Flat bottom, Non-Sterile
-
Treated or non-treated surface models Black or clear versions Can be used for both top and bottom reading instruments 96 Half-Area Well microplates are available in a range of configurations. Bottoms are 60% thinner than conventional polystyrene plates resulting in lower background fluorescence…
-
Black, flat bottom Nonbinding surface 360 µL well volume Bottoms are 60% thinner than conventional polystyrene plates, resulting in lower background fluorescent and enabling readings down to 340 nm. Microplates are designed to reduce well-to-well crosstalk during…
-
Fluorescent and luminescent assays Raised well bottoms for higher sensitivity Flood reservoirs reduce contamination Corning® 1536 well microplates are the highest density microplates available for high throughput screening while conforming to standard microplate footprint and…
-
Immobilizer™ Streptavidin Plates and Modules
Thermo Scientific NuncRapid coupling of biotinylated bio-molecules Streptavidin is covalently bound to the surface Ready to use Excellent binding capacity Minimal leaching of coupled biomolecules from the surface Binding site easily accessible Low non-specific binding High signal to…
-
-
Stacked plates can be easily separated Working volume up to 1.5 µL Extra wells can be used as controls Treated or untreated versions available Low volume microplates are primarily suited for the immobilization of large molecules, such as antibodies, that have large…
-
96 Well Half-Area Assay Plates
CorningSaves reagents Fits standard readers Polystyrene Unique half-area plates achieve assay miniaturization without using 384 well plates. Half-area plates can help save on rare and expensive reagents by reducing the amount of reagent needed per well, while still retaining the ability…
-
96 Fluoronunc Modules and Plates
Thermo Scientific NuncFor fluorescence-based immuno assays and ELISA technologies Minimum cross-talk Maxisorp™ and PolySorp® surfaces available Alphanumeric well identification Available in white, black or clear Modules have 1 x 8, 1 x 12 or 2 x 8 strips in a 96 well…
-
Nunc 96 Well Optical Bottom Plates
Thermo Scientific NuncNon-treated plates are optimized for scintillation counting White or black upper structure with polymer bottom plates combine the clarity of virgin crystalline polystyrene with optimal surface for a wide range of HTS applications Working volume range: 50 - 200 µl/well
-
Certified DNase and RNase free UV transparent bottom is molded, not adhered, to an acrylic top for maximum leak resistance Ideal for UV absorbance readings with low background, especially at 260 and 280 nm Flat bottom wells have volume of 370 µL UV-Plate has a special…
-
384 And 1536 Well Assay Plates
CorningFor high throughput screening Solid polystyrene Automation-friendly 96-well footprint Reduces total working volume up to 90% Compatible with all leading 384 well readers and detectors Comes with either a tissue-culture-treated surface for cell-based assays or a non-treated surface for…
-
384 Well Plates
Thermo Scientific NuncFour times more wells in the same footprint as 96 well plates MaxiSorp™ surface Available in white, clear or black Total volume per well: 120 µL 384 well plates allow miniaturization of assays and are compatible with robotics, automated readers and liquid handling systems. Plates are…
-
UV Transparent Microplates
Corning96-well, half-area 384-well, full-area Flat bottom Both the 96- and 384-well UV microplates have a UV-transparent well bottom and are well suited for determining protein and/or nucleic acid concentrations. Microplates are certified for low background and consistent performance at 260…
-
Raised well rims Comes with high binding, TC-treated or non-treated surface Built to proposed industry standard footprint These solid black and white, opaque polystyrene plates are tested on a lot-to-lot basis for capacity and low fluorescent/ luminescent background. Plates have…
-
1536 Well Black with Clear Flat Bottom Polystyrene NBS Microplate Compatible with standard readers and automation Compatible for bar coding Superior performance compared to competitor plates: Lower CVs, higher signal-to-noise ratios, and lower background fluorescence NBS surface can reduce…
-
96 Well Half-Area Assay Plates
CorningSaves reagents Fits standard readers Polystyrene Unique half-area plates achieve assay miniaturization without using 384 well plates. Half-area plates can help save on rare and expensive reagents by reducing the amount of reagent needed per well, while still retaining the ability to be read in…
-
Immobilizer™ Streptavidin Plates and Modules
Thermo Scientific NuncRapid coupling of biotinylated bio-molecules Streptavidin is covalently bound to the surface Ready to use Excellent binding capacity Minimal leaching of coupled biomolecules from the surface Binding site easily accessible Low non-specific binding High signal to…
-
Reduces protein and nucleic acid binding Minimizes molecular interactions Reduces anti-fluorescence Treated or untreated versions The Corning® low flange 384 well black clear bottom microplates are available in both standard tissue culture treated surface for cell based assays and NBS™…
-
96 Well EIA/RIA Assay Plates
CorningCertified surface chemistry Ultra-low coefficient of variation (CV) for uniform binding Designed for research and in vitro diagnostic assays, all EIA/RIA plates and strips are manufactured from a special medical grade polystyrene for uniform binding, high optical clarity and low background…
-
Immuno™ Clear Standard Modules
Thermo Scientific NuncPerform applications which are delivering well-to-well reproducibility with Thermo Scientific™ Immuno Clear Standard Modules, which feature Nunc™ module plates developed for ELISA techniques. Manufactured to fit standard equipment, modules provide flexible use of components with small…
-
Opaque walls to prevent well-to-well cross talk Optical bottoms for direct microscopic viewing Plates can be used in both top and bottom reading instruments Built to proposed industry-standard footprint The bottoms of these 96 well clear-bottom plates are 60% thinner than…
-
Assay Plate, MaxiSorp, Flat Bottom, 96 x 0.4 mL, w / Certificate and Barcode /…
Thermo Scientific Nunc -
Superior performance compared to competitor plates: Lower CVs, higher signal-to-noise ratios, and Lower background fluorescence Processed for superior flatness with minimal variability within plate and between plates Non-sterile Without lid
-
Conical flat bottoms 1 Protein well 1 Reservoir The 96 wellCOC Protein Crystallization Microplate features 1:1, 4 µL conical flat bottom wells treated for hydrophilicity. Each well contains one 4 µL conical flat bottom protein well and one 100 µL reagent…
-
F96 MicroWell™ Plates
Thermo Scientific NuncMaxiSorp™ and PolySorp™ surfaces for solid phase immuno assays Non-treated surfaces for screening assays Working volume range: 50 - 250 µl/well
-
96 Well Half-Area Microplates
CorningBlack or white flat bottoms Reduced well-to-well crosstalk Non-sterile Microplates have half the growth area of standard 96 well microplates. Model 6928C15 (white bottom) enhances luminescent signals and has low background luminescence and fluorescence. It is designed to reduce well-to-well…
-
Designed for sitting drop crystallization Meets 96 well microplate standards for automation Low water absorption of polymer prevents loss of protein drop volume Microplate is manufactured from an advanced polymer with high resistance to commonly used solvents, including acetone,…
-
Module Plate Immobilizer Amino F8X12 Clear NS PS
Thermo Scientific NuncRapid covalent coupling of peptides, nucleotides, proteins, enzymes and antibodies Ready to use - no activation or blocking steps Low reagent consumption High signal to noise ratio Long term stability at room temperature Surface optimized to minimize steric hindrance and…
-
Black with clear flat bottom Working volume 5-40 µL Round well design reduces wicking Non-binding (NBS) surface is a Corning proprietary treatment technology used on polystyrene microplates to create a non-ionic hydrophilic surface (polyethylene oxide-like) that minimizes molecular…
-
White wall plates are designed to reduce well-to-well crosstalk during luminescent assays Recommended working volume of up to 20 to 80uL Enhanced flatness provides low intra- and inter- plate CV’s Nonbinding (NBS) surface is a Corning proprietary treatment technology used on…
-
Designed to reduce well-to-well crosstalk during luminescent assays Recommended working volume of up to 20 to 80µL Conforms to standard microplate footprint and dimensions High binding surface binds medium (>10kD) and large biomolecules that possess ionic groups and/or hydrophobic…
-
96 Well Storage Plates
CorningAutomation friendly Solvent resistant Certified RNase/DNase- free These 96 well polypropylene plates are built to the industry standard footprint. They are available in flat, round and V-bottom formats to meet a wide variety of assay and storage needs. V-bottom holds 320 µL. Flat and round…