Cannon Instrument

Compare Tool

Select up to 3 products

HomeAll Products

Cannon Instrument

33 - 63 of 63
Sort
View
Show
  • CANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…

  • quick-ship

    Cannon Instrument

    Contains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.

  • For preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…

  • For glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F…

  • Calibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…

  • Cannon Instrument

    Tapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.

  • Cannon Instrument

    Includes permanently attached round metal holder, for hole 51 mm (2 in) in diameter.

  • For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…

  • Cannon Instrument

    With three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…

  • Cannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…

  • CANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).

  • CT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…

  • Quick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…

  • Based on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…

  • Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…

  • Cannon Instrument

    Programs are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…

  • The Dostmann P795 dual channel digital thermometer is a precision hand held device for accurate temperature measurement. Dual channel technology allows simultaneous display of two readings or a differential result to meet the needs of automated viscosity applications, such as side-by-side kinematic…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…

  • Cannon Instrument

    All Cannon viscometer holders fit holes 51 mm (2 inches) in diameter. Rubber holders are made of neoprene rubber. Plastic holders are self-aligning and hold the viscometer firmly by means of a spring clip. Metal holders are also self aligning, and are constructed of chrome-plated machined brass.…

  • Similar to Cannon-Manning Vacuum (CMV, 9724-H50) series, but with graduated capillary instead of two timing bulbs. Provided with certificate of calibration and instruction sheet. Viscosity range, poise: 2400 - 52000 Approx. constant poise/second at 300mm Hg Bulb B: 128 Approx.…

  • The Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…

  • The Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…

  • The Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…

  • The Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…

  • Cannon Instrument

    The Cannon Instrument power pack is an ideal to have in any chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories.

  • Cannon Instrument

    For CANNON Mini-Rotary Viscometer (CMRV) (see ASTM D 3829 and ASTM D 4684) Exhibits yield stress of 70 Pa ±35 Pa at –30°C

  • Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of…

  • Cannon Instrument

    For CANNON Mini-Rotary Viscometer (CMRV) (see ASTM D 3829 and ASTM D 4684) Exhibits yield stress of 70 Pa ±35 Pa at –35°C

  • Sturdy two-drawer unit fits beneath the Constant Temperature Bath Provides elevated viewing of the bath and ample room for storage of viscometers and other accessories. Overall dimensions: 457 mm wide x 457 mm deep x 165 mm high. Weight: 24 lbs.

  • The Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…

Compare Tool

Select up to 3 products