This hyper skimmer cone o-ring is used with NexION 1000, 2000, 300 S, 300 Q, 300 X, 300 D and 350 ICP-MS series instruments. The o-ring is also for use with the 2400 Series II CHNS/O Elemental Analyzer.
Commercial quality ground and polished clear fused quartz discs. Edges have a ground finished on all sizes.
Fused quartz has been chosen because of its very high purity and low thermal expansion rate. Because we care about your safety, all combustion tubes are pressure-tested to eliminate any tubes which might contain weak spots. In addition, stringent specifications are used to insure that the combustion...
Glass Lined Unions by SGE are designed to facilitate secure connections in gas chromatography systems while minimizing the risk of contamination. The glass lining ensures chemical inertness, maintaining the integrity of sensitive samples. These unions are built to withstand high-pressure...
Includes six preformed wires. PerkinElmer's Platinum Hangdown Wire Kit is specifically designed for use in gas chromatography applications. Composed of high-purity platinum, the wires ensure accurate and reliable results in analytical procedures. This kit provides the necessary components to enhance...
Can be used with Argonor Nitrogen and hasa CGA 580 fitting. Acolor-coded hose with1/4-inch SWAGELOKfittings is also included. Max Inlet Pressure:3000 psig
Rechargeable Desiccant Kit comes with four desiccant cartridges. Rechargeable desiccant cartridges are contained in rigid metal cages which are user-installable. Two cartridges are required for Spectrum 65/100/100NTS/400 and Frontier spectrometers. It is recommended to have spare desiccant...
User replaceable parylene-coated potassum bromide sample compartment windows compatible with Spectrum One/100 and Frontier Optica.
The PerkinElmer one-piece fitting with a 1/16 Inch inside diameter features a 10-32 thread connection for a finger-tight seal and the PEEK material construction provides more strength.
High solids GemCones are for samples with high dissolved solids (up to 20%). This conespray nebulizer allows you to analyze samples with higher solids concentration than is possible with a Cross-Flow nebulizer. GemCone nebulizers require an end cap for use with Scott Spray Chambers. This is a 10...
The 10 cm burner head is designed to be used with the air-acetylene flame. Because of its long burner path length, it provides the best sensitivity for air-acetylene elements.
Low dead volume High temperature applications No back ferrules needed Can be used with Graphite, Graphite Vespel® or PTFE ferrules Suitable for glass, fused silica, metal, plastic or glass lined tubing Non-swaging and no tube distortion
Two Viton 6.07 mm I.D. o-rings are included each in the Scott/Cross-Flow Torch Injector O-Ring Kit (N0790440) and the Cyclonic/Concentric Torch Injector O-Ring Kit (N0790441).
The Transflectance Liquids Sampling Accessory Starter Kit includes five liquids reflectors, five Petri dish bases, Transflectance Liquids Sampling procedure, and user guide. Compatible with NIRA, NIRA II and NIRM near-infrared reflectance accessories.
By using rectangular windows instead of circular windows, the demountable cell becomes a semi-demountable cell. The semi-demountable cell can be used either as a demountable cell or as a sealed cell for high-viscosity liquids or mull samples. To order a semi-demountable cell, order the Universal...
Gas Pressure Regulator Features: Barstock Body Construction Barstock bodies have a lower internal volume than forged bodies, allowing for more complete purging of atmospheric contaminants. Stainless Steel DiaphragmsUnlike elastomeric diaphragms, stainless steel diaphragms don't absorb atmospheric...
PerkinElmer is expanding its compressor product portfolio to include an industrial grade, quite, oil-less compressor for dependable and clean air supply. With the addition of a water separator with a 5 micron particle filter, no liquid transfers into the air supply, providing you with contaminant...
Cylindrical cells are used with spectrophotometers that have a larger, circular light beam. Each cell has an outside diameter of 22 mm and an inside diameter of 19 mm. Each package contains one cell and two windows.
The sealed liquid cells have a corrosion-resistant construction making them ideal for highly volatile samples. The sealed liquid cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. These cells use a lead spacer which is amalgamated to the window...
For use with the 2400 in the CHNmode and with the 2410. pkg. 1
Oxygen regulator, two stage HP Brass regulator, SS diaphragm, Delivery Pressure 0-50 PSIG, 1/8 Ultra-Torr Fitting. With CGA 350 fitting.
Indicates that SCHOTT type UK 5 is used for cells referred to in the catalog as manufactured from “Special Optical Glass”. This crown glass is made from exceptionally pure raw materials, which gives an improved transmission in the near ultraviolet range. An empty cell will give a transmission of...
The PerkinElmer 10 Feet cable to PC serial port is used for obtaining optimum connectivity and communication.