Chemglass Stirrers

Compare Tool

Select up to 3 products

1 - 32 of 57
Sort
View
Show
  • Chemglass

    Precision ground and polished stirrer shaft for use with Chemglass process reactors. Designed to utilize CG-2095 and CG-2096 PTFE agitators. Lower portion of stirrer shaft is sandblasted and has a 3/8” wide flat.  Please Note: CG-2097-75 and CG-2097-100 are made from heavy wall tubing…

  • 10mm O.D. shaft is constructed using a molding process whereas the blade is molded directly onto the PTFE coated stainless steel shaft. This makes the stirrer chemically inert, easy to clean and can be used up to 280°C. The top of the shaft has 50mm of exposed 1/4" diameter stainless steel…

  • Shaft is precision ground and polished to fit our CG-2077-H, CG-2077-G and CG-2077-U style 10mm PTFE bearings. Designed to be used with cylindrical type reactors. The curved glass blades are spaced 120° apart and angled upward. PLEASE NOTE: STIRRER SHAFTS ARE DESIGNED FOR CLOCKWISE ROTATION.

  • Grease-Free PTFE stirrer bearing designed for use under moderate vacuum applications. The bearing consists of a threaded glass adapter having an inner joint, a set of PTFE washer style bearings, a stainless steel spring, nylon alignment ring and Celcon® compression cap. The unique design of…

  • Chemglass

    AGITATORS, PTFE, 5.5IN OD, 90°, 19MM SHAFTS Agitator made entirely of PTFE and glass filled PTFE, provides excellent stirring at the bottom of filter reactors, especially when heavy slurries are being mixed. Agitator attaches to stir shaft by both a compression fitting and a glass filled…

  • This incorporates a universal stirrer shaft coupling (CG-2046) to compensate for misalignment of drive motor and glass stirrer shaft. Nylon bushing compresses around shaft using an allen screw. Stainless steel stud and upper coupling attach directly to the motor shaft. For use with 30L…

  • Features: Compact overall Height Brushless DC motor Micro USB port for Control or Data Logging of RPM/Torque trends RS232 Communication Port Torque Compensation – Maintains set RPM with Viscosity Changes Precise Digital Closed Loop Speed Control: +/- 1.5 RPM CE Rated …

  • Grease-Free PTFE stirrer bearing designed for use under moderate vacuum applications. The bearing consists of a threaded glass adapter having an inner joint, a set of PTFE washer style bearings, a stainless steel spring, nylon alignment ring and Celcon® compression cap. The unique design of…

  • A 10mm precision ground stirrer shaft to fit CG-2070 through CG-2072 10mm bearings. Side button for attachment of CG-2080 or CG-2081 PTFE stirrer blades. PLEASE NOTE: THESE SHAFTS ARE NOT TO BE USED WITH ANY TYPE OF PTFE BEARING.  FOR POLISHED SHAFTS USED WITH PTFE BEARINGS SEE CG-2079.

  • Explosion proof (XP) motor features a 5:1 right angle gearbox to reduce the overall height above support frame to 10.5”. Motor is supplied with a 30ft 18/3 SJEOO cord with twist lock connector. XP motor must be used in conjunction with our digital motor controller, and mounts to all our…

  • 10mm O.D. shaft is constructed using a molding process whereas the blade is molded directly onto the PTFE coated stainless steel shaft. This makes the stirrer chemically inert, easy to clean and can be used up to 280°C. The top of the shaft has 50mm of exposed 1/4" diameter stainless steel…

  • Shaft is precision ground and polished to fit our CG-2086 19mm PTFE bearings. Designed to be used with cylindrical type reactors. The curved glass blades are spaced 120° apart and angled upward. PLEASE NOTE: STIRRER SHAFTS ARE DESIGNED FOR COUNTER-CLOCKWISE ROTATION. ALSO NOTE: 19MM…

  • This lightweight micro stirrer is ideal for use with tissue grinders having stainless steel pestles. Supplied complete with a stirrer/controller, tripod with a vertical support rod, clamp holder and a coupling to fit the 6.35mm diameter of the stainless steel pestle rod.

  • Cup is designed to catch all flaking that occurs with PTFE stirrer bearings. Made entirely of PTFE, the complete item consists of a compression fitting, deep perforated PTFE cup and a 50 micron porosity PTFE filter disc.

  • Agitators are made entirely of PTFE and glass filled PTFE and are for use with 19mm or 25.4mm OD stirrer shaft CG-2097 and are available in 45°, 60° and 90° impeller angles. The 45° and 60° impellers are set up to stir downwards in a clockwise direction and upwards when rotated…

  • Agitator blades are constructed of PTFE with a glass filled PTFE locking nut. This enables them to be attached to the shaft in any vertical position. Note: Designed for use with CG-2079-X, CG-2078-X or CG-2096-X PTFE Covered stainless steel type shafts

  • Beaded pipe to sanitary fitting adapter connects to the 1-1/2” beaded pipe side arm of CG-1968-GL zero dead space drain valve. Approximate overall length of adapter is 1.75”.  NOTE: Requires a CG-1968 beaded pipe coupling.

  • A 10mm precision ground and polished stirrer shaft for use with PTFE bearings and CG-2091 and CG-2092 PTFE agitators. Flat ground section extends half way up shaft and permits positive seating of the PTFE locking screws.

  • Agitators are made entirely of PTFE and glass filled PTFE and are for use with 10mm OD stirrer shaft CG-2075-B. Available in 45°, 60° and 90° impeller angles. The 45° and 60° impellers are set up to stir downwards in a clockwise direction and upwards when rotated…

  • Universal Stirrer Shaft Coupling incorporates a universal joint to compensate for misalignment of drive motor and glass stirrer shaft. Nylon bushing compresses around shaft using an allen screw. Steel stud attaches directly to the chuck of a stirrer motor. Supplied complete with an allen wrench. …

  • Heavy duty PTFE anchor made of 0.500” thick PTFE. Blade is shaped to mirror the contour of Chemglass cylindrical reactors. Designed for use with CG-2078 Chem-Stir® 10mm stirrer shaft. The blade is secured to the stirrer via a PTFE pin.  PLEASE NOTE: CG-2081-A-02 IS NOT…

  • Blade is shaped to resemble the contour of a round bottom flask. Blades are available solid or perforated. Made of 3/16" PTFE to fit 19mm OD stirrer shafts. Minimum joint size listed is the size required to allow passage of the blade.

  • FLAKE-FREE Chemically Resistant Maximum 500 RPM; Vacuum (~5 Torr) and Pressure (~3 PSI) Polymer Blend Sleeve Provides Excellent Wear Resistance For Use with Polished Glass, PTFE or Stainless Steel Stirrer Shafts Universal Chem-Vac™ PTFE stirrer bearing provides a VACUUM TIGHT…

  • Stirrer blade made of 3/16" thick solid PTFE for use with both Chem-Stir™ and button style stirring shafts having a 19mm OD.

  • High viscosity agitator, made entirely of PTFE and glass filled PTFE, provides excellent stirring at the bottom of 2L through 20L reactors, especially when heavy slurries are being mixed. Agitator attaches to stir shaft by both a compression fitting and a glass filled PTFE safety pin. Heavy…

  • Assembly consists of a 10mm OD Chem-Stir™ stirrer shaft, a precision bore-bearing having a standard taper inner joint and a PTFE blade. The blade is sized to fit the listed flask capacities.

  • Chemglass

    PTFE gasket is 0.015" thick with an opening to fit Chemglass stirrer shafts. Gasket is placed below the CG-2048 Safety collar to prevent wear as a result of the collar rotating against the stirrer bearing. Also useful as a dust cover.

  • Chemglass

    Grease-Free PTFE stirrer bearing for use under moderate vacuum. The bearing consists of a PTFE standard taper body, Nylon compression cap, PTFE Insert/bushing and a Nylon loosening nut. The PTFE insert/bushing provides only glass and PTFE contact with the reaction. Loosening nut above the standard…

  • Agitators are made entirely of PTFE and glass filled PTFE and are for use with 30mm OD stirrer shaft CG-2097 in 75 and 100L reactors. The 45°; angle impellers are set up to stir downwards in a clockwise direction and upwards when rotated counter-clockwise. The upper agitator hub is open so that…

  • Similar to CG-2070, but water jacketed to control bearing temperature. For use in moderate vacuum with a CG-2074 or CG-2075 ground 10mm stirrer shaft. NOTE: Not for use with CG-2078 or CG-2079 polished stirrer shafts.

  • Shaft is precision ground and polished to fit our CG-2076 and CG-2077 10mm PTFE bearings. Designed to be used with cylindrical type reactors. The curved glass blades are spaced 120° apart and angled upward.  PLEASE NOTE: STIRRER SHAFTS ARE DESIGNED FOR COUNTER-CLOCKWISE ROTATION.

  • Similar to CG-2070 but with a tooled lubricant cup at the top of the bearing to hold an increased amount of lubricant. NOTE: Not for use with CG-2078 or CG-2079 polished stirrer shafts.

Compare Tool

Select up to 3 products