LaMotte Portable Water Quality Test Kits

Compare Tool

Select up to 3 products

HomeAll Products

LaMotte Water Quality Water Quality Test Kits

1 - 32 of 102
Sort
View
Show
  • DPD Tablet Octa-Slide (9859G42) Sufficient for 50 tests Employs DPD tablet method: EPA- accepted method for NPDWR Octa-Slide has color standards representing 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 and 3.0 ppm Cl Low Range Octet Comparator (9859H10) Employs DPD tablet…

  • This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • Yes/No qualitative test Sensitivity less than 2.2 per 100 mL of sample No incubation equipment required; only room temperature

  • Direct Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…

  • LaMotte

    Octet Comparator For determining zinc in cooling waters Octet Comparator has color standards representing 0, 1, 2, 3, 4, 6, 8 and 10 ppm zinc Employs buffered zincon reagent system Sufficient for 50 tests

  • LaMotte

    Octet Comparator For determining silica in natural and industrial waters Employs modified APHA Method 425D Octet Comparator has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0 and 10.0 ppm silica Sufficient for 50 tests

  • Direct Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL   All-purpose…

  • Applications: Industrial Water Boiling and Cooling, Water and Wastewater This kit tests for Total Hardness using the Dropper Bottle Method. All results are as CaCO3. Range/sensitivity is 1 drop = 2, 5, or 10 ppm CaCO3.

  • A complete outfit for pond fish culture, ideal for fresh water analysis. Nine critical test factors can be efficiently and accurately determined on-site. Designed with field analysis as a priority; all reagents, components and accessories are arranged in pre-drilled ethafoam. Short form…

  • Applications: Laundry and Sanitation This kit tests for caustic levels by adding drops of Barium Chloride solution to a sample where white precipitate will form if carbonates are present. Levels are then determined using the Phenolphthalein Indicator. Range and sensitivity is 1 drop = 0.1 or…

  • This kit tests for Sodium Nitrite using the Direct Reading Titrator method. Applications: Industrial Water Boiling and Cooling, Water and Wastewater Range/sensitivity is 0-1000 ppm/20 ppm NaNO2

  • 3322 Octa-Slide Comparator System For determining total sulfide Sufficient for 50 tests NPDES-EPA accepted Unit uses the Pomeroy methylene blue method for analysis. Total sulfide is determined using a color dye, which is added to an un-reacted sample until it matches a reacted…

  • Octet Comparator Method (9859C70 and C71) For determining ammonia nitrogen in water using Nessler method Octet Comparator has color standards representing 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 ppm ammonia nitrogen Sufficient for 50 tests Octa-Slide Comparator Method…

  • No. 7436-01 Determines corrosion conditions in water supplies which can introduce lead and heavy metals Supports a water supplier’s lead abatement program in drinking water Includes TDS pocket tester to meet EPA requirements for corrosion testing Packaged in a portable…

  • Applications: Drinking Water, Environmental Education, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater

  • Applications: Drinking Water, Industrial Water Boiling and Cooling, Water and Wastewater This Alkalinity Test Kits uses a Direct Reading Titrator with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 0–200 ppm as CaCO3 in 4 ppm…

  • Most Widely used DPD Chlorine Tablets for Determining Free and Combined Chlorine DPD chlorine tablets employ DPD indicator (diethyl-p- phenylenediamine) to distinguish levels of free, combined, and total chlorine in a simple test sample. DPD chlorine tablets designated “Instrument…

  • The LaMotte DPD chlorine secondary standard kit is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is available in sturdy bottle that endures heavy and rigorous usage.

  • Octet Comparator Method For determining cadmium in water using Dithizone method; commonly occurs from the deterioration of galvanized pipe Octet comparator has color standards representing 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8 and 1.0 ppm cadmium. For use only where organic matter is absent and…

  • LaMotte calcium hardness reagent - 30 mL is a liquid reagent for swimming pool water testing.

  • For determining available chlorine in chlorine bleach or hypochlorite solutions Range: 1 drop = 0.005%, 0.05% or 0.5% Cl Sufficient for 50 tests at 0.1, 1.0 or 10%

  • For determining salinity (as chloride content) of water Employs modified APHA Argentometric method Range of 0 to 20 ppt salinity in 0.4 ppt increments Sufficient for 50 tests at 20 ppt 

  • This LaMotte Phosphate test kit tests for low range Phosphate using the LRC Comparator. Range and sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.5, 2.0 ppm PO43-. Applications: Environmental Education

  • Direct Reading Titrator (9859X42 and X43) For determining total hardness of water Range 0 to 200 ppm as CaCO3 in 4 ppm increments Titrators may be refilled to test higher concentrations Sufficient for 50 tests at 200 ppm Direct Reading Titrator (9859X72 and X73) For…

  • The LaMotte nitrate #2 CTA tablet is suitable for use in research facilities and chemical laboratories to conduct wide range of experiments. It is available in sturdy bottle that endures heavy and rigorous usage.

  • Applications: Industrial Water Boiling and Cooling, Water and Wastewater This test kit measures for Chlorine Bleach using the Direct Reading Titrator method. Range/sensitivity is 00-10%/0.2% Cl.

  • Octa-Slide Comparator Tests total iron after any ferric iron is reduced to ferrous in the sample Sufficient for 90 tests Ferrous and ferric iron may be tested separately by eliminating the reduction step. Octa-Slide has color standards representing 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0…

  • Contents: 30 mL Hydrogen Peroxide 3% 30 mL Chloride Reagent A 30 mL Sulfuric Acid, 0.5N 15 mL Phenolphthaein Indicator 0.5% 2 x 30 mL Silver Nitrate 0.171 N 1 Sample Tube, 5-10-25 mL w/ cap  

  • This kit tests for Total Hardness by using the Direct Reading Titrator Method. All results are as CaCO3. Range/sensitivity is 0-200 ppm/4ppm CaCO3. Applications: Industrial Water Boiling and Cooling, Water and Wastewater # Tests (# Rgts): 50 at 200 ppm (3)

  • The hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence.

  • This kit tests for nitrite using the direct reading titrator method. Range/sensitivity is 0-1000 ppm/20 ppm NaNO2 Applications: Industrial Water Boiling and Cooling, Water and Wastewater

Compare Tool