PerkinElmer Gas Chromatography Tools
-
Indicates that SCHOTT type UK 5 is used for cells referred to in the catalog as manufactured from “Special Optical Glass”. This crown glass is made from exceptionally pure raw materials, which gives an improved transmission in the near ultraviolet range. An empty cell will give a transmission of…
-
The Calcium Fluoride Semi-Demountable Cell Kit from PerkinElmer includes windows and Teflon spacers which vary by thickness (0.025- 1.0 mm).
-
Reduction Tube for CHN Analysis, Quartz
PerkinElmerPerkinElmer reduction tubes are composed of pure fused quartz which is 99% SiO2. Fused quartz has been chosen because of its very high purity and low thermal expansion rate. Because we care about your safety, all combustion tubes are pressure-tested to eliminate any tubes which might contain weak…
-
Standard rectangular Macro cells are the most common type of spectroscopy cell and are used for routine UV/VIS analysis. Each cell has a standard inside width of 9.5 mm and a base thickness of 1.5 mm. All Macro cells contain two clear windows.
-
Gas Chromatography Male Fitting
PerkinElmerThe PerkinElmer 1/16 Inch gas chromatography male fitting comes with a 10-32 thread that offers great connection and the brass construction offers added strength.
-
Swivel tip for high pressure clamps for the Spectrum Two
-
Standard rectangular Macro cells are the most common type of spectroscopy cell and are used for routine UV/VIS analysis. Each cell has a standard inside width of 9.5 mm and a base thickness of 1.5 mm. All Macro cells contain two clear windows.
-
20 mm NIR Rectangular Cell with PTFE Stopper, Quartz SUPRASIL 300,Light Path: 20 mm, Outside Dim: 46H x 12.5W x 22.5D mm, InsideWidth: 9.5 mm, Base Thickness: 1.5 mm, Cell Volume: 7.0 mL,contains two clear windows, Pkg 2. PerkinElmer offers acomprehensive range of NIR Cells, Cell Holders and…
-
Inject from 1 µL to 5 mL with high accuracy and precision, with the Rheodyne 7725 and 7725i valves. Rheodyne 7725 and 7725i valves are versatile injectors and can use both partial-filling and complete-filling methods for loading the sample loop. Wide port angles of the 7725/7725i valve provide…
-
GladiATR Heated ATR Diamond up to 210C
PerkinElmerThe GladiATR Vision™ is a sampling tool which couples small area infrared analysis with simultaneous viewing. Samples are placed face down and positioned on the diamond crystal while its image is projected in real-time on the LCD screen. Finding and optimizing the sample placement for specific…
-
-
By using rectangular windows instead of circular windows, the demountable cell becomes a semi-demountable cell. The semi-demountable cell can be used either as a demountable cell or as a sealed cell for high-viscosity liquids or mull samples. To order a semi-demountable cell, order the Universal…
-
ICP-OES Oil-less Air Compressor, 115V/60HZ
PerkinElmerHorse Power: 1.5 Hp Output CFM/Output L.: 6.0 CFM/170 L. Min Max Pressure PSI/Max Pressure Bar: 120 PSI/8 bar Noise Level: 72 dB/A, with Enclosure 55 dB/A Tank Size Gal./Tank Size L: 13 Gallons/50 Liters Dimensions: 25 x 18 x 29 / with Enclosure 29 x 23 x 32 Weight: 97 Lbs. / with…
-
General Purpose Optical Bench
PerkinElmerThe PerkinElmer optical bench is perfect for holding optical instruments for experimentation and is also used for general-purpose applications.
-
LC Standard Analytical Flowcell
PerkinElmerThe PerkinElmer LC standard analytical flow cell measuring 8 mm x 12 uL is designed to use with UV/vis detectors.
-
Replacement Seal
PerkinElmerThe PerkinElmer replacement seal is designed to use with bio-compatible titanium inline solvent filter.
-
NITROGEN NITROFLOW LAB Generator 120volt
PerkinElmerThe Nitroflow Lab is a portable unit that offers a less expensive and more convenient delivery of nitrogen than cylinders and dewars. NitroFlow lab is a self contained LC/MS Membrane Nitrogen Generator with dual oil-less air compressors. NITROFLOW LAB Integrated Nitrogen Generator. System Includes…
-
Alumina Sample Pans and Covers
PerkinElmerUsed for oxidation studies of metals, minerals, ceramics, clays and soils. They can also be used for melting and eutectic diagrams in the metals industry. The covers are pierced. A crimper is not required.
-
-
Sodium Chloride Rectangular Sealed Liquid Cells are available from PerkinElmer for FT-IR analysis of highly volatile samples.
-
-
-
Biocompatible Piston Seal Replacement Kit
PerkinElmerThe PerkinElmer piston seal replacement kit contains four seals, backup rings and O-rings and meets the bio-compatible standards of the industry.
-
Requires but does not include, Transfer-Optic for Mono-Fibers, Light Shield (N1016074), and one of the following Probe Tips: Probe Tip, 2 mm pathlength (N1016073); Probe Tip, 5 mm pathlength (N1016072); or Probe Tip, 10 mm pathlength (N1016071).
-
A complete High-Sensitivity plastic body nebulizer with tantalum capillary and Kalrez o-rings. Recommended for use with aqueous or organic solutions including aqua regia. This nebulizer is compatible with the PinAAcle 500 and 900F/H/T AA instruments.
-
Viton O-Ring, 0.364in i.d., 0.070in. width
PerkinElmerFor use with Silicone Applications. For Spacer please order Part No. B3150531
-
Nitrogen Generator 30 liter Per Minute 120 Volt
PerkinElmerFive models operate at flow rates from 15 L/min to 50 L/min. The LCMS generators provide a continuous stream of high purity nitrogen from a single ‘plug play’ unit. Models are available with and without an integral oil free compressor, are extremely quiet in operation and are fully approved for use…
-
Recommended as a source of high purity nitrogen purge gas. Nitrogen is separated from ambient air by a patented pressure swing adsorption process using a carbon molecular sieve (CMS) to differentially absorb oxygen, carbon dioxide, water vapor, etc.
-
AA and ICP Vent and Blower Kit - 115V
PerkinElmerNotice: Local electrical codes do not permit PerkinElmer Service Engineers to install the blower and vent assembly.
-
Peristaltic Pump Head
PerkinElmerThe PerkinElmer peristaltic pump head comes with a stainless steel roller and is compatible to use with Optima 2000/4000 spectrometers.
-
A complete High-Sensitivity plastic body nebulizer with Pt/Ir capillary and Kalrez o-rings. Recommended for use with aqueous or organic solutions. This nebulizer is compatible with the PinAAcle 500 and 900F/H/T AA instruments.
-
Helium or Argon Gas Regulator
PerkinElmerThis two-stage regulator has a brass body and stainless steel diaphragm and guarantees constant delivery pressure regardless of variations in cylinder pressure. Maximum inlet pressure is 3000psi, and the CGA fitting size is 580. A Swagelok™ 1/4in npt to 1/8in fitting (P/N 09903471) is included.…