Sterilization Indicator Strips

Compare Tool

Select up to 3 products

Sterilization Indicator Strips
1 - 32 of 39
Sort
View
Show
  • sterilization cycles at 250°F (121°C) and 273°F (134°C). Twindicator® adds extra flexibility in sterilization monitoring: each 8” strip is perforated to allow for two 4” strips. The color change is easily observed on both 8” and 4” strips and indicates

  • OK® Sterilization Indicator Strips

    Propper Manufacturing

    sterilization conditions meet equirements, the arrow and the K will change to become at least as dark as the reference color O forming the OK expression. The color response pattern may be used for sterilizer diagnostic evaluation. The indicator dot printed on the distal end of the 8" strip

  • Gas-Chex® Sterilization Indicators

    Propper Manufacturing

    …Gas-Chex indicator strip features a special diamond-shape indicator that aids in sterile presentation. The "Gas-Chex" end of the strip should be placed in the portion of the package judged to be the most difficult for EO gas to penetrate. The end of the strip with the “diamond”…

  • Smalstrip Sterilization Indicator Strips are an economical alternative to OK strips and are designed for monitoring steam sterilization cycles at 250°F (121°C) and 273°F (134°C). It uses the same reactive ink as the OK strip. The correct endpoint is indicated when the…

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • Chex-All® Sterilization Pouches

    Propper Manufacturing

    …need to purchase separate indicator strips. Preprinted inside and outside indicators: For Steam and Ethylene Oxide gas In Steam: Yellow indicators change to gray-black (Red indicators do not change) In gas: Red indicators change to green (Yellow indicators do not change) Triple…

  • Chemical indicator strips, for use with steam sterilizers, require a temperature of 132 to 135°C (270 to 275°F). Daily verification ensures that items being processed have been run through a cycle, preventing the accidental use of items that have not been adequately processed.

  • …acetate a black preciptate, indicated by a visible black-colored reaction on the hydrogen sulfide paper strip. The lead acetate procedure is more sensitive than any other method for detecting hydrogen sulfide production. Packaging: Sterile filter paper strips (25 pcs, diameter 7 mm) impregnated…

  • …with ANSI/AAMI/ISO/EN 11138 series of standards and USP where applicable. Crosstex also offers Spore Strips, Mini Strips, Spore Wires, Spore Threads and Spore Coupons. Sterilization Applications: Steam Ethylene Oxide (EO) Dry Heat Hydrogen Peroxide/Plasma (VH 2 O 2 )

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • Strate-Line Sterilization Indicator Strips are an economical alternative to OK strips and are designed for monitoring steam sterilization cycles at 250°F (121°C) and 273°F (134°C). It uses the same reactive ink as the OK strip. The correct endpoint is indicated when the…

  • …of suspension. Diluent contains 20% ethanol. Allows for direct inoculation of products, typically to verify sterility of devices where a traditional biological indicator spore strip cannot be used. Can also be used for a variety of other microbiological tests including cleaning effectiveness…

  • For use in 100% EO and EO/HCFC gas mixtures. Long stripe of chemical indicator ink printed on perforated-style strip. Allows full- or half-length use in different pack sizes. Indicator changes color from red to green when exposed to ethylene oxide sterilization conditions.

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • Steam Sterilization Monitor Strips are used for evaluating sterilization process. These indicators which are specified by the U.S. military specification MIL-S- 36586 are GMP requirements of U.S. FDA. Appearance: Filter paper strip impregnated with spores of standard culture of…

  • …Chemical Indicator introduces innovations in indicator ink technology based on our advanced lead and heavy metal free ink formulation. Our new generation of indicators demonstrates exceptional performance which is customized for the most widely utilized steam cycles in hospital sterilization.

  • The only instant sealing sterilization pouches with steam and E.O. gas indicators inside and outside. Chex-All II pouches are great money savers because the need to purchase separate indicator strips is eliminated. Chex-All II pouches have indicator imprints on both the inside and outside.…

  • strips are certified for population, purity, and resistance (D-value, Z-value, survival and kill where applicable). Biological Indicator strips are compliant with ANSI/AAMI/ISO/ EN 11138 series of standards and USP where applicable. Applications: Ethylene Oxide or Dry Heat Sterilization

  • Autoclave Bags

    Bioscience International

    Indicator strip confirms sterilization Autoclavable to 160°C Indicator strip turns black after correct steam processing Suitable for sterilization of pathogenic material The bags have been developed to meet all various laboratory demands concerning capacity and…

  • Chex-All® Sterilization Tubes

    Propper Manufacturing

    …separate indicator strips in the tube is a cost saving. Preprinted inside and outside indicators: For steam and Ethylene Oxide gas In Steam: Yellow indicators change to gray-black (Red indicators do not change) In gas: Red indicators change to green (Yellow indicators do not change)…

  • Strips for use in monitoring sterilization processes. Mini Spore Strips consist of inoculated filter paper, 2 mm x 10 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The Mini Spore Strips

  • sterilization processing. Use of SCBIs reduces the possibility of contamination and minimizes the potential for false positives associated with post-exposure transfer. Reduced incubation time of 24 hours Visually distinct results Chemical Indicator on label provides instant indication

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • Strips for use in monitoring sterilization processes. Mini Spore Strips consist of inoculated filter paper, 2 mm x 10 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The Mini Spore Strips

  • …compliant with ANSI/AAMI/ISO/EN 11138 series of standards and USP where applicable. Crosstex also offers Spore Strips, Mini Strips, Spore Wires, Spore Threads and Spore Coupons. Sterilization Applications: Steam Ethylene Oxide (EO) Dry Heat Hydrogen Peroxide/Plasma (VH 2 O 2 )

  • …Spore Strips for use in monitoring sterilization processes. Spore Strips consist of inoculated filter paper, 6 mm x 30 mm, packaged in glassine peel pouches or envelopes. The glassine packaging provides protection from environmental contaminants during transport post exposure. The spore strips can…

  • …compliant with ANSI/AAMI/ISO/EN 11138 series of standards and USP where applicable. Crosstex also offers Spore Strips, Mini Strips, Spore Wires, Spore Threads and Spore Coupons. Sterilization Applications: Steam Ethylene Oxide (EO) Dry Heat Hydrogen Peroxide/Plasma (VH 2 O 2 )

  • …compliant with ANSI/AAMI/ISO/EN 11138 series of standards and USP where applicable. Crosstex also offers Spore Strips, Mini Strips, Spore Wires, Spore Threads and Spore Coupons. Sterilization Applications: Steam Ethylene Oxide (EO) Dry Heat Hydrogen Peroxide/Plasma (VH 2 O 2 )

  • …for use in monitoring Hydrogen Peroxide (VH2O2) sterilization processes. Spore Coupons are sterilized 316 steel coupons inoculated with spores at a specified population level with known resistance to vaporized hydrogen peroxide sterilization processes. Individually packaged in Tyvek®/Mylar…

  • …for use in monitoring Hydrogen Peroxide (VH2O2) sterilization processes. Spore Coupons are sterilized 316 steel coupons inoculated with spores at a specified population level with known resistance to vaporized hydrogen peroxide sterilization processes. Individually packaged in Tyvek®/Mylar…

  • …Biological Indicator Strips Duo-Spore® Biological Indicator Strips are prepared from suspensions of Geobacillus stearothermophilus and Bacillus atrophaeus and encased in a peel-open glassine pouch. The glassine pouch allows for exposure of the enclosed strip to the sterilant, without exposure…

Compare Tool

Select up to 3 products

Please Log In