Restek, Gas Chromatography, Supplies
-
Securely holds up to 36 headspace vials (fits 6, 10, or 20 mL vials). Vials lock in rack for convenient one-handed cap removal. Openings in the bottom of each well facilitate drainage. Alphanumeric indexing on rack simplifies sample identification. Easy to clean and fully autoclavable.*…
-
2.0mL Sample Vial Racks
RestekRacks feature alphanumeric indexing for easier vial identification. Racks can be stacked for efficient storage. Fits most 2.0 mL, 12 x 32 mm vials (vials sold separately).
-
Indicating Oxygen Trap
RestekIndicator changes from light green to grey as oxygen is trapped Heavy-walled glass body, protected by polycarbonate sleeve, prevents oxygen and water infusion Prepurged for fast stabilization 100 psi (689 kPa) maximum operating pressure Reduces oxygen to 0.1 ppm 10 µm frits at…
-
Certificates enclosed with each kit Vials of clear or amber borosilicate glass with ID marking spots Closures with pre-inserted septa Each kit sealed for integrity
-
FID/NPD Adaptor Fitting
RestekEasy-to-use, sturdy, compact stainless steel fitting 1/16-inch nut uses standard graphite or Vespel/graphite ferrules Wrench pad won’t turn when installing a capillary column Includes 1/4- and 1/16-inch stainless steel nuts, and 1/4-inch Vespel and 0.4 mm ID graphite ferrules
-
Use same installation distance as manufacturer's adaptors Made of high-quality stainless steel Siltek-treated version available for additional inertness
-
These MXT connectors can be used with fused silica tubing because of a Valcon polyimide, 1/32-inch, one-piece fused silica adaptor. This unique graphite-reinforced composite allows a capillary column to slide into the adaptor and be locked in place simply by loosening and tightening the fitting. …
-
Reduces the release of hazardous materials from the capillary split vent into the lab Includes connecting lines and mounting kit
-
Never again will you burn your fingers removing a hot injection port liner. The Claw safely and cleanly removes liners, O-rings, or other small objects from the injection port. You can then place the hot objects in a clean 4 mL vial situated in The Claw holder until ready for reuse. Easily…
-
Thermolite Plus Septa
RestekUsable to 350 °C inlet temperature.* Ultra-low bleed minimizes background signal. New plasma coating eliminates sticking in the injection port. Precision molding ensures consistent, accurate fit. Septa have a CenterGuide design to minimize coring. (Not available on 6 mm, 7 mm, 8 mm,…
-
Pocket Magnifier
RestekSmall and easy to handle 10x magnification makes it easy to see the column end to verify a square cut
-
Tolerances closely controlled Can be removed from the septum nut weldment
-
-
Soap Film Bubble Flowmeter
Restek1mL flowmeter for flows between 0.1 and 10 cc/min 50mL flowmeter for flows between 10 and 300 cc/min Includes a reservoir bulb, twenty-four inches (60 cm) of 1/4-inch ID tubing, adaptor tubes for 1/8-inch tubing and 0.53 mm ID capillary columns, and Velcro fasteners
-
Includes twelve hex keys (Allen wrenches): 0.050", 1/16", 5/64", 3/32", 7/64", 1/8", 9/64", 5/32", 3/16", 7/32", 1/4", and 5/16".
-
Parker Nut & Ferrule Sets
RestekPlease note: Nuts and ferrules are not treated unless requested (custom parts). Nuts and ferrules normally are not in contact with sample pathway, and thus do not require coating.
-
Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind. The Restek ProFLOW 6000 is the only flowmeter you…
-
Includes the most common consumable GC supplies and tools. All parts meet or exceed performance of instrument manufacturer’s parts. Parts list makes reordering easy. Inlet kit includes: 0.4, 0.5, and 0.8 mm ID graphite ferrules Viton O-rings Capillary nuts Inlet…
-
All traps measure: 10 5/8" x 1 3/4" (27 x 4.4 cm)
-
Use for providing carrier, fuel, make-up, or auxiliary gases to laboratory instruments.
-
Hydrocarbon S-Trap
RestekRemoves hydrocarbons and other contaminants Reduces organics to 0.1 ppm (assuming 100 ppm input) Each individually activated to ensure maximum efficiency Fits in GC oven for easy thermal recharging Maximum operating pressure: 60 psi (414 kPa)
-
These electronic crimpers and decappers have a rechargeable 6.4-volt battery installed. The large battery allows for quick, powerful operation and a faster charge cycle, minimizing downtime. Charging the battery takes thirty minutes to two hours. The universal plug set includes U.S., European, UK,…
-
Restek Filter Base Plates
RestekEnd fittings available in brass or stainless steel Base plates fit all stand alone Super Clean gas filters offered Each single-position base plate unit measures: 4" x 4" x 1 7/8" (10.2 x 10.2 x 4.8 cm) Each 2-position base plate unit measures: 8" x 4" x 1 7/8"…
-
Tee Wrench
RestekHold 1/4" or 6 mm tee or cross fittings secure in multiple orientations during installation Fits easily in tool box, pouch, or belt Cushioned vinyl grip with generous gripping area For Swagelok fittings only
-
Includes heating coil and oven temperature sensor. Available in 120V and 220V units.
-
Deactivated Glass Wool
RestekMore inert than our traditional glass wool Use to vaporize a sample in a liner prior to introduction into a capillary column