    CSC Scientific

    The Bostwick Consistometer is produced by CSC Scientific Company, Inc. It is a preferred instrument for checking production samples against consistency and flow rate standards. The Bostwick is a workhorse in Food Processing, Paint Manufacturing, Cosmetics Production and Chemical Operations.…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…

  • Calibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…

  • Easy-to-use, digital setting, compact design oil bath. Features BO400/410 Digital temperature setting by up and down arrow keys Removable oil tank for convenient cleaning and changing of oil Heater situated outside the water tank Exclusive connection for bath…

  • Removes all traces of oil Air pressure drives solvent No electrical contact needed Unit is designed to wash the inside of glass kinematic viscometer tubes with a jet of solvent. At the touch of a button, the solvent stream is cut off and an air jet is directed into the tubes for…

  • Made of polished stainless steel Looped handle and finger ring Calibrated with Cannon viscosity standards traceable to NIST; Cannon standards are produced in accordance with ISO 90002 Each cup is furnished with the mathematical formula for calculating the viscosity in centistokes…

  • DigiVac™

    Ideal for industrial and laboratory applications that require rough vacuum measurement. *Rugged design for harsh applications 316 stainless steel only wetted material in sensor. *Isolated and hermetically-sealed sensor to prevent contamination from system *Allows for recording and data capture…

  • Cannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…

  • Cannon Instrument

    Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…

  • Cannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…

  • Cannon Instrument

    All Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber.  Plastic holders hold the viscometer firmly with a spring clip.  Metal holders are constructed of chrome-plated machined brass.  A handle permits…

  • Inexpensive, compact source of low-level pressure and vacuum Fused circuit and grounded plug ensure safe operation Multiple fittings kit and polyurethane tubing are provided Oilless diaphragm pump operates quietly to produce a continuous pressure of 35 psi or an adjustable,…

  • IKA Works

    The T-spindle set is particularly suitable for the measurement of non-flowing samples, such as creams, pastes or gelatin. The set is the right accessory for electrica HELISTAND.

  • A&D Weighing

    Viscometer with revolutionary range & technology - Redefining standard viscosity determination. Advanced vibrating tuning fork technology works on a wide range of Newtonian Fluids. Provide fast accurate results and it is simple to use. Advanced benefits in difficult sample with low & high…

  • The IKA viscometer spindle is suitable for use in research facilities and chemical laboratories while conducting experiments. It is made of high quality material which ensures durability and long lasting usage. It is easy to handle and convenient to use.

  • IKA Works

    The Quick Connector enables the spindles to be connected directly to the ROTAVISC measuring System. Consisting of: 1x coupling to the ROTAVISC 6x adapter for the spindles

  • Quick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…

  • Cannon Instrument

    Contains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.

  • Microprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…

  • Cannon Instrument

    Programs are supplied on a 3.5” disk. The programs are designed to be user-friendly (they are accessed through a convenient menu system) and are provided with a detailed operator’s manual. The calculations performed include the following: Blending of oils- the W.A. Wright…

  • The bubble viscometers can be ordered individually to create a custom set. Economically priced Compliant with ASTM methods D1131, D1545, D1725

  • IKA Works

    Regardless of a simple or demanding viscosity measurement - IKA ROTAVISC HELI Complete determines the viscosity of medium viscous liquids in all areas of application ranging from the laboratory to quality control. Easy to operate The generous 4.3″ TFT display allows for an…

  • The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and…

  • IKA Works

    The standard spindle set SP set-1 includes four spindles (SP1, SP2, SP3, SP4). It is particularly suitable for viscosity determination in combination with the rotary viscometers ROTAVISC lo-vi Complete or ROTAVISC lo-vi Advanced. The standard spindle set SP set-2 includes six spindles (SP7, SP8,…

  • Wide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…

  • Four Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…

  • Large capacity 5L constant temperature water bath with internal diameter of f240 mm. Designed with flat-shaped bath with no heater or sensor inside for ease in cleaning. Temperature range: ambient +10~90°C. 100-115V. Large capacity 5L constant temperature water bath with internal diameter…

  • The consistometer is a bench top device used for accurately checking laboratory or production samples against consistency, viscosity or flow rate standards. While using little bench space, it provides a simple, accurate method of conducting a variety of flow associated tests. It can be used in…

  • Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…

  • Very small sample size: The SV-1A requires a sample volume of only 2ml (SV-10A: 10ml or more) so users do not waste any samples and can save costs. Titanium sensor plates: Anti-corrosive, titanium (JIS Class 2) sensor plates, which are resistant to chemical substances X-Y-Z stage: Fine…

  • Developed for a wide range of applications, ViscoQC 300 ensures the quality of your substance – from almost any fluid to semi-solid samples – by delivering fully traceable viscosity results with a Peltier device for the most precise sample temperature control – right at your…