Air Samplers

Air samplers are ideal for various lab purposes, including collecting air samples for specific purposes, including environmental monitoring, microbial analysis, and contamination assessment.
The air sampling process is essential for detecting air contaminants such as gases, vapors, dust, and fibers.
Thomas Scientific offers extensive air sampling equipment, including air sampling canisters, air sampler tubes, and microbial air samplers. All equipment is suitable for both static air sampling and personal air sampling.
Volumetric air samples are suitable for environmental monitoring and occupational health applications. They’re also appropriate for collecting airborne particles, microorganisms, gases, and other compounds.
Air sampler tubes are used to collect and analyze gaseous contaminants of compounds in the air and can assist with achieving clear and accurate results. When selecting air samplers, consider the volume, particle size, and ease of use within the laboratory environment for a safe and convenient application.

Compare Tool

Select up to 3 products

HomeAll Products

Air Air Samplers

33 - 64 of 70
Sort
View
Show
  • Accessories for MD8 air sampling devices

  • Ace Glass

    All-glass check valve with ground seat and precision ground solid ball. Suitable with mercury in the vertical position, more sensitive to other fluids in the horizontal position. Connections are 8mm O.D.

  • A rapid, efficient and foolproof Purge Valve for 100% replacement of air in reaction vessels with any desired gas (N2, H2, Ar, Cl2, etc.). No mercury used, no reducing valve needed on gas source, no high vacuum source necessary. No need to watch manometers, hand control gas flow, or install warning…

  • Graduated Schlenk storage tube with 14/20 or 24/25 outer top joints, 14/35 or 24/40 inner joint side arms, stopcock inlet or hose barbed inlet valve. Reaction accessories include 7759 series filter tubes, 7807 series finger condenser, 9543 series stoppers and 13657-33 stirring magnet..

  • Filters Breakthrough Indicators Inline for Acids, Ammonia, Ammonia & Hydrogen Sulfide, Basic Vapors, Formaldehyde, Humidity, Hydrazine, Hydrogen Sulfide and Mercury. The BTI Inline is colorimetric indicator that indicate the saturation and exhaustion of carbon adsorbers and filters.The BTI…

  • Carbon adsorbers and Filters Change Indicators for Ammonia, Ammonia & Hydrogen Sulfide, Hydrazine and Hydrogen Sulfide. The breakthrough (saturation) indicators are colorimetric indicators that indicate the saturation and exhaustion of carbon adsorbers and filters. The indicators are…

  • Carbon Adsorbers and Filters Change Indicators for Ammonia, Ammonia & Hydrogen Sulfide, Hydrazine and Hydrogen Sulfide. The breakthrough (saturation) indicators are colorimetric indicators that indicate the saturation and exhaustion of carbon adsorbers and filters. The indicators are…

  • A high velocity impinger (Ref. AGI-30) which passes 12.0 to 13.0L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • The SAS Super 100 & 180 microbial air samplers are the top choices of the world's leading pharmaceutical and food companies, as well as numerous governments around the world for detection of microbial contamination and air quality testing. Featuring a powerful, high volume air flow of…

  • Collection bottle, usually connected to the bottom arm of the 7495 tee with reduced ends, to collect heavy particulates before they enter the manifold train.

  • Carbon Adsorbers and Filters Change Indicators for Acids, Ammonia, Ammonia & Hydrogen Sulfide, Aromatic Diisocyanates, Basic Vapors, Halogens, Hydrazine, Formaldehyde, Hydrogen Sulfide and Mercury. The breakthrough (saturation) indicators are colorimetric indicators that indicate the…

  • The HPLC Solvents Breakthrough Indicator is qualitative (yes/no) colorimetric indicator of the end-of-service life of low-flow filters. It is designed to provide real-time indication of the saturation and breakthrough of hplc solvents. HPLC solvents include Acetone, Acetonitrile, Chloroform,…

  • With completely adjustable 7mm inner tube. Tube has a pulled tip and is secured by a #7 Ace- Thred. Volume approximately 40mL. Tapered bottom of vessel allows for use with small volumes. Nylon bushing supplied with FETFE O-Ring. Available modified with #7 Ace-Threds on inlet/outlet for use with…

  • Filter support assembly for collecting dust particles in a stack sampling system. Available in either 51mm (2"), 76mm (3") or 102mm (4") (illustrated) size. Consists of: PART A, with 28/15 outer joint bent perpendicular to flow path; PART B, with seat for fritted disc and 28/15 inner…

  • Single tube vacuum manifold with #15 o-ring joint ends. Available with 3 or 4 high vacuum stopcock ports. Order with inner joint port ends (14/20 or 24/40) or #15 o-ring joints. The distance between ports is 95mm, ideal for flasks up to 250mL. Please see our various o-ring joint adapters such as…

  • Vacuum/gas manifold with a Firestone Rapid Purge Valve at one end and 0-5mm High Vacuum, Easy Action PTFE Stopcock ports with 3/8" 0.D. Swagelok tubing connections. Each connection has an O-Ring groove (O-Rings supplied) for use with #11 Ace-Thred. Valve eliminates the need for a second tube.…

  • Vacuum, NO-AIR adapter for vacuum cart, vacuum manifolds and Schlenk lines. Has No. 15 O-Ring joint side port with a Hi-Vac valve for precise flow control and an ACE-THRED bottom outlet.

  • Real-time filter breakthrough indicators. You don't have to change your filter in 3 months, 6 months or 9 months, change your filter only when exhausted and saturated using real-time breakthrough indicators. Get the most use of your filters and protect yourself from exposure to toxic chemicals.…

  • Ace Glass

    With 14/20 or 19/22 joints, outer joint at top and inner at bottom. Size B hose connection is on side.

  • Dräger

    DrägerTubes® are glass vials filled with a chemical reagent that reacts to a specific chemical or family of chemicals. A calibrated 100mL sample of air is drawn through the tube with the Dräger accuro® bellows pump. If the targeted chemical(s) is present the reagent in the…

  • Ace Glass

    Glass Manifold with #15 Ace-Thred at either end To allow switching 5853 vacuum connection to left or right side. Supplied with three or five, 4mm straight bore PTFE stopcock sampling ports. (Additional ports can be ordered.) Overall length of glass manifold is 230mm. Complete item consists of 8763…

  • Vacuum adapter with 2mm bore stopcock on side arm.

  • Adjustable bleed adapter used for reducing air flow in the Air Sampling Manifold to prevent a pressure drop across the sampling ports. Normally installed in front of the 7511 blower, in line with the manifold. Positioning of holes in threaded nylon plug controls the volume of air flow. Plug…

  • Ace Glass

    Aluminum blower mount for connecting 7511 blower to glass manifold. With threaded stock.

  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Imhoff sedimentation cone for the determination of settleable matter in water. Either blunt tip or Ace-Thred tip for environmental applications. Graduated from 0-2ml in 0.1ml divisions, 2-10ml in 0.5ml divisions, 10-40ml in 1ml divisions, 40-100ml in 2ml divisions.

  • Ace Glass

    Sampling tee with top threaded, side and bottom tubes reduced for use with 7506 bushing.

  • Single tube vacuum manifold with 35/20 ball joint ends. Available with 3 or 4 high vacuum stopcock ports. Order with inner joint port ends (14/20 or 24/40) or #15 o-ring joints. The distance between the ports is 95mm, ideal for flasks up to 250mL. Please see our various o-ring joint adapters such…

  • Permanent split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v…

  • The TRIO.BAS™ instruments utilize the impaction method of air sampling. The air, passing through an aspirating head, impacts onto an appropriate agar plate that collects bacteria or other organic substances possibly present in the sampled area. All of our air samplers are lightweight,…

  • Thomas No. 1165A11 14/20 vacuum adapter, 30mm stem below the joint. Thomas No. 1165A12 14/20 vacuum adapter, 175mm stem below the joint. Thomas No. 1165A13 19/22 vacuum adapter, 30mm stem below the joint.

  • Ace Glass

    An all-glass check valve with ground seat for liquid seal. Available in style A for vertical use, and style B for right angle connection. Connections are 8mm O.D.