Oxygen Trap
-
Oxygen Trap
PerkinElmerHigh efficiency oxygen trap has a capacity of 2.5 liters at room temperature. It is also effective for removing sulphur compounds such as hydrogen sulfide and mercaptans. This oxygen trap is for use with nonoxidizing gases such as; He, Ar, N2, and CH4. Oxygen removal to below 70 ppb using normal GC…
-
Oxygen Trap
SGE…will occur. These problems are created by hydrocarbons, moisture and oxygen in the carrier gases. Advanced Gas Filter System The Advanced Gas Filter System (AFS) has high capacity and efficiency levels for oxygen (750 cc, < 1 ppb), water (12 g, < 10 ppb) and hydrocarbons (8 g,…
-
Indicating Oxygen Trap
PerkinElmerIndicating oxygen trap with a capacity of 40 cc of pure oxygen and 100 psig maximum pressure, to be used downstream of a high capacity oxygen trap.
-
Indicating Oxygen Trap
Restek…changes from light green to grey as oxygen is trapped Heavy-walled glass body, protected by polycarbonate sleeve, prevents oxygen and water infusion Prepurged for fast stabilization 100 psi (689 kPa) maximum operating pressure Reduces oxygen to 0.1 ppm 10 µm frits at inlet…
-
High-Capacity Oxygen Trap
RestekRemoves up to 600 mg of oxygen or 2 g of water Long life—typically purifies more than five 200 ft 3 cylinders Reduces oxygen to 15 ppb Maximum operating pressure: 250 psi (1,724 kPa) Flow: 3 L/min @ 32 psi (221 kPa)
-
Economy Non-Indicating Oxygen Traps
Agilent TechnologiesAgilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.
-
Big Oxygen Traps
Agilent TechnologiesCapacity: 3 liters O2 or 3,200 mg Pressure: Up to 250 psig Efficiency: reduction of O2 to less than 1 ppb 750 cubic centimeter gas purifiers Ideal for bulk purification applications or where several instruments are plumbed from a single gas source One piece of heavy-walled aluminum…
-
Oxygen Removal Traps
Agilent Technologies…as saturation occurs. The Indicating Oxygen Trap (IOT) is designed for use in conjunction with high capacity, non-indicating oxygen traps. When properly installed downstream from the non-indicating trap, the IOT provides a visual indication of oxygen breakthrough before contamination reaches…
-
Oxygen Stainless Steel Trap
PerkinElmerSpring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
Click-On Traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2cm) Note: Replacement trap only—fittings sold separately.
-
Oxygen/Moisture Traps
Agilent Technologies…Agilent OT3 Trap contains a highly active, metal-containing, scrubbing material in an inert, aluminum body. This material removes 500 mL oxygen from a gas stream to less than 15 ppb. Additionally, up to 2 grams of moisture can be removed by this trap without affecting the oxygen capacity. …
-
Supelpure®-O Oxygen/Moisture Trap
MilliporeSigma…can reduce oxygen to less than 2 ppb when the level in the incoming gas does not exceed 10 ppm. Because the catalyst is coated on a Molecular Sieve, this trap also can remove water vapor.Dimensions: •120 cc Trap: 111/8in. (28.2 cm) long x 13/8 in. (35 mm) diameter •750 cc Trap: 161/2 in. (41.9…
-
Supelpure®-O Oxygen/Moisture Trap
MilliporeSigma…can reduce oxygen to less than 2 ppb when the level in the incoming gas does not exceed 10 ppm. Because the catalyst is coated on a Molecular Sieve, this trap also can remove water vapor.Dimensions: •120 cc Trap: 111/8in. (28.2 cm) long x 13/8 in. (35 mm) diameter •750 cc Trap: 161/2 in. (41.9…
-
Supelpure®-O Oxygen/Moisture Trap v
MilliporeSigma…can reduce oxygen to less than 2 ppb when the level in the incoming gas does not exceed 10 ppm. Because the catalyst is coated on a Molecular Sieve, this trap also can remove water vapor.Dimensions: •120 cc Trap: 111/8in. (28.2 cm) long x 13/8 in. (35 mm) diameter •750 cc Trap: 161/2 in. (41.9…
-
Oxygen/Moisture Combination Stainless Steel Trap
PerkinElmerSpring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
-
Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need…
-
Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in. There is no need for…
-
Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide (blue) in the moisture indicator. Available as a kit with the necessary 1/8" brass connectors, and…
-
Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need…
-
Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need…
-
Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
Supelpure® HC Hydrocarbon Trap
MilliporeSigma…traps are basically suitable in GC for carrier gas purification, as the name suggests they are primarily used for trapping hydrocarbons. Some hydrocarbon traps, like the Supelpure® HC Hydrocarbon Trap, contain a carbon molecular sieve that also restricts the elution of moisture and oxygen. Surges of…
-
Supelpure® HC Hydrocarbon Trap
MilliporeSigmaHydrocarbon traps are basically used in GC for carrier gas purification, as the name suggests they are primarily used for trapping hydrocarbons. Some hydrocarbon traps, like the Supelpure HC Hydrocarbon Trap, contain a carbon molecular sieve that also restricts the elution of moisture and oxygen.…
-
Indicating Moisture Trap
Restek…at 5% relative humidity Prepurged for fast stabilization Reduces noise from high-sensitivity detectors Heavy-walled glass body prevents oxygen and water infusion 10 µm frit prevents microparticulate damage to needle valves and flow controllers Maximum operating pressure: 100 psi…
-
Moisture Stainless Steel Trap
PerkinElmerClick-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in. There is no need for…
-
All traps measure: 10 5/8" x 1 3/4" (27 x 4.4 cm)
-
Glass Vacuum Cold Trap for Safe Vacuum Operations
Across International…cold trap not to condense liquid oxygen (a light blue liquid) into the cold trap. Liquid oxygen is potentially explosive, and this is especially true if the trap has been used to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap is…
-
Moisture Traps
SGE…will occur. These problems are created by hydrocarbons, moisture and oxygen in the carrier gases. Advanced Gas Filter System The Advanced Gas Filter System (AFS) has high capacity and efficiency levels for oxygen (750 cc, < 1 ppb), water (12 g, < 10 ppb) and hydrocarbons (8 g,…
-
Ultra Clean Oxygen Filter for GC and GC/MS
PerkinElmer…supply or system operation. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.
-
…results will occur. These problems are created by hydrocarbons, moisture and oxygen in the carrier gases. Advanced Gas Filter System The Advanced Gas Filter System (AFS) has high capacity and efficiency levels for oxygen (750 cc, < 1 ppb), water (12 g, < 10 ppb) and hydrocarbons (8 g, < 1…
