Weathered Diesel Fuel #2 Kit
RestekCompound List 31233: Diesel Fuel #2 (ASTM Class 5 Accelerant) Diesel fuel #2: unweathered (68334-30-5) 31234: Diesel Fuel #2 (ASTM Class 5 Accelerant) Diesel fuel #2: 25% weathered (68334-30-5) 31235: Diesel Fuel #2 (ASTM Class 5 Accelerant) Diesel fuel #2: 50% weathered (68334-30-5) …
-
Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS. Formulated and grouped for maximum long-term stability* and well-balanced chromatographic performance. Quantitatively tested to confirm…
-
Compound List (C10) n-Decane (124-18-5), 20 µL/L (C40) n-Tetracontane (4181-95-7), 20 mg/L
-
Replace active hydrogen, reducing polarity and making the compounds more volatile. Increase stability of derivatives.
-
proprietary Crossbond phase These columns separate to baseline all blood alcohol compounds in blood, breath, or urine, in less than 3 minutes, under isothermal conditions. Isothermal analysis increases productivity by eliminating the need for oven cycling. Confirmation is easily achieved with…
-
-
Mininert valves are very convenient for repetitive sampling and limit content exposure to the silicon septum. Models are available for screw-cap and crimp-top vials. The crimp-top valve for 20 mm ID glassware slides into the neck of the vial. Turn the threaded flange to secure a tight fit.
-
Topaz GC inlet liners feature revolutionary technology and inertness to deliver you the next level of True Blue Performance: Deactivation —unbelievably low breakdown for accurate and precise low-level GC analyses Reproducibility —unbeatable manufacturing controls and QC…
-
Securely holds up to 36 headspace vials (fits 6, 10, or 20 mL vials). Vials lock in rack for convenient one-handed cap removal. Openings in the bottom of each well facilitate drainage. Alphanumeric indexing on rack simplifies sample identification. Easy to clean and fully autoclavable.*…
-
Use 1/8" and 3/16" OD columns in 1/4" on-column injection ports. Centers column perfectly in injection port to eliminate bent syringe needles. Slotted design prevents carrier gas occlusion. Vespel/graphite reducing ferrules make installation easy. Includes all nuts &…
-
1,2-Dibromo-3-chloropropane (96-12-8) 1,2-Dibromoethane (EDB) (106-93-4) 1,2,3-Trichloropropane (96-18-4)
-
PEEK Tubing Elbows
RestekTubing elbows (90° and 180°) are ideal for routing 1/16" PEEK tubing through your system. Simply snap the tubing into the elbow. Prevent pinching of PEEK tubing, which can cause high pressure.
-
Parker Nuts
RestekPlease note: Nuts and ferrules are not treated unless requested (custom parts). Nuts and ferrules normally are not in contact with sample pathway, and thus do not require coating.
-
Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or “core-shell” particles) with the resolution of highly selective USLC technology. This new breed of chromatographic column allows you to more easily achieve peak separation and…
-
-
Tapered for high recovery of contents Work with Mininert sampling valves
-
Features two common alkyl halides—chloromethane and chloroethane—that can form during drug synthesis. High-concentration (5,000 μg/mL) solution maximizes flexibility; ideal for analyzing pharmaceutical genotoxic impurities (GTIs). Quantitatively tested to confirm composition…
-
2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane By adding β or γ cyclodextrin to our bonded Rtx-1701 stationary phase, we greatly enhance overall utility and column lifetime for our chiral columns, compared to…
-
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels! Ideal for food and flavor analysis (e.g., essential oils), fragrance…
-
The model 1062 vacuum bag sampler provides fast sampling with zero cross-contamination. A vacuum created in the box draws air into the sampling bag without drawing it through the vacuum pump first, as is the case with standard air sampling pumps, thereby preventing contamination of the sample. This…
-
Chlordane
Restek• Compound: chlordane • CAS #: 57-74-9 • Conc. in Solvent and Volume: 1,000 µg/mL in hexane, 1 mL/ampul
-
Ideal for dirty samples. Spiral bore prevents nonvolatile residue from contaminating the column. Visually observe the Press-Tight connection between the column end and liner Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm) Slotted top prevents obstruction of…
-
Topaz GC inlet liners feature revolutionary technology and inertness to deliver you the next level of True Blue Performance: Deactivation —unbelievably low breakdown for accurate and precise low-level GC analyses Reproducibility —unbeatable manufacturing controls and QC…
-
Compound List Chain, Compound (CAS#), % by Weight C4:0 Methyl butyrate (632-42-7), 1.5% C6:0 Methyl hexanoate (106-70-7), 1.5% C8:0 Methyl octanoate (111-11-5), 2% C10:0 Methyl decanoate (1110-42-9), 2.5% C11:0 Methyl undecanoate (1731-86-8), 2.5% C12:0 Methyl laurate (111-82-0), 5% C13:0 Methyl…
-
-
Molecular Sieve Columns
RestekMolecular sieve packed columns easily separate permanent gases at above-ambient temperatures. Restek’s R&D chemists have developed a process for preparing molecular sieve packings, which results in excellent batch-to-batch reproducibility. In addition, our molecular sieves are…
-
Compound List (C17) n-Heptadecane (629-78-7) (C19) n-Nonadecane (629-92-5) Aniline (62-53-3) 2-Chlorophenol (95-57-8) 2-Dodecanol (10203-28-8) Methyl dodecanoate 2-Nonanone (821-55-6) 1-Octanol (111-87-5)
-
polar phase; Crossbond polyethylene glycol Restek’s polar-deactivated surface tightly binds the Carbowax polymer and increases thermal stability, relative to competitive columns. Because of the increased stability produced by the bonding process, Stabilwax columns exhibit long column…
-
Click-On connectors allow you to change traps quickly, without introducing oxygen into your system.
-
Ready to use for QuEChERS extractions—no dilutions necessary.