Counting Chamber
-
Platelet Counting Chamber
Hausser ScientificSimilar to 5971R10 Chamber, but thinner, for platelet count using phase microscope and without concavity on the bottom
-
Mold Counting Chamber
Hausser ScientificFor counting molds in tomato products and mold mycelia in butter and cream, etc. Glass slide is of one piece construction 75 x 35 mm, has raised central section 15 x 20 mm which provides a cell of 0.1 mm depth when a cover glass is placed in position Two parallel lines 1.382 mm apart…
-
Petroff-Hausser Counting Chambers
Hausser Scientific…plateau. The Petroff-Hausser Counting Chamber is popular for bacteria and sperm counting. Usage: Sperm Analysis and Counting Bacteria Counting Cell-Depth: 0.02mm (1/50 mm) Ruling Pattern: Improved Neubauer, 1/400 square mm In order to count the number of sperm per…
-
Fuchs-Rosenthal Counting Chambers
Hausser Scientific…Counting Chamber is used for Cerebro-Spinal Fluid cell counts. (Cell-Depth 0.2mm) Directions for Use Usage: Cell Counts in Cerebro-Spinal Fluid Cell Depth: 0.2mm Volume: 0.2 Microliters Ruling Pattern: Fuchs-Rosenthal (Dark-Line) Diluting fluid for counting cells in…
-
Counting Chamber, Bright-Line, Reichert
Hausser Scientific…cut through the metalized surface of the counting area Ruling appears bright in contrast to fused-on, semitransparent metal layer V-shaped slit on the loading side of each counting area facilitates charging and minimizes overflow Chamber has concavity on the bottom, directly beneath…
-
Improved Neubauer Platelet Counting Chamber
Hausser ScientificSimilar to 5971C10 Chamber, but for platelet count using phase microscope Without concavity beneath the rulings. No. 1 1/2 cover glass, 22 x 30 mm, should be used. Cover glass not furnished, see Thomas number 1208Q35.
-
C-Slide Automated Cell Counting Chamber Slides
Electron Microscopy Sciences…Automated Cell Counting Chamber Slides For use with automated cell counters. Only compatible with the EVE and Countless Cell Counting machines. Features Quartz grade optical plastic Precise design leads to highly reproducible results Two counting chambers fitted with…
-
Packaging 1 counting chamber, complete with 2 haemacytometer cover glasses, in transparent plastic box. Legal Information BLAUBRAND is a registered trademark of BRAND GMBH + CO KG BRAND is a registered trademark of BRAND GMBH + CO KG
-
Legal Information BLAUBRAND is a registered trademark of Brand GmbH & Co. KG BRAND is a trademark of Brand GmbH & Co. KG
-
Counting Slide
labForce® (powered by Thomas Scientific)Consists of a shallow glass cell, 17.9 mm diameter x 0.4 deep, provided with two charging channels, 2 mm wide x 5 mm long For counting smaller plankters, use 43X dry objectives of approximately 0.65 n.a. and 4 mm e.f. See C.M. Palmer and T.E. Maloney. American Society of Limnology and…
-
Organoid Counting Software
Corning…– organoids per milliliter of solution and surface area data Fast – three-second analysis* utilizing cloud-based processing Cost-efficient and versatile – compatible with a standard 0.1 mm counting chambers and 0.2 mm counting chambers. No consumables required.
-
Petrifilm™ Lactic Acid Bacteria Count Plate
3M Food Safety…Bacteria Count Plate is a time-saving, sample-ready plate designed to determine total lactic acid bacteria populations in food and environmental samples. Self-contained anaerobic environment enabled by oxygen-scavenging technology and oxygen-barrier films. No gas packs, chambers, or CO2…
-
Propper Hemacytometer Cover Glass
Propper ManufacturingPropper Hemacytometer Cover Glass is for your red blood cell and platelet counting chambers.
-
Plastic Case
Hausser ScientificPlastic Case with foam insert for safe storage of Counting Chamber, cover slips, and pipettes.
-
Hemacytometer Cover Glass
Hausser ScientificCover Glass. For use with Double Neubauer Counting Chamber Set and BRIGHT-LINE* Hemacytometer Set. Dimensions: 20mm x 26mm x 0.4mm
-
Hemacytometer Cover Glass, pack of 6
Hausser ScientificCover Glass. For use with Double Neubauer Counting Chamber Set and BRIGHT-LINE* Hemacytometer Set. Dimensions: 20mm x 26mm x 0.4mm
-
Cellometer Plastic,1/2x3-Dual Pack 100 per cs
Bellco Glass…neubauer counting grid on plastic that is mounted onto a standard 25x75mm plastic slide. The dual counting chamber has a sample introduction port, counting grid and air evacuation port. This is deal for laboratories working with infectious samples. Duplicate samples may be counted or control/unknown…
-
Cellometer Plastic,1/2x3-Dual Dual-Pack 25 per cs
Bellco Glass…neubauer counting grid on plastic that is mounted onto a standard 25x75mm plastic slide. The dual counting chamber has a sample introduction port, counting grid and air evacuation port. This is deal for laboratories working with infectious samples. Duplicate samples may be counted or control/unknown…
-
…porous membrane. This chamber is suspended over a larger well which may contain medium and/or chemoattractants. Cells are placed inside the Chamber and allowed to migrate through the pores, to the other side of the membrane. Migratory cells are then stained and counted. Most migration assays utilize…
-
Bright-Line Reichert Hemacytometers
Hausser ScientificIn pocket-size polyethylene case with snap cover Includes 5971R10 Counting Chamber with two improved Neubauer rulings, two 0.4 mm cover glasses in removable polyethylene container and two Thomas diluting pipets, one for red and one for white cells.
-
Hausser Hy-Lite Kit
Hausser ScientificIncludes Thomas number 5971C10 Counting Chamber with double improved Neubauer ruling, two 20 x 26 mm cover glasses and two Thomas diluting pipets, one for red and one for white cells
-
Hemacytometer
LW Scientific…Neubauer rulings are 0.1mm below cover glass. The H-shaped moat offers two counting areas. Fused rhodium on glass provides distinct lines. High light transmission Brightly illuminated line Two special counting chamber cover glasses Light transmission between 29% and 32%
-
Millicell® Disposable Hemocytometer High-precision 2 channel
MilliporeSigma…chambers with two ports for sample injection. Count cells with the in the same way as you do with the Neubauer "improved" counting chamber. With this product you have a smaller risk of infection. There is no longer need for the cover slips and the following cleaning.The disposable counting chamber…
-
Corning® Cell Counter
Corning…accurate cell counts of “highly concentrated samples” (up to 1 x 10 7 cells/mL). Low Cost Like Manual Counting This Cell Counter works with the provided counting chamber or customer supplied hemocytometers, enabling users to enjoy the benefits of automated cell counting without…
-
…engineered individual counting chambers (100 mm depth) with integrated cover slip. The chamber has ports for sample loading. Neubauer Improved (NI) grid pattern is embedded in each chamber. Each grid pattern has nine large squares each measuring 1 x 1 mm and a total counting area of 3 x 3 mm.
-
Multiple Unit Counters With Totalizers
Denominator…bone marrow, chamber and other laboratory counts. Locking totalizers lock all counters after the first 100 total, automatically providing direct percentage readings at 100 counts. Inadvertant counting beyond 100 is prevented. A release button quickly unlocks the counter for the next 100 counts.
-
…cell counting in a Fuchs-Rosenthal (FR) chamber has been the gold standard for quantification of leukocytes in cerebrospinal fluid (CSF). An excellent correlation between cell counts obtained with the C-Chip chamber and FR chamber was observed. ("Determination of leukocyte counts in…
-
Sedgwick-Rafter Cell
Hausser ScientificAll-glass Whipple counting cell In accordance with APHA Standard Methods for the Examination of Water and Wastewater, 15th Ed. (1980) Method 1002F Cell, 50 mm x 20 mm x 1 mm deep, is formed by four matte-surfaced strips cemented to 76 x 34 mm slide Overall thickness 3.5 mm. With one…
-
Quick-Read 10 Chamber Slide
Globe Scientific…viewing chambers to accurately count cellular elements in urine sediment. The system is a combination slide and coverslip of optically clear acrylic with ten separate chambers, each holding a standard volume of 6.3uL. Ten processed and stained specimens can be read at a time. Each chamber contains…
-
…cell counting (bacterial, yeast, sperm) Blood analysis (Hematology): Blood cell counting Cell culture: Cell concentration measurement, Cell viability test Microbiology: Fungal spores counting Specifications: Outer Size: Width 25mm x Length 75mm x Thickness 1.6mm Chamber…
-
Rectangular Cover Glass
Hausser Scientific5972M10 cover glass is for use with double-ruled chambers. 5972M20 cover glass is for use with Speirs-Levy Eosinophil Chamber.
-
QuadCount™ Automated Cell Counter
Benchmark Scientific…consumable costs. Each chamber has a hydrophilic inner surface with an engraved grid pattern. High precision production and molding ensure that each QuadSlide™ meets the rigorous standards and dimensional tolerances required for optimal counting performance. 3 count modes available…