Compare Tool

Select up to 3 products

All Products

Spectrophotometer Cells/Cuvettes

1 - 32 of 184
Sort
View
Show
  • Thomas Square Spectrophotometer Cells

    Thomas®

    Square, 10 mm Light Path Cells Outside dimensions approximately 12.5 x 12.5 x 46 mm high Light path: 10 mm, ±0.01mm Teflon® cover included Matched sets are supplied in cushioned storage box Cell bodies are of fused-wall construction Cells are usable in spectral…

  • Acrylic and Polystyrene Spectrophotometry Cuvettes

    BrandTech®

    BRAND plastic cuvettes are an excellent choice for most spectrophotometry applications in the visible range. Manufactured from polystyrene (PS), they provide accurate, reliable results, even at wavelengths as low as 300nm. BRAND plastic cuvettes are compatible with most spectrophotometers and…

  • Thomas Polystyrene Cuvettes

    Thomas®

    Disposable Polystyrene Cuvettes Convenient and affordable Save time with no cleaning required Prevent cross-contamination Useable in the range of 340 to 750 nm Tight dimensional tolerances ensure high reproducibility from package to package. 10 mm path length; 12.5 x 12.5…

  • Sample Cuvette, TDx, Glass

    Evergreen Scientific

    Sample Cuvette for Abbott TDx™, 12 x 50mm, borosilicate glass, natural color

  • Sample Cells for Hach Spectrophotometers

    Hach

    Comes as a set of matched pair cells.

  • UV Plate 96 Well, Flat Bottom, Cs 50

    Corning

    Certified DNase and RNase free UV transparent bottom is molded, not adhered, to an acrylic top for maximum leak resistance Ideal for UV absorbance readings with low background, especially at 260 and 280 nm Flat bottom wells have volume of 370 µL UV-Plate has a special…

  • Semi-Micro Cells

    Agilent Technologies

    Semi-micro and micro cells have an inner width of 4 mm to 2 mm. The thickness of the base is 9 mm. All semi-micro and micro cells are for use with spectrophotometers having a beam height of 15 mm. For applications with a wave length range of interest in the visible range use our low cost Agilent…

  • Sample Cell, 1” Round Glass, 10 mL

    Hach

    Comes as a set of 6 with caps

  • Standard Rectangular Quartz Cells

    Starna Cells

    Spectrosil® Far UV Quartz windows, Useable range: 170 to 2700 nm Standard rectangular cells or Macro cells, Type 1, are the most common cells used in analytical chemistry. The exterior dimensions allow the cells to be used with virtually every spectrophotometer and photometer instrument…

  • Thomas Rectangular Spectrophotometer Cells

    Thomas®

    Minimum working capacity as shown in listings Cell bodies are of fused-wall construction. Matched sets are supplied in cushioned storage box. Includes Teflon® cover. 8491M18 cells require 8494J20 adapter to accommodate cells in standard cell carrier.

  • Thomas Polystyrene Fluorometry Cuvettes

    Thomas®

    Disposable Polystyrene Cuvettes for Spectrofluorometers Negligible variation in absorbance between the 4 optical sides allows readings from any side. Standard 10 mm light path Designed specifically for fluorometry, cells are also ideal for nephelometry and spectrophotometry. The…

  • Thomas Methacrylate Cuvettes

    Thomas®

    Disposable Methacrylate Cuvettes Convenient and affordable Save time with no cleaning required Prevents cross-contamination Useable in the range of 285 to 750 nm. Tight dimensional tolerances ensure high reproducibility from package to package. 10 mm path length; 12.5 x 12.5 x 45 mm outside…

  • UV-Cuvettes, Ultra-Micro

    Dynalon

    UV-transparent disposable cuvettes replace expensive, fragile quartz cuvettes and are excellent for DNA,  RNA, and protein analysis between 220-900nm. Resistant to many aggressive solvents, they eliminate the tedious maintenance, cleaning, and contamination of quartz  cuvettes. Packaged…

  • Thomas Cylindrical Spectrophotometer Cells

    Thomas®

    Cylindrical Cells End windows fused to cylindrical body, of far UV silica, range 170 to 2,600 nm With Teflon stopper; 10 mm and 20 mm have single neck, longer sizes have 2 necks Light path length and minimum sample volume given in listings

  • Dual Path Cell, Spectrosil

    Starna Cells

    Spectrosil® Far UV Quartz windows, Useable range: 170 to 2700 nm Dual path length cells Types 52 and 53 allow for both fluorescence and absorbance measurements to be made with small volumes with a choice of two path lengths, dependent on the orientation of the cell in the cell holder. All…

  • Cuvettes, 10mm Sq Glass (Set2) *L

    Thermo Scientific UV-Vis

    For use with Thermo Scientific Spectronic 20+ and 20D+ Spectrophotometers. Set of 2 Square Cuvets Lightpath: 10mm L [METRIC]: 10mm

  • Sample Cell: 1 Square Glass

    Hach

    Sample Cell: 1 Square Glass 10mL & 25mL for DR/4000.

  • Cuvette Holder, Pk. 5

    Thomas®

    Holds 12 glass, silica or plastic disposable cuvettes (external dimensions 12.5 x 12.5 mm) Permits easy viewing of solution color to be measured Helps prevent breakage Dimensions: Approximately 6 3/4 x 2 x 1/2”H

  • Cuvettes for Spectrophotometry

    Jenway (Bibby Scientific US)

    Jenway offer an extensive range of cuvettes for measuring liquid samples. The cuvette required will depend on the wavelength range required and the sample volume available. Glass cuvettes are only suitable for the visible region, whereas quartz may be used in both the UV and visible region. A 10mm…

  • Chloroform EMPLURA®

    EMD Millipore

    CAS Number: 67-66-3 UN Number: UN1888 Solubility: 8 g/l (20°C) Melting Point: -63°C Molar Mass: 119.38 g/mol Boiling Point: 61°C (1013 hPa) Vapor Pressure: 211 hPa (20°C) Refractive Index: 1.45 Density: 1.48 g/cm3 (20°C)

  • Standard Rectangular Spectrophotometer Cells w/Lid

    Varsal

    A wide selection of cells to meet the demanding specifications of UV/VIS spectrophotometers. All cells are fire-fused so they can be cleaned repeatedly and there are no seams or joints to lock in air. 100% handcrafted and individual inspection guarantees the highest quality levels and excellent performance.

  • Thomas Sub-Micro Cells

    Thomas®

    Designed for the measurement of very small samples Retain exterior dimensions of standard cells Volume range: 10 µL to 160 µL Path length: 10 mm The entrance to the sample compartment is hemispherical to eliminate sharp corners which can cause sample loss due to…

  • Specac® Omni Cell demountable cell for IR spectroscopy

    Sigma-Aldrich

    General description Specac′s demountable Omni Cell System presents a novel approach for the analysis of liquid, mulls, pastes, and cast film samples in UV, Vis, NIR, and IR transmission spectroscopy, with one cell mount being suitable for all applications. This transmission…

  • Sample Cell: 1 Round Plastic 10mL with 1cm Pathlength

    Hach

    Sample cell, 1" round plastic. Comes as a set of 2 with screw caps Used with DR/800 series colorimeter and select pocket colorimeter instruments 1 cm pathlength 10mL

  • Macro Cells

    Agilent Technologies

    The macro cell which is defined by DIN 58963 as a rectangular cell with an inner width greater than 5 mm has emerged as the standard for photometry. The most widely used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm (height x width). The length of the cell is dependent on…

  • Thomas Methacrylate Fluorometry Cuvettes

    Thomas®

    Disposable Methacrylate Cuvettes for Spectrofluorometers Negligible variation in absorbance between the 4 optical sides allows readings from any side Standard 10 mm Light Path Designed specifically for fluorometry, cells are also ideal for nephelometry and spectrophotometry. The methacrylate…

  • NMR Sample Tubes

    Ampol

    10 mm diameter with 0.60 mm wall thickness ASTM type I Borosilicate glass Concentricity and camber tolerances are strictly maintained for superior performance. Shimming that may have been required with other manufacturers' tubes may no longer be necessary. All tubes are supplied with end…

  • NMR Tubes, Disposable Grade, 5 mm, N-51A Borosilicate Glass, Caps Unattached

    Kimble

    Approx. Frequency: 100 MHz 0.015 Wall Thickness 7 or 8 inch lengths Disposable grade NMR tubes. Each tube is supplied without sandblasted marking spot in a bundled multi-pack. Caps included but not attached.

  • Sample Cell: 1 Square Glass 10 mL matched set of 8

    Hach

    Comes as a matched set of 8 cells. Use in Combination with Hach Spectrophotometers

  • 5 mm Diameter NMR Tubes

    Corning

    Precision 5 mm diameter NMR tubes are made from quality Pyrex® borosilicate glass for compatibility with ground joints, valves, and vacuum racks. Made using precision bore tubing manufacturing techniques proven most reliable in NMR applications. A complete selection of tubes for all types of…

  • Fluorimeter cuvettes Polymethacrylate, without stopper

    Sigma-Aldrich

    Synonym: cuvette, plastic cuvette, plastic cuvettes Compatibility Not compatible with some organic solvents or strong acids. General Description These cuvettes have four optically clear sides. Note: polystyrene and polymethacrylate cuvettes are incompatible with some organic…

  • Photometric Accuracy and Stray Light Calibration Wavelength Kit

    Cole-Parmer

    Verify the performance and accuracy of your spectrophotometer right in your own lab. These permanent standards do not have to be recalibrated due to material aging. Unique material construction is scratch resistant and provides stable optical performance. Photometric Accuracy and Stray Light…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.