PerkinElmer Lab Sampling Systems
-
Accuracy of large metal loops (1.0 mm, 0.040" bore) is about ±5%, intermediate loops (0.5 mm, 0.020" bore) ±10%, and small loops (0.2 mm, 0.007" bore) ±30%. Bore: 0.76 mm. Model 7725 Injector loops are not interchangeable with loops for the Model 7125. The port angle for the 7725 is 30° whereas the…
-
Length: 1 m, Inner Diameter: 0.6 mm, One Fitting
-
PEEK Sample Loops avoid many of the problems associated with stainless steel sample loops. Metal loops will often absorb sample components resulting in inaccurate quantitative results. In addition, metal loops may be corroded by high-salt buffers and chloride salts. Sample Loops are made from PEEK…
-
Fume Hood for SPB 50-72, 100-42
PerkinElmerThe fume hood can be connected to an in-house laboratory exhaust system or used with the SPB blower unit (N9308022). Fume hoods come flat packed to save transport costs and can be assembled in minutes without tools.
-
Polypropylene needs with 24 Positions
PerkinElmerPolypropylene or stainless steel needles minimize dead volume.
-
Foam Storage Rack, 100 mL
PerkinElmerThe foam storage rack is used to store up to 12 100 mL DigiTUBEs. Comes in packs of five.
-
PEEK Sample Loops avoid many of the problems associated with stainless steel sample loops. Metal loops will often absorb sample components resulting in inaccurate quantitative results. In addition, metal loops may be corroded by high-salt buffers and chloride salts. Sample Loops are made from PEEK…
-
Enough tubing and connectors are included for two replacements.
-
6.5 Stirrer for ASX-1400/1600
PerkinElmerStirring rod, 6.5 inches in length, for the ASX-1400 and ASX-1600.
-
The PerkinElmer Sample Tray for PerkinElmer AS-93 plus/S10 Autosampler with 60 locations for 15 mL solution containers.
-
SC Autosampler Probe PTFE 1.0mm ID
PerkinElmerA contoured design reduces carryover, while an all PFA wetted sample flow path reduces contamination. SC Autosampler Probe, Carbon fiber support, 1.0mm ID (gray marker), long probe, long capillary, connects to port #5 (¼-28 fitting) high flow.
-
Translucent polypropylene tubes, 13 mm x 100 mm, are designed to provide excellent chemical resistance.
-
-
The PerkinElmer Sample Tray for PerkinElmer AS-93 plus/S10 Autosampler (rinsing-port rack) with rinsing port location (location 0), 8 locations for 50 mL solution containers, and 29 locations for 15 mL solution containers.
-
SPB 100-30, 30 position 100 mL 115/230 V
PerkinElmerGraphite blocks are PTFE-coated to resist aggressive corrosive attack for guaranteed long life in harsh laboratory environments. Our sample blocks operate with either a SPB Digital Controller or SPB Touch Controller*. Please select a controller below and the appropriate Start Up Kit* which includes…
-
-
Vis/NIR (400 to 2400nm) 2 x 2m each.
-
60 mm Soda Glass Petri Dishes
PerkinElmerThe PerkinElmer 60 mm Soda Glass Petri Dishes are suitable for NIRA II 60 mm spinner. Includes pack of 10 Soda glass Petri dishes with lids.
-
Rack for SPB 15-108, 15 mL
PerkinElmerFor busy labs, additional acid resistant, polycarbonate Racks are available for all SPB systems. Exclusive RackLock feature locks DigiTUBEs in position within the rack allowing for easy, one-handed closure of screw cap.
-
Rectangular Long Path Cell Holder
PerkinElmerThe Rectangular Long-Path Cell Holder accepts cells with pathlengths from 10 to 100 mm. This optional cell holder is easy to install and has the same footprint as the Standard Cell Holder. It is designed for a precise fit and gives you maximum reproducibility.
-
Screw for Digestion Vessels with Direct Pressure Control (DPC) for High Pressure 100 mL (100 Bar) Digestion vessel for Titan MPS 8 Position Microwave Sample Preparation Systems.
-
Consists of stainless steel sampling probe and screw fitting (P/N B3000152), and flame capillary tubing assembly (P/N B3000157). Replaces P/N B0196963.
-
-
-
Includes ferrules and connector.
-
Non HF-Resistant Internal Standard Kit
PerkinElmerThis kit includes: EzyFit Glass Mixing T-piece N0777461 Internal Standard Sample Probe 0.25 mm ID N0777465 EzyFit Sample Tube - Twin N0777462 EzyFit Sample Tube 0.5 mm ID N0777463 EzyFit Internal Standard Tube 0.25 mm ID N0777464 Vitex ® Gripper Paper - Qty. 6 N0777848 Orange-Blue Flared…
-
Translucent polypropylene tubes, 17 mm x 100 mm, are designed to provide excellent chemical resistance.
-
PerkinElmer translucent polypropylene tubes are designed to provide excellent chemical resistance. PerformR ™ 15 mL and 50 mL conical tubes are designed for your routine everyday applications and storage needs. SuperClear ™ tubes are made from a unique medical grade resin. PerformR and SuperClear…
-
Cap for High Pressure 100 mL (100 Bar) Digestion vessels without DPC pressure sensor for Titan MPS 8 Position Microwave Sample Preparation Systems. Includes Vessel Cap made of TFM with pressure sensor for High Pressure 100 mL (100 Bar) Digestion Vessel.
-
-
KBr Powder for FTIR Sampling Kits, 100g
PerkinElmerThis kit contains samples to rapidly familiarize you with sampling techniques such as Transmission, ATR and Diffuse reflectance, and preparing a cast thin film. The kit also provides familiarization with IR software including Basic Operation, Quality Checks and Spectral processing (Search and…
-
Inner Diameter 1.0mm, Length: 1000mm, Color (screw fittings): Blue