Cannon Instrument
-
Paint Viscosity Standards
Cannon InstrumentFor Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…
-
Ink and Paint Viscosity Standards
Cannon InstrumentFor ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…
-
Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers
Cannon InstrumentCalibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ±0.2% Specifications conform with ASTM Standard D 446. Minimum sample…
-
BS/U/M Miniature U-Tube
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…
-
CT-500 And CT-518 Constant Temperature Baths
Cannon InstrumentCT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…
-
Flash Point Reference Materials
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
Modified Koppers Vacuum, Cannon Mkvc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…
-
Zeitfuchs Cross-Arm Calibrated Viscometers
Cannon InstrumentCannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…
-
Cold-Cranking Simulator Standards
Cannon InstrumentCANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).
-
Asphalt Institute Vacuum, Cannon Aivc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
BS/IP/RF U-Tube Reversed Flow Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…
-
-
SimpleVIS™ Portable Viscometer
Cannon InstrumentQuick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…
-
Cannon Four Bulb Shear Dilution Viscometers
Cannon InstrumentFour Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…
-
Semi-Micro, Cannon CUSMC Series Viscometer
Cannon InstrumentCalibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…
-
Cannon-Ubbelohde UBU And UBC Series
Cannon InstrumentUncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ±0.2% Similar to Cannon-Ubbelohde but less rugged in design.…
-
Viscometer Holder
Cannon InstrumentAll Cannon viscometer holders fit holes 51 mm (2 inches) in diameter. Rubber holders are made of neoprene rubber. Plastic holders are self-aligning and hold the viscometer firmly by means of a spring clip. Metal holders are also self aligning, and are constructed of chrome-plated machined brass.…
-
Pressure / Vacuum Pump, 120V, 60Hz
Cannon InstrumentInexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…
-
Vacuum Manifold
Cannon InstrumentWith three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…
-
Cold Cranking Simulator Viscosity Standards
Cannon InstrumentConform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles
-
TE-3000 Constant (Low) Temperature Bath
Cannon InstrumentFor glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F…
-
CT-600 Constant Temperature Bath
Cannon InstrumentIdeal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of…
-
BS/IP/SL(S) Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of…
-
Solid Rubber Micro Stopper
Cannon InstrumentTapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.
-
Cannon-Fenske Series Viscometers
Cannon InstrumentCannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…
-
High-Temperature Viscosity Standards
Cannon InstrumentFor use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…
-
Dual Channel Digital Thermometer
Cannon InstrumentThe Dostmann P795 dual channel digital thermometer is a precision hand held device for accurate temperature measurement. Dual channel technology allows simultaneous display of two readings or a differential result to meet the needs of automated viscosity applications, such as side-by-side kinematic…
-
Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt…