  • The Insta-Test Low Range Hydrogen Peroxide Test Strips is a convenient way to quickly measure peroxide levels in water with fast dip and read results. Range and sensitivity is 0, 1, 3, 10, 30, 50 ppm.   Applications: Drinking Water, Industrial Water Boiling and Cooling, Laundry…

  • All the benefits of DPD tablets in a liquid Can be used with existing LaMotte chlorine comparators or colorimeters Lower cost per test than tablets Quicker results and clearer colors than tablets DPD 1A and 1B reagents are added to a 5 or 10 mL sample to test free chlorine.…

  • Contents: 30 mL Hydrogen Peroxide 3% 30 mL Chloride Reagent A 30 mL Sulfuric Acid, 0.5N 15 mL Phenolphthaein Indicator 0.5% 2 x 30 mL Silver Nitrate 0.171 N 1 Sample Tube, 5-10-25 mL w/ cap  

  • Direct Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL   All-purpose…

  • Tests 0-5 ppm Five intervals: 0, 0.5, 1, 3 and 5 50 strips per vial Unique range and sensitivity covers critical chlorine concentrations for many applications of food processing, water/wastewater treatment, education and other areas.

  • This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • Applications: Drinking Water, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater 2951HR High Range QAC test papers are specifically formulated to read high range levels of QAC. Range and sensitivity is 200, 400, 600, 1000, 1500 ppm.

  • The LaMotte phosphate reagent refill is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is easy to handle and convenient to use.

  • Applications: Industrial Water Boiling and Cooling, Water and Wastewater This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.

  • 3 ranges of PAA test strips available covering low (0-50 ppm), medium (0-160 ppm) and high (0- 1,000 ppm) range concentrations The Insta-Test® 3000 test strips determine peracetic acid concentrations from 0-160 ppm. The test has a 10 second development time. The container has a desiccant liner…

  • Popular AR-02 outfit provides tests for Hardness, Iron, and pH. Drop count tests for Hardness (10 ppm or 1 gpg/drop) Octa-Slide tests for Iron (0.5-10 ppm) and pH (5.0-10) Includes 100 tests for Iron and 50 tests for each pH and Hardness

  • Replacement cyanuric acid test strip tablets. Used for Cyanuric Acid instrument grade test with Lamotte Kits.

  • Low Range, 0-2500 ppb. 25 test strips.

  • Replacement LaMotte ColorQ Alkalinity Indicator reagent. This replacement reagent has a bottle size of 2 oz. This Reagent is for use with the Lamotte ColorQ Pro 7 Plus Test Kits.

  • No color matching, no look up charts, no guessing! The unique, multi-test ColorQ pool and spa hand-held photometer reads SEVEN test factors (Free Chlorine, Total Chlorine, Bromine, pH, Alkalinity, Calcium Hardness, and Cyanuric Acid) directly on a digital display. Featuring an innovative…

  • LaMotte

    Octet Comparator For determining silica in natural and industrial waters Employs modified APHA Method 425D Octet Comparator has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0 and 10.0 ppm silica Sufficient for 50 tests

  • For determining salinity (as chloride content) of water Employs modified APHA Argentometric method Range of 0 to 20 ppt salinity in 0.4 ppt increments Sufficient for 50 tests at 20 ppt 

  • 3119 Octet Comparator Method Color standards for 0.2, 0.4, 0.6 and 1.0 ppm NO3—N Color standards for 0.2, 0.4, 0.6 and 1.0 ppm PO4 Sufficient for 40-50 tests 

  • The Iodine test papers are a convenient way to test Iodine in water with fast results. Range and sensitivity is 0, 30, 60, 120, 180 ppm.

  • The hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence.

  • Applications: Food and Beverage, Environmental Education, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater This kit tests for nitrate or nitrite using the Octa-Slide 2 Comparator. Range/sensitivity is 0.25, 0.5, 1.0, 2.0, 4.0, 6.0, 8.0, 10.0 ppm…

  • Yes/No qualitative test Sensitivity less than 2.2 per 100 mL of sample No incubation equipment required; only room temperature

  • This kit tests for Sodium Nitrite using the Direct Reading Titrator method. Applications: Industrial Water Boiling and Cooling, Water and Wastewater Range/sensitivity is 0-1000 ppm/20 ppm NaNO2

  • The LaMotte Stormwater MS4 Kit has instrumentation and reagent systems to provide a preliminary screening of stormwater outflow, and to determine whether it is contributing to the overall pollutant load from precipitation events. Meets guidance as set forth by USEPA. Features …

  • DPD Tablet Octa-Slide (9859G42) Sufficient for 50 tests Employs DPD tablet method: EPA- accepted method for NPDWR Octa-Slide has color standards representing 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 and 3.0 ppm Cl Low Range Octet Comparator (9859H10) Employs DPD tablet…

  • Formula: Mixture

  • Direct Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter…

  • For Environmental Studies For determining life-supporting chemistry of fresh-water environments, including ponds, lakes, streams, rivers and marshes Tests for: carbon dioxide, D.O., hardness, nitrate, trace phosphates, wide-range pH and silica Includes water sampling bottles, report forms and…

  • 4507 Drop Count Method For determining anionic forms of detergent One drop equals 1.0 ppm detergents; range approximately 0 to 5.0 ppm Sufficient for 60 tests at 5.0 ppm

  • Octet Comparator For determining trace levels of free cyanide in water Octet comparator has color standards representing 0.00, 0.10, 0.15, 0.20, 0.25, 0.30, 0.35 and 0.40 ppm Free CN - Sufficient for 50 tests  

  • Direct Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…

  • This LaMotte Phosphate test kit tests for low range Phosphate using the LRC Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43-. Applications: Environmental Education