Chromatography Columns

Chromatography Columns

Products (6370)

Compare Tool

Select up to 3 products

  • < Previous
  • > Next
  • PLOT Gas Chromatography Column

    Agilent Technologies

    Agilent J&W HP-PLOT Al2O3 S is the standard column choice for light hydrocarbon analysis, particularly C1 to C8 hydrocarbon isomers. A mid-polar range alumina phase deactivated with sodium sulfate, it is excellent for resolving acetylene from butylene and isobutane. This product is only available to...

  • WAX Gas Chromatography Column

    Agilent Technologies

    Agilent J&W CP-Wax 52 CB is a high-polarity polyethylene glycol (PEG) phase with a wider temperature range than nonbonded PEG columns, due to extensive crosslinking. This column delivers higher resolution of low boiling point analytes, with guaranteed reproducibility and excellent temperature...

  • Gas Chromatography Column

    Agilent Technologies

    Agilent J&W HP-5ms Ultra Inert is a (5%-phenyl)-methylpolysiloxane specifically tested for inertness in the analysis of active compounds, including acidic and basic compounds, to meet the growing need for lower detection levels. With very low bleed characteristics, this bonded and crosslinked column...

  • Metal Gas Chromatography Column

    Agilent J&W CP-SimDist UltiMetal performs extended analysis to C120, and is guaranteed to a Tmax of 450 °C, due to the virtually unbreakable inert UltiMetal tubing. The internal diameter of UltiMetal tubing is the same as for fused silica 0.53 mm id (Megabore) columns, providing trouble-free...

  • Hypersil ODS, 3 um, 4.0 x 100 mm cartridge (AC)

    Hypersil ODS, 3 µm, 4.0 x 100 mm cartridge (AC) (use with hardware kit 5021-1845) Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies...

  • Metasil Conventional HPLC Column

    Metasil® HPLC column - excellent peak shape for basic analytes. Exceptionally high surface coverage. Improved polar compound retention. Enhanced selectivity. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut ENV, a PS-DVB polymer, is designed for the extraction of polar organic residues. It contains 125 µm spherical particles, advantageous for high volume, fast flowthrough applications. This product is only available to U.S. Domestic Customers. For research use only, not to be used in...

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W CP-Sil 24 CB is a medium polarity, 50% phenyl/50% dimethylpolysiloxane phase with no cyano groups, making it ideal for use with ECD. The column produces perfect peak shapes for amines as shown by the Grob test mixture. It is especially suitable for the analysis of drugs and pesticides...

  • InfinityLab Poroshell 120 UHPLC Guard Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • InfinityLab Poroshell 120 Reversed-Phase Liquid Chromatography Column

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut C2 is a fairly nonpolar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions....

  • TraceGOLD TG-WaxMS B GC Columns

    Base deactivation allows analysis of basic analytes without derivatization or column priming Polar phase, base deactivated polyethylene glycol phase Reduced absorption and improved responsiveness for basic compounds Not suitable for use with water or alcohols Applications: Amines Alkylamines...

  • MetaCarb 87K Column 300 x 7.8mm

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • ChromSpher 5 Si 250 x 4.6mm

    Agilent Technologies

    Agilent Technologies products are intended for sale/shipment within the US only. International customers should contact their local Agilent Technologies distributor to place orders for Agilent Technologies products.

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut PRS, the presence of the benzene ring in the functional group increases the potential for nonpolar interactions. This nonpolar characteristic becomes particularly important when conducting ion...

  • APS-Hypersil-2 5µm Columns

    In reversed phase mode, Hypersil APS-2 columns are excellent for carbohydrate analysis: extra sensitivity for sugars Alternative selectivity to silica when used in normal phase Thermo Scientific Hypersil APS-2 Columns have a versatile amino propyl phase with excellent chromatographic properties in...

  • GC Capillary Column

    Agilent Technologies

    Agilent J&W CP-Sil 8 CB is a general-purpose phase that incorporates 5% phenyl groups in the dimethylpolysiloxane polymer, giving it slightly higher polarity than CP-Sil 5 CB. This delivers better selectivity for aromatic compounds and makes it the best choice for method development. Equivalent to...

  • Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines (fused silica)

    Tested with a comprehensive test mix, to ensure high inertness Revolutionary deactivation process for superior inertness Analyze active samples accurately; ideal for chlorinated pesticide analysis (reduces endrin breakdown to less than 1%) Maximum temperature: 380°C

  • DB-ALC1 And DB-ALC2

    Agilent Technologies

    Meets EN14110 standard Reliable blood alcohol analysis Optimized primary and confirmation column pair for U.S. blood alcohol analysis Faster GC run times Improved resolution of key ethanol/acetone peaks Available in 0.32 and 0.53 mm ID Bonded and cross-linked Similar Phases: Rtx-BAC1, Rtx-BAC2...

  • InfinityLab Poroshell 120 Method Validation Kit

    InfinityLab Poroshell 120 superficially porous columns for reversed-phase liquid chromatography (LC) separations offer exceptional efficiency and reliability. Twenty chemistries - from various C18 columns to other unique phases - are available in up to three particle diameters: 1.9 µm, 2.7 µm, and 4...

  • Bond Elut Solid Phase Extraction Cartridge

    Bond Elut CH is a midpolarity sorbent that exhibits unique selectivities for certain analytes. When employed as a nonpolar sorbent, CH has the approximate polarity of a C2 sorbent. Bond Elut CH is often a good choice when nonpolar sorbents, such as C18, C8, or C2, do not provide the desired...

  • OPTIMA® 5 Amine Capillary Columns

    OPTIMA® 5 Amine GC capillary columns for amine separation Features Especially deactivated for the analysis of polyfunctional amines such as ethanol­amines, amino-functionalized diols and similar compounds, which are important base materials in industrial chemistry, and show strong tailing on...

  • Metal Packed GC Column (General Configuration) phase none, matrix 40/60 Carboxen-1000 support

    Packed column made up of stainless steel are basically employed when higher carrier gas flow rates are employed as they can sustain elevated pressure. Stainless steel columns are usually washed with dilute hydrochloric acid, then with water followed by methanol, acetone, methylene dichloride and...

  • PLRP-S Polymeric Reversed-Phase LC Column

    PLRP-S for Biomolecules products are available in a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives...

  • < Previous
  • > Next

Compare Tool

Select up to 3 products