Portable Water Quality Test Kits
They are invaluable when measuring the pH levels of water, which measures the acidity and alkalinity of the water and is important for assessing if water is suitable for drinking, agricultural, or industrial processes. Monitor the chlorine levels to ensure all water is disinfected correctly and safe for consumption.
Some water quality test kits can also identify the presence of harmful bacteria, which are indicators of water contamination and potential health risks.
Portable water testing kits are available in multiple forms, including test strips, chemical reagent kits, and more. Suitable for different types of water sources, including drinking water, pool, or environmental monitoring applications.
-
Ozone SAM Kit
CHEMetricsOzone is a strong oxidizing agent and is used as an alternative to chlorine as a biocide in the disinfection of drinking water. Ozone is used to remove odor, decolorize, and to control algae and other aquatic growths. Ozone is also used in various disinfectant and sterilization processes in…
-
BrewLab® Basic
LaMotteTest for 7 Essential Factors Chloride Sulfate Alkalinity Total Hardness Calcium Hardness Magnesium Hardness Sodium
-
Direct Reading Titrator (9859K40 and K41) For determining high range chlorine in water Range of 0 to 200 ppm Cl2 in 4 ppm increments Sufficient for 50 tests at 200 ppm. Uses Iodometric reagent method.
-
All necessary reagents for the analysis are contained in the cells Considerate packaging design protects the cells from fluctuation even in unfavorable environment Elimination of possible mistakes through barcode-system
-
Spectroquant® Chloride Test Method: photometric
MilliporeSigmaPrecautionary Statement(s): P273: Avoid release to the environment. P280: Wear protective gloves/ protective clothing. P302 + P352: IF ON SKIN: Wash with plenty of soap and water. P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if…
-
This kit tests for nitrate nitrogen using tablet reagents and the Octa-Slide 2 Comparator. Range/sensitivity is 0, 1, 2, 4, 6, 8, 10, 15 ppm NO3 - -N Applications: Drinking Water, Environmental Education, Food and Beverage, Industrial Water Boiling and Cooling,…
-
Chlorine (Free & Total) CHEMets® Kits
CHEMetricsBecause of its strong oxidizing properties, chlorine is an excellent biocide used to treat potable waters, municipal wastes, and swimming pools. When used to treat potable water, chlorine helps alleviate the adverse effects of iron, manganese, ammonia, and sulfide. The Maximum Residual Disinfectant…
-
Protects water baths and other water systems against the growth of algae, bacteria, molds and biofilms. Just 2ml per liter of water adds a blue tint which will fade after about 3 months reminding you to change the water and add new conditioner. Protects pumps and thermostats and helps…
-
Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…
-
Chlorine Testing Dispenser
HF ScientificDPD Powder Pop® Dispenser with tests for Chlorine Compact and convenient Redesigned dispenser prevents clogging Dispense into round or square cuvettes Push button operation for precise dosing Portable dispensers accurately deliver the correct volume of DPD reagent for…
-
Color of Water Sets
LovibondA method for measuring the color of potable water in terms of an easily reproducible color standard is essential to water engineers responsible for the distribution of supplies for public consumption. Color determinations are useful for detecting any irregular contamination of the supply due…
-
Nitrite CHEMets Kit, Range: 0-2.5 ppm
CHEMetricsNitrite, an intermediate in the nitrogen cycle, is formed during the decomposition of organic matter but readily oxidizes to form nitrate. These processes occur in wastewater treatment plants, water distribution systems, and natural waters. Nitrites are useful as corrosion inhibitors,…
-
Chloride Titrets® Test Kits
CHEMetricsChloride is the most common inorganic anion found in water and wastewater. The Maximum Secondary Contaminant Level for drinking water for chloride is 250 mg/L. Natural sources of salt are the ocean and various salt deposits above and below ground. Chloride is very corrosive to most metals in…
-
Silica Vacu-vials® Kits
CHEMetricsSilica (SiO2) is the oxide of silicon, the second most abundant element in the earth's crust. Silica is present as silicates in most natural waters. Typical concentrations lie between 1 and 30 mg/L. Higher concentrations may exist in brackish waters and brines. The silica content of…
-
-
Lovibond® Tablet Reagent
LovibondThe DPD method is elementary for the determination of chlorine and for the correct dosing of the water care product. The DPD No.1 tablet is used to determine the free chlorine. The tablet is placed in a cuvette with a few drops of the water sample and crushed, sample water is added and mixed by…
-
Because of its strong oxidizing properties, chlorine is an excellent biocide used to treat potable waters, municipal wastes, and swimming pools. When used to treat potable water, chlorine helps alleviate the adverse effects of iron, manganese, ammonia, and sulfide. The Maximum Residual Disinfectant…
-
Method Dissolved carbon dioxide (CO2) is naturally present as a result of animal respiration, the decay of organic matter, and the decomposition of certain minerals. It is the major source of acidity in unpolluted water samples. Surface waters typically contain less than 10 ppm…
-
Alkalinity Test Kits
LaMotteDirect Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…
-
Method: colorimetric with test strips and reagents 10 - 25 - 50 - 100 - 250 mg/l Al MQuant™ UN Number: UN1814 Storage class: 8B Non-combustible, corrosive hazardous materials Storage: Store at +15°C to +25°C. Hazard: Corrosive Aluminium compounds are…
-
Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…
-
Method: colorimetric with test strips and reagents 0.02 - 0.05 - 0.1 - 0.2 - 0.5 mg/l As 0.1 - 0.5 - 1.0 - 1.7 - 3.0 mg/l As MQuant™ UN Number: UN3316 Storage class: 10 - 13 Other liquids and solids Storage: Store at +15°C to +25°C. Hazard: Irritant;…
-
COLORQ Alkalinity Reagent 60 ML
LaMotteReplacement LaMotte ColorQ Alkalinity Indicator reagent. This replacement reagent has a bottle size of 2 oz. This Reagent is for use with the Lamotte ColorQ Pro 7 Plus Test Kits.
-
-
-
-
Nitrite VACUettes Kit, Range: 0-300 ppm as N
CHEMetricsNitrite, an intermediate in the nitrogen cycle, is formed during the decomposition of organic matter but readily oxidies to form nitrate. These processes occur in wastewater treatment plants, water distribution systems, and natural waters. Nitrites are useful as corrosion inhibitors,…
-
-
Hydrogen peroxide is a strong oxidizing agent with a variety of uses. Applications include the treating of industrial effluents and domestic waste and serving as a disinfectant in aseptic packaging. The Ferric Thiocyanate Method Reference: D. F. Boltz and J. A. Howell, eds.,…
-
-
Spectroquant® COD Cell Test
MilliporeSigmaAll necessary reagents for the analysis are contained in the cells Considerate packaging design protects the cells from fluctuation even in unfavorable environment Elimination of possible mistakes through barcode-system