    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Reduces water to less than 10 ppb; indicator changes from yellowish-green to blue at 5% relative humidity Prepurged for fast stabilization Reduces noise from high-sensitivity detectors Heavy-walled glass body prevents oxygen and water infusion 10 µm frit prevents microparticulate…

  • Agilent Technologies

    …Electrolytic Conductivity Detectors Molecular Sieve 13X and a band of Indicating Molecular Sieve 4Å Available in 70 cc, 100 cc and 250 cc sizes Heavy wall borosilicate glass tube — no moisture diffusion Refillable The 100 cc unit will treat 10 standard…

  • Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from Lexan brand polycarbonate tubing. Lightweight, chemically resistant and of superior strength when compared to traps

  • The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide (blue) in the moisture indicator. Available as a kit with the necessary 1/8" brass connectors, and…

  • In-line moisture trap. Drierite indicating agent and MolecularSieve 5A are packed in glass which is enclosed in a safety plastic tube in the event the glass breaks. Unique loading design allows operation in any orientation without channeling. For use with pressures up to 100 psig. Designed for use…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • Agilent Technologies

    …GC gas purifiers are available in different sizes and configurations such as combination gas traps that remove moisture, oxygen, and/or organics with a single trap. Using oxygen and moisture traps for carrier gas extends column life and protects the instrument. Removing hydrocarbons helps improve…

  • …that surrounds the glass indicator section of the filter is sealed, so the gas flow is secure even if the glass is broken. Removes Moisture The Moisture trap removes water from inert gases, air or hydrogen to less than 20 ppb at flow rates up to 2 L/min. The trap has a capacity for water…

  • MilliporeSigma

    …valves.The indicating 4A changes from blue to tan at 20% relative humidity.Note: Not for use with carrier gas streams.Dimensions: •400 cc Traps: 17 1/2 in. (44.4 cm) long x 2 in. (51 mm) diameter Synonyms: ECONOMY MOISTURE-REMOVING TRAP, 400CC, 1/4IN FITTINGS Application: Moisture trap may…

  • …in one trap and is packed and purged under helium. The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide(blue) in the moisture indicator. Available…

  • The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide (blue) in the moisture indicator. Available as a kit with the necessary 1/8" brass connectors, and…

  • …connectors are equipped with stainless steel frits to prevent particulates from entering the gas stream. Indicating 4Å is the preferred adsorbent for GC gas drying. Blue indicating sieve turns buff at 20% relative humidity. Agilent Technologies products are intended for sale/shipment…

  • …Without the appropriate gas purifier, problems such as noisy baselines, moisture entering GC column, excessive bleed, reduced column lifetime and irreproducible results will occur. These problems are created by hydrocarbons, moisture and oxygen in the carrier gases. Advanced Gas Filter System …

  • PerkinElmer

    Gas contacts only glass, metal and the adsorbents for purity. The Drierite ® indicator and molecular sieve 5A are packed in glass protected by an outer plastic tube in the event that the glass breaks. Unique loading design allows operation in any orientation without channeling. Designed for GC…

  • …Ultra-Low Cold Trap reaches -85°C in less than 30 minutes. Ready indicator illuminates when the collector coil reaches operating temperature of -40°C. Clear canister is attached to the left side of the cold trap and can hold various trap inserts. These trap inserts remove acids, moisture,

  • Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • …with two fluoro-elastomer seals. The polycarbonate shield that surrounds the glass indicator section of the filter is sealed, so the gas flow is secure even if the glass is broken. Removes Organics The Hydrocarbon trap removes C5 weight and heavier hydrocarbons from inert gases, air or hydrogen to…

  • Agilent Technologies

    …deep brown as saturation occurs. The Indicating Oxygen Trap (IOT) is designed for use in conjunction with high capacity, non-indicating oxygen traps. When properly installed downstream from the non-indicating trap, the IOT provides a visual indication of oxygen breakthrough before contamination…

  • Install an indicator after the Click-On in-line gas filter so there is no confusion about when to replace the traps. Oxygen: green to grey Moisture: beige to clear Note: Fittings sold separately.

  • …an indicating trap, your gas purification issues are handled in one central location. Removes moisture, hydrocarbons, and oxygen from carrier gas, extending column lifetime Produces high-purity carrier gas for most applications Includes one each: moisture, hydrocarbon, and indicating

  • …with the specified gas to shorten downtime Please Note: We recommend using an indicating oxygen trap (e.g., cat.# 22010) downstream from a VICI Mat/Sen purifier to continually ensure gas purity and indicate absolute change-out time. *Warning: Do not use with nitrogen containing more than…

  • …longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process. Carrier Gas Purity Carrier gas should contain less than 1ppm of oxygen, moisture, or other trace contaminants, to prevent column degradation, increase…

  • …longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process. Carrier Gas Purity Carrier gas should contain less than 1ppm of oxygen, moisture, or other trace contaminants, to prevent column degradation,…

  • moisture, oils, dust, hydrocarbons, oxygen, sulfur compounds and more. Select the proper filter for your application needs. Advanced Filter System- N9303963 Replacement cartridge- N9303964 Manifold and Mounting Hardware- N9306139 New Advanced Filter System Two indicators, for oxygen and moisture.