Vacuum & Gas Manifolds
Explore our selection, which includes double vacuum manifolds, double vacuum/inert gas manifolds, air sampling manifolds, vacuum manifold accessories, gas manifolds, and drying assemblies. These advanced systems ensure seamless operations, allowing you to easily manage vacuum and gas processes.
In this category, you'll find trusted brands such as SP Wildmad-LabGlass, Kemtech America, Ace Glass, Chemglass, Advantec MFS, and Sartorius, each renowned for their quality and innovation.
Experience the manifold benefits of our vacuum & gas manifolds, including enhanced laboratory efficiency and seamless vacuum and gas handling. Whether you need a Schlenk manifold, a vacuum manifold, or a gas manifold, our collection offers the highest precision and flexibility for your lab's operations.
Elevate your lab's vacuum and gas handling capabilities with our products, which provide a reliable performance for your scientific endeavors.
-
Microsart 1, 2, 3, & 6-branch manifold for Microsart filtration units and funnels Equipment for the filtration of liquid samples in the microbiological quality control by vacuum; with Microsart base support for the use of Microsart Funnels or Microsart@filter, with venting filter and…
-
Stainless Steel Vacuum Manifold
Advantec MFS1-place, 3-place, or 6-place Standard cup accepts No.8 or 8b stopper Choice of 2- or 3- way valves Vacuum manifolds allow filtration of multiple samples either at once or independently by controling the separate branch valves. The durable type 304 stainless steel can be used for…
-
SYNTHWARE Vacuum Manifolds, High Vacuum Valves
Kemtech AmericaWith a serrated hose connection (10mm O.D.) at left or right hand side. Main tube is 22mm O.D. and the distance between valves is 100mm center to center.
-
Microfil Filtration System
MilliporeSigmaMicrofil® system uses presterilized, ready-to-use funnels and mem/lianes on a patented filtration support, cost-effective. Convenient, easy to use system for well-accepted mem/liane filtration method conforms to international standards: CEN, Standard Methods, WHO Disposable,…
-
Gas Manifolds, 4-Place, Glass Stopcocks
ChemglassFour port manifold with 2mm bore glass stopcocks on the ports. A "T"-bore stopcock is located 100mm from the end of the manifold and 40mm from the first port. The distance between the other 3 ports is 50mm with the last port being 75mm from the opposite end of the manifold. The entire…
-
Sterility Test Manifold and Holders
MilliporeSigma3- and 6-place manifolds for sterility testing Stainless steel body, valves and filter supports
-
Walters Manifold
Ace GlassHign vacuum manifold systems feature Easy Action PTFE stopcock valves providing for greaseless operation. Double-tube codes -50 & -54 feature Ace-Threds and 8mm OD tube-end ports. Double tube code -52 features hose barbed connections and 45 degree port placement. Walters manifold, code -40,…
-
Line has 5-ports with 4mm solid double oblique high vacuum stopcocks, CG-468-02, having a constant pressure retaining device, and 24/40 inner joints with hooks just above the grind. Ports are spaced 150mm center to center and have rod bracing to vacuum bank. Large ID of vacuum bank (40mm) provides…
-
SYNTHWARE High Vacuum Manifolds, Solid Glass Stopcocks
Kemtech AmericaWith 4mm double oblique, high vacuum solid glass stopcocks precision ground with corresponding numbers on barrel and plug. Solid glass stopcocks have constant pressure retention devices. Distance between stopcocks is 75mm center to center.
-
Single bank vacuum manifold with 0-8mm Chem-Vac™ Chem-Cap® valves mounted on a 45° angle to the user permitting easy operation inside of a fume hood. Ports are spaced 75mm center to center. All connection ports are #15 o-ring connections that incorporate a greasefree o-ring seal.…
-
Microsart 1, 3 & 6-branch manifold with 100ml Stainless Steel Funnel Equipment for the filtration of liquid samples in the microbiological quality control by vacuum; with base support for 47 and 50mm filter and 100ml stainless steel funnel, with silicone tubing pack size 1
-
Air Sampling Manifold
Ace GlassStraight sampling manifold, available with one end threaded, the other end reduced for use with 7506 bushing, or both ends threaded for use with either 7506 bushing or 5841 coupling. Also available with adjustable depth, threaded sampling ports for use with up to 7mm O.D. tube. Code identifies I.D.…
-
Carb Octopus Air Sampling Manifold
Ace GlassThe vertically mounted Carb Octopus air sampling manifold design features an inner tube which allows condensation to drip to the collection bottle and away from the #7 Ace-Thred instrument ports. Available in standard 4 or 8 port configurations.
-
Stainless Steel Vacuum Manifold
Thermo Scientific NalgeneNalgene 345 Solid and stable on the bench top Designed with three vacuum outlets, each with leakproof, two-way valve and vent port Each outlet securely holds a No. 8 stopper and the stem filter funnel without interference Autoclavable Easy manipulation of individual funnels…
-
SYNTHWARE Manifold with #15 O-Ring Joints
Kemtech AmericaWith 4mm double hollow high vacuum stopcocks. This four–port manifold is fitted with two 14/20 and 24/40 inner joints, and is 100mm center to center joints.#15 O-ring joint stopper (S480015) and #15 O-ring joint to serrated hose adapter have to be ordered separately. Viton® O-rings can be…
-
Replacement thermocouple gauge tubes for AF-0301-01, AF-0301-02 or AF-0303-01.
-
Visiprep™ SPE Manifold Replacement Solvent Guide Needles
MilliporeSigmaFor use with standard, 12- and 24-port models (optional use with 57030-U & 57250-U), stainless steel.
-
Double Vacuum Manifold
SP Wilmad-LabGlassThis borosilicate glass Air-Tite vacuum gas manifold (Schlenk line) is designed with double oblique pressure/vacuum stopcocks with 4mm bores and a 16.2/56 plug size. The stopcocks simplify evacuation or pressurization with an inert atmosphere. Manifold is 1" O.D.
-
Gas Manifold with Vacuum Chambers
DWK Life Sciences (Kimble)An all-glass manifold for connecting inert gas and vacuum sources. Double vacuum gas manifold with vacuum chambers. Fabricated from 1/2" medium wall tubing Stopcocks are 4 mm bore glass with lower vacuum chamber and are spaced 85 mm apart Top right connection is for inert gas and…
-
Vacuum Traps, O-Rings, Airfree®, Schlenk
ChemglassTwo-piece vacuum trap with #15 o-ring joints on both the inlet and outlet ports. The seal between the trap stopper and body is made with a 57mm flat o-ring flange for total grease-free operation when used with either the AF-0060 or AF-0061 manifolds. Trap body is 57mm OD x 300mm in length to be…
-
Flexible and compact, this 4-port line is constructed using CG-474-02, 4mm double oblique hollow high vacuum greased stopcocks on all four ports. Ports are fitted with two 14/20 inner joints and two 24/40 inner joints and are spaced 5" center to center. This configuration permits use directly…
-
Manifold, Tip-Off
Ace GlassUse to tip-off NMR tubes by inserting in lower Ace-Thred port and tightening via bushing. Vacuum line is connected to side hose connection. Tube is then tipped-off with flame. Aluminum shield helps retard heat transfer. Each port individually controlled by smooth acting, semi-needle, threaded PTFE…
-
Sterility Test Manifold
Advantec MFS1-place or 6-place Support cup accepts a No.8 or 8b stopper Features a flushing manifold Applications requiring a closed system, as in sterility testing, use the sterility test manifold. It features a rear-mounted flushing or rinse manifold pipe which allows liquid to be brought…
-
Similar to the AF-0450 5-port line, except that the line is constructed using 0-4mm Chem-Vac™; Chem-Cap®; valves (A) instead of the CG-468-02 greased glass stopcocks on all of the 4-ports. The end cap on the vacuum line is a #30 o-ring joint while the inert gas line has a #9 o-ring joint…
-
Microtest Microplate Manifold
DWK Life Sciences (Wheaton)The stainless steel manifolds (with PTFE stoppers) allow convenient distribution or aspiration in 24- and 96-well plates. They securely fit syringes of the Dosys™ line as well as the Acura 865. Fully autoclavable (121 °C / 250 °F)
-
Main vacuum line with 4ea 24/40 inner ports (A) having a unique configuration of 0-4mm Chem-Vac Chem-Cap®; valves. The valves are sealed to either the vacuum or inert gas side of the manifold and then bent to a 90º angle, forming a strong but very compact assembly. This configuration…
-
Visiprep™ SPE Vacuum Manifold, Standard, 24-Port Model
MilliporeSigmaSPE is a form of chromatography, and, as with other chromatographic techniques, control of flow rate is critical for maintaining reproducible extractions. Unlike other vacuum manifolds, the Visiprep system contains a patented valve system that allows for precise flow control through each SPE tube…
-
Gas Manifolds, 4-Place, PTFE Stopcocks
ChemglassSimilar to CG-1814 but supplied with all PTFE stopcocks.
-
Manifold, Vacuum
Ace GlassAll-glass-and-PTFE vacuum manifold with three, four or five stopcock ports. Each port is a variable opening, 0-10mm, high vacuum threaded stopcock. Plugs are PTFE with Nylon or PTFE handles and FETFE O-Rings. Ultimate vacuum of 10-7 can be realized with O-Rings as supplied. For bakable systems,…
-
Unique design, double bank manifold with the valves sealed in a vertical position. This design permits the user an unobstructed view of whether the valve is in the open or closed position while also exposing the PTFE valves to less outgassing (when the front bank of the manifold is used for inert…
-
Drying Assembly, with Aluminum Holder
Ace GlassOriginally used for Lyophilizing and storing frozen slices of tissue for quantitative histochemistry (see O.H. Lowry, Journal of Histochem. & Cytochem., I, 420, 1953). More recently, used as a vacuum tube with aluminum holders by Nelson & Wakefield, Journal of Neuropathology & Exper. Neurology,…
-
Patented screw-type valves within each SPE port for precise flow control Glass basin will not dissolve, fog, or discolor when exposed to solvents Legs on cover allow user to easily rest cover on work surface when removed from the manifold Screw-type solvent-resistant vacuum bleed gauge and…