Water Quality Test Kits
-
Microtox® LX Series Analyzers
Modern WaterModern Water is expert in the design, development and provision of analytical instruments and technologies for monitoring toxicity in water, soil, food and industry. Our systems use bioluminescent bacteria to perform biosensor testing that detects the presence of toxic substances. The new…
-
Color of Water Sets
LovibondA method for measuring the color of potable water in terms of an easily reproducible color standard is essential to water engineers responsible for the distribution of supplies for public consumption. Color determinations are useful for detecting any irregular contamination of the supply due…
-
Chlorine Testing Dispenser
HF ScientificDPD Powder Pop® Dispenser with tests for Chlorine Compact and convenient Redesigned dispenser prevents clogging Dispense into round or square cuvettes Push button operation for precise dosing Portable dispensers accurately deliver the correct volume of DPD reagent for…
-
Arium Consumables & Accessories
SartoriusConsumables & accessories for Sartorius Arium laboratory water systems. Arium® Smart Station flexible remote dispenser Ultrapure Water for benchtop or wall-mounted installation. The Arium® Smart Station is designed for flexible remote dispensing of ultrapure water directly at the…
-
Water hardness is caused almost entirely by calcium and magnesium ions. Other di- and trizalent metals have a similar effect, but usually are not present in high enough concentration in potable waters to cause problems. Hardness increases soap consumption in laundries and causes scale in boilers. …
-
Total Hardness Test Kit
LaMotteApplications: Industrial Water Boiling and Cooling, Water and Wastewater This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.
-
Reflectoquant® Ammonium Test
MilliporeSigmaThe test measures both ammonium ions and dissolved ammonia in e.g. groundwater and surface water, seawater, drinking water and aquarium water.
-
UN Number: UN3316
-
ColorQ® 2x PRO 7-PLUS Kit
LaMotteThe waterproof, Bluetooth ® ColorQ ® 2x PRO 7-PLUS Kit handheld professional pool photometer directly measures the seven primary tests of Free Chlorine (DPD), Total Chlorine (DPD), Bromine (DPD), pH, Alkalinity, Calcium Hardness, and Cyanuric Acid directly on a digital display. The…
-
For determination of reactive (ortho) phosphate (phosphorus) by the PhosVer® 3 ascorbic acid method. USEPA accepted for reporting for wastewater analysis using Hach Method 8048, Phosphorus, Reactive. Also used in acid-hydrolyzable and total phosphorus determination, after…
-
Glycol CHEMets Kit
CHEMetricsEthylene glycol and propylene glycol are the primary ingredients in commercially-available antifreezes. They are used with various corrosion inhibitors to protect metal surfaces in cooling water systems. CHEMetrics glycol kits are used to monitor potable waters for glycol contamination…
-
Total Iron Test Kit
LaMotteOcta-Slide Comparator Tests total iron after any ferric iron is reduced to ferrous in the sample Sufficient for 90 tests Ferrous and ferric iron may be tested separately by eliminating the reduction step. Octa-Slide has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0…
-
Phosphate Vacu-vials® Kits
CHEMetricsPhosphorus occurs naturally in rock formations in the earth's crust, usually as phosphate. High phosphate concentrations in surface waters may indicate fertilizer runoff, domestic waste discharge, or the presence of industrial effluents or detergents. Although phosphates from these sources are…
-
Cyanide (Free) CHEMets Kit
CHEMetricsCyanide is used in many chemical and refining processes. It is found in effluent from electroplating and metal cleaning operations, coke ovens, steel manufacturing facilities, and gas scrubbers. Although cyanide can be safely removed by alkaline chlorination, its acute toxicity to aquatic life…
-
Aluminum Test Kit
LaMotteOctet Comparator Method For determining aluminum in water Sufficient for 50 tests Octet Comparator has color standards representing 0, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4 and 0.5 ppm. A pink to red color will form when aluminum reacts with Eriochrome Cyanine R, at pH 6.
-
TB 250 Portable Turbidimeter
LovibondFor measuring water turbidity (cloudiness) according to either EPA or ISO Standards Easy Calibration and Operation Auto Ranging from 0-1100 NTU Simple 5 key operation Signal Averaging for stable and accurate readings Long Battery and Bulb Life Portable for use either in the…
-
Peracetic Acid Kit
LaMotteThe hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence.
-
BrewLab® Pro Water Analysis Kit
LaMotteLaMotte introduces the new BrewLab® Pro water analysis kit. Designed with the professional brewer in mind, this kit measures 11 test factors which are important in the brewing process. Water is the most important ingredient for any brewer. The BrewLab® Pro helps you to make your best craft…
-
-
Ammonia Nitrogen Test Kits
LaMotteOctet Comparator Method (9859C70 and C71) For determining ammonia nitrogen in water using Nessler method Octet Comparator has color standards representing 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 ppm ammonia nitrogen Sufficient for 50 tests Octa-Slide Comparator Method…
-
Detergent Test Kit
LaMotte4507 Drop Count Method For determining anionic forms of detergent One drop equals 1.0 ppm detergents; range approximately 0 to 5.0 ppm Sufficient for 60 tests at 5.0 ppm
-
The LaMotte Stormwater MS4 Kit has instrumentation and reagent systems to provide a preliminary screening of stormwater outflow, and to determine whether it is contributing to the overall pollutant load from precipitation events. Meets guidance as set forth by USEPA. Features …
-
2nd Generation ATP Test Kits
Modern WaterLuminultra’s 2nd Generation ATP kits provide fast, complete, and accurate insight into microbiological activity. Both portable and easy to use, the test kits provide an interference-free indication of total microbial quantity within minutes of sample collection allowing you to save valuable…
-
Iron CHEMets Kit
CHEMetricsIron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…
-
Salinity Test Kit
LaMotteFor determining salinity (as chloride content) of water Employs modified APHA Argentometric method Range of 0 to 20 ppt salinity in 0.4 ppt increments Sufficient for 50 tests at 20 ppt
-
Phosphate Test Kit
LaMotteThis kit tests for Phosphate using the Octa-Slide 2 Comparator. Range is 1.0 - 10.0 ppm (PO4) and 10 - 100 ppm (PO4). Applications: Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater
-
Combination Water Kit
LaMottePopular AR-02 outfit provides tests for Hardness, Iron, and pH. Drop count tests for Hardness (10 ppm or 1 gpg/drop) Octa-Slide tests for Iron (0.5-10 ppm) and pH (5.0-10) Includes 100 tests for Iron and 50 tests for each pH and Hardness
-
Insta-Test® PRO Phosphate
LaMotteInsta-Test® PRO Phospate strip measures the Phosphate levels from 0, 100, 200, 300, 500, 1000, and 2500 ppb in 15 seconds. The PRO Phosphate strips are packaged 50 strips per bottle in a 6-pack case.
-
Caustic Test Kit
LaMotteApplications: Laundry and Sanitation This kit tests for caustic levels by adding drops of Barium Chloride solution to a sample where white precipitate will form if carbonates are present. Levels are then determined using the Phenolphthalein Indicator. Range and sensitivity is 1 drop = 0.1 or…
-
Cadmium Test Kit
LaMotteOctet Comparator Method For determining cadmium in water using Dithizone method; commonly occurs from the deterioration of galvanized pipe Octet comparator has color standards representing 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 and 1.0 ppm cadmium. For use only where organic matter is absent and…
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-60 & 60-600 ppm MDL: 10 ppm Method: Direct Nesslerization …
