Cannon Instrument
-
Cannon-Fenske Series Viscometers
Cannon InstrumentCannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…
-
Bath Oil, 6-Gallon Container
Cannon InstrumentContains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.
-
High Viscosity Standards
Cannon InstrumentFor determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific
-
Flash Point Reference
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
CT-2000 Constant Temperature Bath
Cannon InstrumentMicroprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…
-
VISDISK for Windows
Cannon InstrumentPrograms are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…
-
-
SimpleVIS™ Portable Viscometer
Cannon InstrumentQuick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…
-
CT-1000 Constant Temperature Baths
Cannon InstrumentWide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…
-
TE-1500 Constant (Low) Temperature Bath
Cannon InstrumentDesigned specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
Viscometer Holder
Cannon InstrumentIncludes permanently attached round metal holder, for hole 51 mm (2 in) in diameter.
-
BS/U/M Miniature U-Tube
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…
-
Certified Viscosity “Check Oils” for SAE Target Viscosities
Cannon InstrumentCANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…
-
Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…
-
Large Vial
Cannon InstrumentThe Cannon Instrument large vial is an ideal accessory to have in any chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories.
-
High-Temperature Viscosity Standards
Cannon InstrumentFor use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…
-
BS/IP/RF U-Tube Reversed Flow Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…
-
Cold Cranking Simulator Viscosity Standards
Cannon InstrumentConform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles
-
TE-3000 Constant (Low) Temperature Bath
Cannon InstrumentFor glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F…
-
Flash Point Reference Materials
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
Cannon-Ubbelohde, CUU And CUC Series Viscometers
Cannon InstrumentUncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…
-
Pressure / Vacuum Pump, 120V, 60Hz
Cannon InstrumentInexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…
-
Viscosity Standard, -20 and -25°C for CMRV, 500 ml
Cannon InstrumentFor preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST
-
Viscometer Calibration Size 200
Cannon InstrumentSimilar to Cannon-Manning Vacuum (CMV, 9724-H50) series, but with graduated capillary instead of two timing bulbs. Provided with certificate of calibration and instruction sheet. Viscosity range, poise: 2400 - 52000 Approx. constant poise/second at 300mm Hg Bulb B: 128 Approx.…
-
Solid Rubber Micro Stopper
Cannon InstrumentTapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
CBC Bath Coolers
Cannon InstrumentThermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…
-
Kinematic Viscometers & Accessories
Cannon InstrumentThe Cannon Instrument probe is suitable for use with Dostmann dual channel digital thermometers for various viscometer models. You can choose ideal replacement part or accessory which ensures smooth functioning of thermometer units.
-
Paint Viscosity Standards
Cannon InstrumentFor Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.