Water Quality Test Kits

Compare Tool

Select up to 3 products

HomeAll Products

Water Quality Water Quality Test Kits

1 - 32 of 472
Sort
View
Show

  • DPD Chlorine Tablets

    LaMotte

    Most Widely used DPD Chlorine Tablets for Determining Free and Combined Chlorine DPD chlorine tablets employ DPD indicator (diethyl-p- phenylenediamine) to distinguish levels of free, combined, and total chlorine in a simple test sample. DPD chlorine tablets designated “Instrument…

  • Chlorine Test Kit

    LaMotte

    This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • Total Hardness Test Kit (Dropper Bottle method)

    LaMotte

    This kit tests for Calcium and magnesium hardness by using the Dropper Bottle method. All results are as CaCO3. Range/sensitivity is 1 drop = 10 ppm or 1 gpg CaCO3. Applications: Industrial Water Boiling and Cooling, Water and Wastewater # Tests (# Rgts): 50 at 200…

  • Test Kit Nitrite Sodium

    LaMotte

    This kit tests for nitrite using the direct reading titrator method. Range/sensitivity is 0-1000 ppm/20 ppm NaNO2 Applications: Industrial Water Boiling and Cooling, Water and Wastewater

  • Dissolved Oxygen Test Kits

    LaMotte

    Direct Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter checkups and…

  • Dissolved Oxygen CHEMets® Kits

    CHEMetrics

    The level of dissolved oxygen in natural waters is often a direct indication of quality, since aquatic plants produce oxygen, while microorganisms generally consume it as they feed on pollutants. At low temperatures the solubility of oxygen is increased; during summer, saturation levels can be as…

  • TB 250 Portable Turbidimeter

    Lovibond

    For measuring water turbidity (cloudiness) according to either EPA or ISO Standards Easy Calibration and Operation Auto Ranging from 0-1100 NTU Simple 5 key operation Signal Averaging for stable and accurate readings Long Battery and Bulb Life Portable for use either in the…

  • Total Iron Test Kit

    LaMotte

    Octa-Slide Comparator Tests total iron after any ferric iron is reduced to ferrous in the sample Sufficient for 90 tests Ferrous and ferric iron may be tested separately by eliminating the reduction step. Octa-Slide has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0…

  • Water Hardness Single Parameter Test Kit

    Hach

    Water hardness is caused almost entirely by calcium and magnesium ions. Other di- and trizalent metals have a similar effect, but usually are not present in high enough concentration in potable waters to cause problems. Hardness increases soap consumption in laundries and causes scale in boilers. …

  • Ammonia TNTplus, HR

    Hach

    For determination of Ammonia Nitrogen by the Salicylate Method, using TNTplus vials. Hach Method 10205. High Range: 2 - 47 mg/L NH3-N. ?25 tests/package. Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design

  • Nitrogen, Nitrate Test Kits

    Hach

    Normally found in water and soil as ammonia (NH3), nitrate (NO3), and nitrite (NO2), nitrogen is an indispensable part of the life cycle. However, concentrations above certain levels can present problems. Thomas No. 3241S80 Utilizing the simple color…

  • Formaldehyde VACUettes Kit, Range: 0-120 & 120-1200 ppm

    CHEMetrics

    Formaldehyde, a toxic substance, is used in the following applications: metal plating baths, textile treatments, biological specimen preservatives, and disinfectants of medical equipment. Commercial formaldehyde gas is readily soluble in water. The Purpald Method Reference:…

  • Ammonia Nitrogen Test Kits

    LaMotte

    Octet Comparator Method (9859C70 and C71) For determining ammonia nitrogen in water using Nessler method Octet Comparator has color standards representing 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 ppm ammonia nitrogen Sufficient for 50 tests Octa-Slide Comparator Method…

  • MQuant™ Lead Test, Test Method: colorimetric with test strips and reagent

    MilliporeSigma

    Method: colorimetric with test strips and reagent 20 - 40 - 100 - 200 - 500 mg/l Pb MQuant™ Storage class: 10 - 13 Other liquids and solids Storage: Store at +15°C to +25°C. The lead test is suitable in environmental analysis. Not only in all aqueous media but also…

  • Color Q Pro 7 Pool Kits, Tabs

    LaMotte

    Photometer directly measures seven pool & spa tests which includes Free Chlorine, Total Chlorine, Bromine, pH, Alkalinity, Calcium Hardness and Cyanuric Acid. The photometer is easy to use and includes 100 TesTabs® tablet reagents per test factor packaged in blister-style foil. …

  • Iron Test Kits

    LaMotte

    Octet Comparator For determining total iron (dissolved, suspended and collodial) in natural waters Octet Comparator has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0 and 10 ppm iron Bipyridyl indicator Sufficient for 100 tests Octet Comparator For determining trace…

  • SL1000 Portable Parallel Analyzer (PPA)

    Hach

    Water Quality Testing. Dramatically Streamlined. The Hach SL1000 Portable Parallel Analyzer (PPA) performs the same tests with less than half the manual steps. Get highly accurate results, with less opportunity for errors, in a fraction of the time. Up to six parameters, tested…

  • BrewLab™ Test Kit

    LaMotte

    The BrewLab™ test kit for Home Brewers quantifies 6 important test factors. Included is a digital pH meter for monitioring batches from start to finish. Experts agree water conditions affect your final product, so take the mystery out of great beer. Trust LaMotte, the water analysis experts…

  • MQuant™ Arsenic, Test Method: colorimetric with test strips and reagents

    MilliporeSigma

    Method: colorimetric with test strips and reagents 0.02 - 0.05 - 0.1 - 0.2 - 0.5 mg/l As 0.1 - 0.5 - 1.0 - 1.7 - 3.0 mg/l As MQuant™ UN Number: UN3316 Storage class: 10 - 13 Other liquids and solids Storage: Store at +15°C to +25°C. Hazard: Irritant;…

  • Hardness Test Kits

    LaMotte

    Direct Reading Titrator (9859X42 and X43) For determining total hardness of water Range 0 to 200 ppm as CaCO3 in 4 ppm increments Titrators may be refilled to test higher concentrations Sufficient for 50 tests at 200 ppm Direct Reading Titrator (9859X72 and X73) For…

  • Spectroquant® Surfactants (nonion.) Cell Test Method: photometric

    MilliporeSigma

    UN Number: UN3316

  • Nitrate Nitrogen Test Kits

    LaMotte

    This kit tests for nitrate nitrogen using the LRC Comparator. Range/sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3--N. Applications: Food and Beverage, Environmental Education, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater

  • WaterWorks™ EZ Coliform Cult Bacteria

    Industrial Test Systems

    Industrial Test Systems, Inc. offers the EZ Coliform Cult (XGAL/MUG) EPA compliant test. When using this simple test the media turns blue-green in the presence of coliform bacteria. E. coli growth is confirmed by blue fluorescence under UV light or using a Kovacs reagent. Total coliform…

  • Chlorine Bleach Test Kit

    LaMotte

    Applications: Industrial Water Boiling and Cooling, Water and Wastewater This test kit measures for Chlorine Bleach using the Direct Reading Titrator method. Range/sensitivity is 00-10%/0.2% Cl.

  • Caustic Test Kit

    LaMotte

    Applications: Laundry and Sanitation This kit tests for caustic levels by adding drops of Barium Chloride solution to a sample where white precipitate will form if carbonates are present. Levels are then determined using the Phenolphthalein Indicator. Range and sensitivity is 1 drop = 0.1 or…

  • Spectroquant® Chlorine reagent Cl2-1 (liquid) for chlorine test (DPD) 0.010 - 6…

    MilliporeSigma

    Solubility: (20°C) soluble Density: 1.25 g/cm3 (20°C)

  • Nitrate TNTplus, HR

    Hach

    Now USEPA approved for compliance monitoring under the Safe Drinking Water Act. For determination of Nitrate Nitrogen by the Dimethylphenol Method, using TNTplus vials. Hach Method 10206. High Range: 5-35 mg/L NO3-N (22-155 mg/L NO3). 25 tests/package Reduce Errors with Bar-coded Vials No…

  • Color Test Kit, Octet Comparator

    LaMotte

    For determining color in water Tests an unlimited number of reagents The color of water is measured by comparing the water to platinum cobalt color standards representing APHA Standard Color Units. Tests 0, 20, 50, 80, 110, 140, 170, and 200 APHA color units.

  • Detergent Test Kit

    LaMotte

    4507 Drop Count Method For determining anionic forms of detergent One drop equals 1.0 ppm detergents; range approximately 0 to 5.0 ppm Sufficient for 60 tests at 5.0 ppm

  • WaterSafe Lead Water Test Kit

    Industrial Test Systems

    Tests for the EPA limit of 15 ppb (μg/L) Lead in water The Lead Water Test for water quality testing is a revolutionary product designed to make testing for Lead safe, easy, and affordable. This patent pending device utilizes a lateral flow test strip, similar in technology to home…

  • Chromium Test Kit

    LaMotte

    Octet Comparator Method For determining hexavalent, trivalent, and total chromium Octet comparator has color standards representing 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2 and 1.5 ppm Cr Sufficient for 20 tests Test requires suitable hot plate, not included

  • Hydrogen Peroxide SAM Kit

    CHEMetrics

    Hydrogen peroxide is a strong oxidizing agent with a variety of uses. Applications include the treating of industrial effluents and domestic waste and serving as a disinfectant in aseptic packaging. The Ferric Thiocyanate Method Reference: D. F. Boltz and J. A. Howell, eds.,…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.