Chromatography Columns

Chromatography Columns

Products (6370)

Compare Tool

Select up to 3 products

  • < Previous
  • > Next
  • PLOT Gas Chromatography Column

    Agilent Technologies

    Agilent J&W HP-PLOT Molesieve are offered in 0.53 and 0.32 mm id. For applications requiring resolution of argon and oxygen without expensive cryogenic cooling, select thick-film HP-PLOT Molesieve columns. The thin-film configurations are ideal for many applications, including routine air monitoring...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Rt-Alumina BOND/CFC Columns (fused silica PLOT)

    Restek Rt-Alumina BOND columns are highly selective for C1–C5 hydrocarbons and separate all saturated and unsaturated hydrocarbon isomers above ambient temperatures. The reactivity of the aluminum oxide stationary phase is minimized, by deactivation with inorganic salts like KCl or...

  • Aquasil C18 3µm Columns

    Thermo Scientific

    Polar endcapped C18 phase Alternative selectively compared to conventional C18 phases Compatible with 100% aqueous mobile phases Thermo Scientific Aquasil C18 HPLC Columns provide greater retention than C18 for polar molecules.

  • GC Capillary Column

    Agilent Technologies

    Gas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,...

  • InfinityLab Poroshell 120 UHPLC Guard Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Bond Elut 96-Square-Well Plate

    Agilent Technologies

    Bond Elut 96 square-well plates facilitate transfer from cartridge-based methods to 96-well plate automated formats. The 2 mL wells accommodate the larger processing volumes from older methods, easing method transfer and revalidation. When larger samples or wash volumes are required, the 2 mL well...

  • OPTIMA® 5 Capillary Columns

    OPTIMA® 5 Capillary columns for GC Features 5 % phenyl – 95 % methylpolysiloxane · USP G27, G36 Nonpolar standard phase with large range of application Low bleed columns with equal selectivity see OPTIMA® 5 MS, ultra low bleed columns see OPTIMA® 5 MS Accent Similar phases:...

  • GC Ultra Inert Column

    Agilent Technologies

    Agilent J&W Ultra Inert DB-BAC1 and DB-BAC2 columns are part of the Agilent J&W Ultra Inert GC column family capable of separating t-Butanol and n-Propanol from frequently encountered interferences in blood matrix. The unique polarity of the columns provides excellent selectivity when using this...

  • Polaris HPLC Column

    Agilent Technologies

    Agilent Polaris HPLC columns offer many polar phase chemistries designed separate mixtures of polar and nonpolar analytes reliably and with excellent peak shapes. The polar-embedded C8 and C18 bonded phases are compatible with 100% water, and offer alternative selectivities while still complying...

  • Bond Elut Solid Phase Extraction Cartridge

    The Bond Elut Certify extraction cartridge is a mixed mode sorbent containing nonpolar and C8 strong cation exchanger functionalities. Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but is also effective for the extraction of many compounds from a diverse range...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • ZORBAX Extend 80A C18, 2.1 x 150 mm, 5 um

    ZORBAX Extend 80A C18, 2.1 x 150 mm, 5 µm HPLC column. ZORBAX Extend-C18 columns have high efficiency and a long life at high pH with more effieincy and better peak shape than polymer-based columns. Agilent Technologies products are intended for sale/shipment within the US only. International...

  • TSKgel® SW Type Guard Column phase diol, L × I.D. 7.5 cm × 7.5 mm, 10 µm particle size

    Synonym: TSKgel® Size Exclusion (SW-Type) HPLC Guard Column General Description Guard Column for 7.5mmID TSKgel G2000SW, G3000SW and G4000SW columns TSKgel Guard Columns are stand-alone and do not require separate holders. Physical Form Shipped in 0.05% NaN3 and 0.1 mol/L Na2SO4 in 0.1 M...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Sep-Pak Silica Plus Light Cartridges

    Polar sorbent, used primarily to adsorb analytes from non polar solvents like hydrocarbons, chloro- or flouro-substituted hydrocarbons or less polar esters and ethers.

  • GC Capillary Column

    Agilent Technologies

    Gas Chromatography (GC) columns are at the heart of the gas chromatograph and responsible for the separation process. GC is one of the most important and critical tools in analytical chemistry, because of its effectiveness, sensitivity and ease-of-use. GC columns contain a stationary phase,...

  • Low Thermal Mass Column Module

    Agilent Technologies

    Agilent J&W Ultra 2 is a (5%-phenyl)-methylpolysiloxane, nonpolar column that resembles HP-5, but with tighter specifications for retention index and capacity factors. It has an operating temperature range of -60 to 325/350 °C and is intended for use with the Sadtler Retention Index Library. These...

  • Kromasil® C18 HPLC Columns

    application(s) HPLC: suitable matrix active group C18 (octadecyl) phase suitability suitable for L1 per USP

  • Self Tightening Column Nut Kit

    Agilent Technologies

    One of the most basic tasks in GC, installing the column, can be challenging. The GC oven is a dark, small space, and column installation uses some tiny parts that need to be assembled with precision. Installation of the column into both the inlet and detector must be done properly to get accurate...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • ZORBAX PrepHT Bonus-RP and Extend-C18 Columns

    Easy scale-up from analytical to preparative scale with ZORBAX phases Fast preparative separations, up to 2000 mg 5 to 7 µm particles for high efficiency and high yield Easy to install finger tight connections seal up to 5000 psi/350 bar High purity, high recovery and high throughput can be...

  • InfinityLab Poroshell 120 Method Validation Kit

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut NH2 is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged). It is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond...

  • < Previous
  • > Next

Compare Tool

Select up to 3 products