BioAssay Systems Chemicals Assay Kits

Compare Tool

Select up to 3 products

HomeAll Products

BioAssay Systems Chemicals Assay Kits

1 - 32 of 181
Sort
View
Show
  • For quantitative determination of albumin. Use as little as 5 μL samples. Detection range 0.01 - 5 g/dL (1.5 - 750 μM) albumin in 96-well plate assay. Can be readily automated to assay thousands of samples per day. Method: OD620 nm (BCG). Samples: Serum, plasma, urine,…

  • For quantitative determination of reduced and oxidized glutathione (GSH/GSSG). Linear detection range 0.01-3 µM GSH equivalents. Method: OD412nm. Samples: Whole blood, plasma, serum, urine, tissue and cell extracts.

  • For quantitative determination of total antioxidant capacity (TAC) and evaluation of drug effects on TAC metabolism. Linear detection range from 1.5 to 1000 μM Trolox. The procedure involves addition of a single working reagent and incubation for 10 min. Can readily automated to…

  • BioAssay Systems

    Deionized water used for preparation of samples for use with the QuantiQuik™ UreaQuick Test Strips .

  • For quantitative determination of phosphate and evaluation of drug effects on phosphate metabolism. Linear detection range 0.3 - 50 μM (0.0028 - 0.47 mg/dL) phosphate in 96-well plate assay. Can readily automated for processing thousands of samples per day. Method: OD620 nm. …

  • For quantitative determination of zinc ion Zn2+ and evaluation of drug effects on zinc metabolism. Linear detection range 0.12 -10 μM (0.78 - 65 μg/dL) zinc in 96-well assay format. Can be readily automated to process thousands of samples per day. Method: OD425 nm. Samples:…

  • β-N-Acetylglucosaminidase activity determination in biological samples. Linear detection range 0.2 - 50 U/L β-N-acetylglucosaminidase. Homogeneous "mix-incubate-measure" type assay Can be readily automated to process thousands of samples per day. Method: OD405 nm.…

  • For quantitative determination of succinate (succinic acid) in food, beverage, agricultural products, and other biological samples. Linear detection range 10 - 400 µM for colorimetric assays and 2 - 40 µM for fluorimetric assays. Convenient room temperature assay. No 37°C…

  • For quantitative determination of glucose oxidase activity and evaluation of drug effects on its metabolism. Linear detection range 0.02 to 10 U/L glucose oxidase for colorimetric assays and 0.002 to 1.5 U/L for fluorimetric assays. Homogeneous high-throughput assay. Method: OD570 nm,…

  • For quantitative determination of lipase activity. Linear detection range 40 to 1600 U/L lipase activity in 96-well plate assay. Can be automated to process thousands of samples per day. Method: OD412nm. Samples: Serum, plasma, saliva, urine etc.

  • BioAssay Systems

    Sodium Orthovanadate is a general inhibitor for protein phosphotyrosyl phosphatases. BioAssay Systems vanadate reagent is activated for maximum inhibition. Uses: to preserve protein phosphorylation state in cells and lysates. Ready-to-use phosphatase inhibitor. Fully activated for maximum…

  • Direct determination of formate concentrations in biological (e.g. urine, blood, etc.) and other samples. Linear detection range 0.050 to 5 mM Formate. Convenient room temperature assay. No 37°C heater is needed. "Add-mix-read" type high-throughput assay. Method: OD565…

  • BioAssay Systems

    For quantitative determination of DNA. Linear detection range 2 - 40 ng (100 - 2,000 ng/mL) calf thymus DNA in 96-well plate assay. Convenient. Single working reagent. Can readily automated to test tens of thousands of samples per day. Low interference. RNA, salt (up to 3M NaCl),…

  • For quantitative determination of reduced glutathione (GSH) and evaluation of drug effects on glutathione metabolism. Linear detection range 0.4 - 100 μM in 96-well plate. Low interference. Amino acids and common buffers do not interfere. Method: OD412nm. Samples: Whole blood,…

  • Acetaldehyde determination in biological and food/beverage samples. Fast and sensitive. Linear detection range (50µL sample): 0.5 µM to 60 µM acetaldehyde in 96-well plate assay. The procedure involves adding a single working reagent, and reading the absorbance after 30…

  • For quantitative determination of hemoglobin and evaluation of drug effects on hemoglobin metabolism. Safe. Reagents are non-toxic. Linear detection range 0.9 - 200 mg /dL hemoglobin. The "mix-and-read" 5 minute procedure. Can be readily automated to process tens of…

  • For quantitative determination of hemoglobin (Hb) in whole blood. Safe. No hazardous chemicals (e.g. potassium cyanide in Drabkin’s Reagent) used. The "mix-and-read" procedure involves addition of a single reagent and reading the optical density. Can be readily automated…

  • BioAssay Systems

    For quantitative determination of phosphatase activity The detection limit is generally 3 ng phosphatase or below. No wash or reagent transfer steps are involved. All reagents are compatible with high-throughput liquid handling instruments. Method: OD405 nm. Samples: Protein phosphatases.

  • For sensitive and high-throughput phosphate determination. Very stable reagent. High sensitivity and wide detection range (0.02 - 40 μM phosphate). Homogeneous "mix-and-measure" type high-throughput assay. Assays can be performed in tubes, cuvettes or microplates. …

  • For rapid quantitative determination of cytotoxicity based on lactate dehydrogenase released into cell culture medium. Evaluation of toxic compounds, toxins, detergents, environmental pollutants and physical treatment on cell lysis. Safe. Non-radioactive assay (cf. chromium release assay) …

  • For quantitative determination of glyoxalase activity. Note: use a UV plate (e.g. 96-well UV plate, cat# P96UV). Fast and sensitive. Detection Limit 4 U/L GLO-1 Activity. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on…

  • Homogeneous assay for cell viability, proliferation, cytotoxcity and evaluation of anticancer agents Safe. Non-radioactive assay (cf. 3H-thymidine incorporation assay) Sensitive and accurate. As low as 950 cells can be accurately quantified Fast. High-throughput assay using 96-well…

  • For quantitative determination of β-glucosidase activity and evaluation of drug effects on its metabolism. High sensitivity and wide linear range. Use 20 μL sample. The detection limit is 2 U/L, linear up to 250 U/L. Homogeneous and simple procedure. Simple…

  • For quantitative determination of urinary protein and creatinine concentrations (protein/creatinine ratio, UPCR). Linear detection range 1 - 20 mg/dL Protein and 1 – 150 mg/dL Creatinine. Fast and convenient. No sample pre-treatment is needed. Simple "Mix-incubate-read"…

  • Free Amino Nitrogen determination in foods and beverages (e.g. beer, wort, wine, must, etc.) Fast and sensitive. Linear detection range (5 µL sample): 0.2 to 10 mM for 10 min reaction. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be…

  • For quantitative bioluminescent assay for ADP:ATP ratio (apoptosis) in cells. Safe. Non-radioactive assay. Homogeneous and convenient "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: Luminescence. Samples: Cells.

  • MPO peroxidation activity determination in biological samples (e.g. cell lysates, tissues, etc.) Linear detection range 0.0025 to 2 U/L. Homogeneous "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: FL530/585 nm. …

  • For quantitative determination of glucose and evaluation of drug effects on glucose metabolism. Linear detection range 5 to 300 μM (90 μg/dL to 5.4 mg/dL) glucose for colorimetric assays and 1 to 30 μM for fluorimetric assays. Method: OD570 nm, or FL530/585 nm. Samples: Serum,…

  • For quantitative determination of alanine transaminase activity. Linear detection range 2-100 U/L. Assay can be carried out in a microplate or a cuvette and takes only 10 min. Method: OD340 nm. Samples: Serum, plasma etc.

  • For quantitative determination of aspartate transaminase (AST) activity and evaluation of drug effects on AST activity. Linear detection range 2-100 U/L. Assay can be carried out in a microplate or a cuvette and takes only 10 min. Method: OD340 nm. Samples: Serum, plasma etc.

  • For quantitative determination of phospholipase D activity and evaluation of drug effects on phospholipase D metabolism. Detection range colorimetric assay 0.06 - 10 U/L, fluorimetric assay 0.04 - 1 U/L. Can be readily adapted to high-throughput assays for drug screening. Method: OD570…

  • For quantitative determination of pyruvate and evaluation of drug effects on its metabolism. Linear detection range 2 - 500 μM pyruvate for colorimetric assays and 0.2 - 50 μM for fluorimetric assays. Convenient room temperature, high-throughput assay. Method: OD570 nm, or…

Compare Tool

Select up to 3 products