Chromatography Sample Preparation
-
Diatomaceous earth is used as a filter aid to improve extraction efficiency of densely packed soils, such as clays. By mixing the sample with diatomaceous earth, recoveries can be improved and excess moisture can be absorbed. Packaged in a convenient 1 kg quantity. Improves extraction…
-
General Description For continuous "hands off" direct transfer of multiple liquid samples A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum…
-
1174R53 : Long-term storage of blank/sampled tubes. 1174R54 : Long-term storage caps. 1174R55 : Use for tightening long-term storage caps. 1174R57 : Assists with tube packing. 1174R58 : Use for connecting tubes in series. 1174R59 : Required for diffusive sampling with stainless…
-
Mini-Can Accessories
RestekThese accessories enhance mini-can usage and provide flexibility in their application, from personal, to area, to vapor intrusion sampling. Sampling Belt: Adjustable up to 50" Two reclosable hook-and-loop straps securely hold mini-can or other sampling device Straps slide…
-
Celite 545 Particle Size 0.02-0.1 mm
MilliporeSigmaCAS No.: 68855-54-9 pH: 10 (100 g/l, H2O, 20°C) Solubility: Bulk Density: 300 kg/m3
-
Gas Sampling Valves
RestekSulfinert treatment eliminates active sites in the valve or loop for better recovery of active compounds. Ideal for samples containing low concentrations of sulfur or other active compounds Sample loop sizes from 5 µL to 5mL
-
Resprep SPE Flow Filters
RestekDesigned specifically to improve flow when filtering oil and grease samples Use with Resprep Diskcover-47 reservoir, or any 47 mm glass sample reservoir
-
Cleaned, assembled, and ready to use Clear or amber glass Caps and PTFE-lined septa included
-
Use with 1, 3, or 6 L canisters for grab air sampling Variety of orifice sizes for fast sampling from 5 to 60 minutes Connect 1/4" compression fitting directly to canister valve inlet Replaceable frit protects orifice and valve from particulates Sample inlet design minimizes water…
-
Easy-VOC Grab Sampler
RestekPerfect for fast and simple grab sampling of small air volumes (50–500mL) directly into sorbent tubes* Easy, instant sample collection with no complicated pumps to calibrate or maintain Convenient to use anywhere, just attach a sorbent tube to the end of the handheld unit and draw a…
-
Extrelut Nt Refill Pack For Column Fillings Extrelut Nt 20
MilliporeSigmaCAS No.: 68855-54-9 pH: 10 (100 g/l, H2O, 20°C) Solubility: Bulk Density: 300 kg/m3
-
Hydrophobic (nonpolar) silica-based adsorbents; used to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water). All cartridges are manufactured using high density polypropylene and have polyethylene frits unless otherwise noted. Cartridges may be…
-
Free-flowing salts transfer easily and completely. Easy-open packets eliminate the need for a second empty tube for salt transfer. Convenient slim packets fit perfectly into tubes to prevent spills. Ready-to-use tubes, no glassware required. Pre-weighed, ultra-pure extraction salts. …
-
Accurately and precisely dispense liquids for QuEChERS extractions with this versatile pump. A quick, simple adjustment lets you set the output volume anywhere from 2.5 mL to 30 mL per stroke, and the included adaptors will accommodate most reagent bottles. Adjustment knob offers 56 output…
-
Resprep® vacuum manifolds for SPE sample preparation, filtration, and elution are available in 12- and 24-port configurations. These manifolds help in achieving consistent extraction and filtration results. Multiple sample processing with these manifolds simplifies procedures and saves time. The…
-
Single-stage, stainless steel Two pressure gauges and CGA-180 fitting Stainless steel diaphragm and Kel-F seat Accurate pressure control even at low flow rates Individually tested for leaks and impurities
-
Allows switching from pressure to vacuum in a matter of seconds. Quiet, oil-free unit will not contaminate the extraction system or your samples. Provides 20" Hg (68 kPa) vacuum or 18 psi (124 kPa) pressure. Not recommended for use with 24-port manifold. Warranty period is one year from…
-
Convenient, multiple adsorbent beds in a single cartridge For use in multiresidue pesticide analysis to remove matrix interferences Excellent for cleanup of dietary supplement extracts
-
SDVB Resin
RestekStyrene/divinylbenzene, equivalent to XAD-2 resin Untreated, packaged in 1 kg plastic containers Spherical, 20 to 60 mesh particles
-
High-quality thermal desorption tubes are suitable for ppt to ppm concentrations of volatile organic compounds (VOCs) in ambient, indoor, personal, and industrial hygiene environments. Fit Markes (ULTRA and UNITY), PerkinElmer, and Shimadzu thermal desorbers. Packed tubes come with a report…
-
7 µm In-Line Filters
RestekThis 316 stainless steel filter is designed to collect particles larger than 7 microns. We offer Siltek-treated and stainless steel versions (1/4" compression fitting on both ends). Note: frit is not replaceable.
-
Optimized for Methods TO-14A, TO-15, IP-1A, ASTM D5466, OSHA PV 2120, and NJ DEP Low Level TO-15 Proprietary electropolished surface maintains compound stability. High-quality, metal-to-metal seal, 2/3-turn valve with stainless steel diaphragms prevent sample adsorption for more-accurate…
-
47 mm glass fiber disks embedded with specialty bonded silica Meet requirements for EPA Method 1664.* Reduce emulsion formation and amount of solvent required by previous EPA methods No chlorofluorocarbons needed *A sodium sulfate drying tube (cat.# 26207) and a 0.45 µm PTFE…
-
Small Cylinder Stand
RestekThis cylinder stand is designed to support small-diameter cylinders, such as 104L and 110L disposable cylinders. It is a simple, safe, and economical way to stabilize the position of small cylinders, while keeping them within close proximity. The stand is constructed of heavyweight painted steel…
-
Diskcover-47 Reservoir
RestekThe Diskcover-47 open-top reservoir allows you to pour up to 125 mL of sample directly onto the filter disk holder. It easily installs on top of the Diskcover-47 extraction disk holder. *Must be used with the Diskcover-47 extraction disk holder.
-
Metering Control Valves
RestekReduces pressure between sample cylinder and GC injector Maintains fine metering control Contains Kel-F seat
-
Swagelok sample cylinders are made of 304L and 316L stainless steel to resist corrosion and DOT rated to 1,800 and 5,000 psig (TPED cylinders rated to 1,450 and 4,350 psig), which allows sampling at gas wellheads as well as on-site refineries. Each cylinder is hydrostatically tested to at least 5/3…
-
This unique grab sampler is specifically designed for soil gas sampling by allowing the connection of tubing coming from the soil gas sample port. The innovative design minimizes connections and leaks and houses a critical orifice in the tee fitting. It also incorporates a vacuum gauge and 2…
-
Chemker Vacuum Pumps
RestekPTFE wetted parts are highly resistant to corrosive gases Diaphragm-based pump is low maintenance and virtually pollution free Quiet, low-vibration units keep disturbances to a minimum Built-in thermal protector automatically shuts off pump if it overheats and then restarts it once the…
-
Canister Air Sampling Timer
RestekThese timers are designed to simplify both automated and manual air sampling. The easy-to-use keypad and graphic display facilitate the programming of up to 12 timed events. They offer the convenience of remote start/stop sampling and permit intermittent sampling throughout a test period. The LCD…
-
Use the CGA-160 inlet connection with 14L Scott/Air Liquide transportable gases. Use the CGA-165 inlet connection with 48L Scott/Air Liquide transportable gases.