LaMotte Water Quality

Compare Tool

Select up to 3 products

1 - 32 of 114
Sort
View
Show
  • Tests 0-5 ppm Five intervals: 0, 0.5, 1, 3 and 5 50 strips per vial Unique range and sensitivity covers critical chlorine concentrations for many applications of food processing, water/wastewater treatment, education and other areas.

  • Insta-TEST® Chlorine Dioxide is a convenient way to test for Chlorine Dioxide levels in sanitized water. Range and sensitivity is 0, 10, 25, 50, 100, 250, 500 ppm. Range and sensitivity is 0, 0.25, 0.5, 1, 3, 10 ppm.

  • This kit tests for Sodium Nitrite using the Direct Reading Titrator method. Applications: Industrial Water Boiling and Cooling, Water and Wastewater Range/sensitivity is 0-1000 ppm/20 ppm NaNO2

  • This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • LaMotte

    Wide Range Octet Comparator Method Employ Octet Comparator having eight color standards in increments of 5.0 or 1.0 pH unit, as indicated in listings below Kits are offered covering ranges from pH 3.0-10.0 to pH 8.5-12.0 For each pH range, two kits are offered: one without and one…

  • 4507 Drop Count Method For determining anionic forms of detergent One drop equals 1.0 ppm detergents; range approximately 0 to 5.0 ppm Sufficient for 60 tests at 5.0 ppm

  • Octet Comparator Method For determining cadmium in water using Dithizone method; commonly occurs from the deterioration of galvanized pipe Octet comparator has color standards representing 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 and 1.0 ppm cadmium. For use only where organic matter is absent and…

  • 3322 Octa-Slide Comparator System For determining total sulfide Sufficient for 50 tests NPDES-EPA accepted Unit uses the Pomeroy methylene blue method for analysis. Total sulfide is determined using a color dye, which is added to an un-reacted sample until it matches a reacted…

  • LaMotte

    Octet Comparator For detection of nickel in waste effluents and water supplies Employs dimethylglyoxime method Octet Comparator has color standards representing 0.5, 1.0, 2.0, 4.0, 5.0, 7.5, and 10.0 ppm nickel Sufficient for 20 tests

  • Direct Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL   All-purpose…

  • Direct Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…

  • Octet Comparator Method For determining hexavalent, trivalent, and total chromium Octet comparator has color standards representing 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2 and 1.5 ppm Cr Sufficient for 20 tests Test requires suitable hot plate, not included Reagent Refill only. …

  • The Iodine test papers are a convenient way to test Iodine in water with fast results. Range and sensitivity is 0, 30, 60, 120, 180 ppm.

  • LaMotte

    The special rugged POOL MGR. kit series is for the public pool operator. The precise Octa-Slide 2 comparator system is used to comply with regulatory standards. The POOL MGR. series includes diagrammed instructions, saturation index calculator, water quality handbook, and the reliable Octa-Slide 2…

  • Yes/No qualitative test Sensitivity less than 2.2 per 100 mL of sample No incubation equipment required; only room temperature

  • Tests the quality of water, these nitrate #1 tablets are part of the nitrate-nitrogen kit.

  • LaMotte

    Test for 7 Essential Factors Chloride Sulfate Alkalinity Total Hardness Calcium Hardness Magnesium Hardness Sodium

  • LaMotte

    Direct Reading Titrator For determining levels of sodium in natural and treated waters Range 0 to 500 ppm sodium in 10 ppm increments Test requires three titrations: one to determine bicarbonate and carbonate ions; one to determine sulfate and chloride ions; and one to determine calcium and…

  • LaMotte

    Octet Comparator For determining silica in natural and industrial waters Employs modified APHA Method 425D Octet Comparator has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0 and 10.0 ppm silica Sufficient for 50 tests

  • No color matching, no look up charts, no guessing! The unique, multi-test ColorQ pool and spa hand-held photometer reads SEVEN test factors (Free Chlorine, Total Chlorine, Bromine, pH, Alkalinity, Calcium Hardness, and Cyanuric Acid) directly on a digital display. Featuring an innovative…

  • A complete outfit for pond fish culture, ideal for fresh water analysis. Nine critical test factors can be efficiently and accurately determined on-site. Designed with field analysis as a priority; all reagents, components and accessories are arranged in pre-drilled ethafoam. Short form…

  • Come in a 60 mL quantity, this performance check standard is for inspection and monitoring water quality.

  • This LaMotte Phosphate test kit tests for low range Phosphate using the LRC Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43-. Applications: Environmental Education

  • This kit tests for nitrate nitrogen using the LRC Comparator. Range/sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3--N. Applications: Food and Beverage, Environmental Education, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater

  • Applications: Industrial Water Boiling and Cooling, Water and Wastewater This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.

  • No. 7436-01 Determines corrosion conditions in water supplies which can introduce lead and heavy metals Supports a water supplier’s lead abatement program in drinking water Includes TDS pocket tester to meet EPA requirements for corrosion testing Packaged in a portable…

  • DPD Tablet Octa-Slide (9859G42) Sufficient for 50 tests Employs DPD tablet method: EPA- accepted method for NPDWR Octa-Slide has color standards representing 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 and 3.0 ppm Cl Low Range Octet Comparator (9859H10) Employs DPD tablet…

  • The LaMotte 0 - 15 ppm ColorQ nitrate TesTabs are suitable for use with ColorQ and ColorQ 2x test kits. They are mainly used in research facilities and chemical laboratories to conduct wide range of experiments. They are easy and convenient to use.

  • Applications: Drinking Water, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater 2951HR High Range QAC test papers are specifically formulated to read high range levels of QAC. Range and sensitivity is 200, 400, 600, 1000, 1500 ppm.

  • Contents: 30 mL Hydrogen Peroxide 3% 30 mL Chloride Reagent A 30 mL Sulfuric Acid, 0.5N 15 mL Phenolphthaein Indicator 0.5% 2 x 30 mL Silver Nitrate 0.171 N 1 Sample Tube, 5-10-25 mL w/ cap  

  • The LaMotte 30 mL sample bottle with flip top is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is made of sturdy plastic material which ensures long lasting usage.

  • The LaMotte DPD chlorine secondary standard kit is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is available in sturdy bottle that endures heavy and rigorous usage.