6 mm) and narrow-bore (2.1 mm) ID Comparable lifetime to 5 µm columns Agilent ZORBAX Rapid Resolution columns, with a 3.5 µm particle size,…

  • DB-624

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Specifically designed for the analysis of volatile priority pollutants No…

  • DB-ALC1 And DB-ALC2

    Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked …

  • Eclipse Plus Phenyl-Hexyl, 4.6X150mm, 3.5U

    Agilent Technologies

    This product is only available to U.S. Domestic Customers.

  • GC GS-Q-30m-Megabore, .53m, 5" Cage

    Agilent Technologies

    GC capillary columns are typically wound on 7 inch cages that fit into standard-sized GCs like the 6890. The 6850 GC has a smaller oven which requires the use of columns wound on a smaller cage diameter. Porous divinylbenzene homopolymer A PLOT column with polarity between Porapak-Q…

  • Carbowax 20m And HP-20m

    Agilent Technologies

    Polyethylene glycol, MW 20,000 Equivalent to USP Phase G16 Similar Phases: DB-WAX, HP-INNOWax, DB-WAXetr Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M.

  • DB-5

    Agilent Technologies

    (5%-Phenyl)-methylpolysiloxane Non-polar General purpose column Wide range of applications Low bleed High temperature limit: -60° to 325/350°C* Bonded and cross-linked Solvent rinsable Wide range of column dimensions available Equivalent to USP…

  • ZORBAX Carbohydrate Analysis Columns

    Agilent Technologies

    Reproducible - each lot of this application specific aminopropyl column packing material is use-tested for specific monosaccharide and disaccharide separations Efficient - uses ZORBAX porous silica microsphere technology. Silica manufacturing, bonding and packing are all performed in Agilent's…

  • Column GC Cap High Efficiency DB-WAX 40m, 0.18mm, 0.18um

    Agilent Technologies

    Polyethylene glycol (PEG) High polarity Lower temperature limit of 20°C is lowest of any bonded PEG phase; improves resolution of low boiling point analytes Column-to-column repeatability Bonded and cross-linked; solvent rinsable

  • DB-5.625

    Agilent Technologies

    Equivalent to a (5%-Phenyl)-methylpolysiloxan Non-polar Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* Surpasses EPA performance criteria for semivolatiles Inert for base, neutral and acidic compounds High…

  • DB-Tph 30m, 0.32mm, 0.25um

    Agilent Technologies

    Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT Three analyses in one injection: gas range organics, diesel range organics and motor oil Fast run time Bonded and cross-linked Solvent rinsable

Compare Tool

Select up to 3 products

Please Log In