Chemicals Assay Kits, BioAssay Systems

Compare Tool

Select up to 3 products

HomeAll Products

BioAssay Systems Chemicals Assay Kits

1 - 32 of 181
Sort
View
Show
  • For sensitive determination of NAD and NADH and evaluation of drug effects on NAD/NADH metabolism. Linear detection range 0.05 - 10 μM NAD+/NADH in 96-well plate assay. Can be readily automated to process thousands of samples per day. Method: OD565 nm. Samples: Cell or tissue extracts.

  • For quantitative determination of urease activity and evaluation/screen for urease inhibitors. Safe. Non-radioactive assay. As low as 0.003 U/L urease activity can be quantified. This "mix-incubate-measure" type assay can be readily automated to process thousands of samples…

  • For quantitative determination of albumin. Use as little as 5 μL samples. Detection range 0.01 - 5 g/dL (1.5 - 750 μM) albumin in 96-well plate assay. Can be readily automated to assay thousands of samples per day. Method: OD620 nm (BCG). Samples: Serum, plasma, urine,…

  • Homogeneous assay for cell viability, proliferation, cytotoxcity and evaluation of anticancer agents Safe. Non-radioactive assay (cf. 3H-thymidine incorporation assay) Sensitive and accurate. As low as 950 cells can be accurately quantified Fast. High-throughput assay using 96-well…

  • BioAssay Systems

    For quantitative determination of DNA. Linear detection range 2 - 40 ng (100 - 2,000 ng/mL) calf thymus DNA in 96-well plate assay. Convenient. Single working reagent. Can readily automated to test tens of thousands of samples per day. Low interference. RNA, salt (up to 3M NaCl),…

  • For quantitative determination of cholesterol and evaluation of drug effects on cholesterol metabolism. Linear detection range 5 - 300 mg/dL cholesterol in 96-well plate assay. Convenient. Room temperature assay. No 37°C heater is needed. Can be readily automated to process…

  • BioAssay Systems

    Sodium Orthovanadate is a general inhibitor for protein phosphotyrosyl phosphatases. BioAssay Systems vanadate reagent is activated for maximum inhibition. Uses: to preserve protein phosphorylation state in cells and lysates. Ready-to-use phosphatase inhibitor. Fully activated for maximum…

  • For quantitative determination of reduced glutathione (GSH) and evaluation of drug effects on glutathione metabolism. Linear detection range 0.4 - 100 μM in 96-well plate. Low interference. Amino acids and common buffers do not interfere. Method: OD412nm. Samples: Whole blood,…

  • For quantitative determination of invertase/sucrase activity. Safe. Non-radioactive assay. "Mix-incubate-measure" type assay. No wash and reagent transfer steps are involved. Can be readily automated to test thousands of samples per day. Method: OD570 nm, or FL530/585 nm. …

  • Direct determination of formate concentrations in biological (e.g. urine, blood, etc.) and other samples. Linear detection range 0.050 to 5 mM Formate. Convenient room temperature assay. No 37°C heater is needed. "Add-mix-read" type high-throughput assay. Method: OD565…

  • For quantitative bioluminescent assay for ADP:ATP ratio (apoptosis) in cells. Safe. Non-radioactive assay. Homogeneous and convenient "mix-incubate-measure" type assay. Can be readily automated to test thousands of samples per day. Method: Luminescence. Samples: Cells.

  • For quantitative determination of D-sorbitol and evaluation of drug effects on sorbitol metabolism. Linear detection range 5 - 1000 μM D-sorbitol. Convenient room temperature assay. No 37°C incubator required. Can be readily automated to test thousands of samples per day. …

  • For quantitative determination of lactate dehydrogenase LDH activity and screen/evaluation of LDH modulators High sensitivity and wide linear range. Use 3 μL serum or plasma sample. The detection limit is 2 U/L, linear up to 200 U/L Homogeneous and simple procedure. Simple…

  • BioAssay Systems

    For rapid, quantitative, bioluminescent determination of ATP and evaluation of drug effects on ATP metabolism. Safe. Non-radioactive assay. As low as 0.02 μM ATP or a single cell can be quantified. Convenient "mix-incubate-measure" type assay. No wash and reagent transfer…

  • For quantitative determination of urea and evaluation of drug effects on urea metabolism. Linear detection range 0.08 -100 mg/dL (13 -17000 μM) urea in 96-well plate assay. Can be readily automated to process tens of thousands of samples per day. Method: OD520 nm. Samples: Serum,…

  • For quantitative determination of total antioxidant capacity (TAC) and evaluation of drug effects on TAC metabolism. Linear detection range from 1.5 to 1000 μM Trolox. The procedure involves addition of a single working reagent and incubation for 10 min. Can readily automated to…

  • For quantitative determination of aconitase enzyme activity and high-throughput screening assays for aconitase modulator. Linear detection range 0.5 to 100 U/L for 20 min reaction. Can be readily automated to process thousands of samples per day. Method: OD565 nm. Samples: Biological…

  • For quantitative determination of zinc ion Zn2+ and evaluation of drug effects on zinc metabolism. Linear detection range 0.12 -10 μM (0.78 - 65 μg/dL) zinc in 96-well assay format. Can be readily automated to process thousands of samples per day. Method: OD425 nm. Samples:…

  • Bright bioluminescent reagent system for rapid quantitation of luciferase reporter gene expression in transfected cells and high-throughput drug screens (for 500 assays). High sensitivity and wide detection range. This fast and homogeneous "mix-and-measure" assay allows detection…

  • For quantitative determination of α-amylase activity. Linear detection range 0.3 to 50 U/L α-amylase in 96-well plate assay. Method: OD585 nm. Samples: Blood, saliva, urine, agriculture etc.

  • For quantitative determination of hemoglobin (Hb) in whole blood. Safe. No hazardous chemicals (e.g. potassium cyanide in Drabkin’s Reagent) used. The "mix-and-read" procedure involves addition of a single reagent and reading the optical density. Can be readily automated…

  • For quantitative determination of ammonia/ammonium concentration by fluorimetry at 360nm/450nm (compatible on handheld fluorimeter catalog# FL360450). Linear detection range of 0.012 - 1 mM ammonia. Can be readily automated to process thousands of samples per day. Method: FL360/450 nm. …

  • For quantitative determination of ethanol and evaluation of drug effects on alcohol metabolism. Linear detection range 0.0008 - 0.1 vol % (140 - 17,500 μM, or 8 -1000 ppm) in 96-well plate assay. Can be readily automated to process thousands of samples per day. Method: OD565 nm…

  • For quantitative enzymatic determination of urea. Fast and sensitive. Linear detection range (20 μL sample): 1 mg/mL (0.17 mM) to 100 mg/mL (17 mM) urea in 96-well plate assay. The procedure involves adding a single working reagent, and reading the absorbance after 5 minutes. Room…

  • Free Amino Nitrogen determination in foods and beverages (e.g. beer, wort, wine, must, etc.) Fast and sensitive. Linear detection range (5 µL sample): 0.2 to 10 mM for 10 min reaction. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be…

  • BioAssay Systems

    Deionized water used for preparation of samples for use with the QuantiQuik™ UreaQuick Test Strips .

  • For quantitative determination of arginase activity and screen for its inhibitors. Sensitive and accurate. Detection limit: 0.3 U/L for 2 hr arginase reaction in 96-well assay format. Simple and high-throughput. The procedure involves incubation of the provided substrate with the sample in…

  • For quantitative determination of lipid peroxides (thiobarbituric acid reactive substances, TBARS) and evaluation of drug effects on lipid peroxidation. Linear detection range colorimetric assay 1 - 30 μM and fluorometric assay 0.1 - 1.5 μM MDA. Method: OD535 nm, or FL560/585 nm. …

  • Direct determination of formaldehyde concentrations in biological, food and environmental samples Safe. Non-radioactive assay. Sensitive and accurate. As low as 1.5 μM (45 ppb) formaldehyde can be quantified. Homogeneous and convenient. "Mix-incubate-measure" type assay. No…

  • For quantitative determination of glyoxalase activity. Note: use a UV plate (e.g. 96-well UV plate, cat# P96UV). Fast and sensitive. Detection Limit 4 U/L GLO-1 Activity. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on…

  • For quantitative determination of D-mannitol in biological, food, beverage and agriculture samples. Linear detection range 0.007 to 3 mM mannitol. Convenient room temperature assay. No 37°C heater is needed. Can be readily automated to test thousands of samples per day. Method:…

  • For quantitative determination of lipase activity. Linear detection range 40 to 1600 U/L lipase activity in 96-well plate assay. Can be automated to process thousands of samples per day. Method: OD412nm. Samples: Serum, plasma, saliva, urine etc.

Compare Tool