Advantec MFS

Advantec MFS

Products (77)

Compare Tool

Select up to 3 products

  • Large Stainless Steel Pressure Filter Holders

    90mm, 142mm, and 293mm filter diameters Available in type 304ss or 316ss Large Stainless Steel Pressure Filter Holders are offered in various sizes for batch type laboratory filtration or continuous filtration operations using disc media. Advantec holders have been designed to minimizes resistance...

  • Quantitative Ashless Filter Paper, No. 6

    Advantec Quantitative Ashless Filter Papers are made from the highest quality alpha cotton cellulose. One critical step in the manufacturing process of these filter papers is acid washing. All grades are double acid washed in hydrochloric then hydrofluoric acid to reduce levels of SiO2, CaO, and...

  • Stainless Steel Vacuum Manifold

    1-place, 3-place, or 6-place Standard cup accepts No.8 or 8b stopper Choice of 2- or 3- way valves Vacuum manifolds allow filtration of multiple samples either at once or independently by controling the separate branch valves. The durable type 304 stainless steel can be used for applications in...

  • Non-Sterile Mixed Cellulose Esters (MCE) Membrane Filters - Black, 0.80µm

    Available pore sizes: 0.10µm, 0.20µm, 0.30µm, 0.45µm, 0.65µm, 0.80µm, 1.0µm, 3.0µm, 5.0µm Colors: White, Black, and Green Surfaces: Gridded or Plain Nonsterile bulk pack Mixed Cellulose Esters (MCE) membrane is a general purpose filter used in...

  • Quantitative Ashless Filter Paper, No. 5B

    Advantec Quantitative Ashless Filter Papers are made from the highest quality alpha cotton cellulose. One critical step in the manufacturing process of these filter papers is acid washing. All grades are double acid washed in hydrochloric then hydrofluoric acid to reduce levels of SiO2, CaO, and...

  • Syringe Filters and 50mm Units, Sterile - MCE, CA, NY, PES, PTFE

    •  3mm, 13mm, 25mm, 50mm •  0.10µm to 1.20µm •  Minimal sample hold-up •  High purity, non-pigmented housing and no adhesives used Advantec MFS offers a broad selection of filter media in convenient sterile disposable syringe filters and 50mm...

  • PVC Manifold

    Advantec MFS

    Lightweight Resistant to acids Standard cup accepts a No.8 or 8b stopper Lightweight and durable PVC material makes this vacuum manifold a great alternative to stainless steel. Polyvinylchloride(PVC) is resistant to acids. The standard cup accepts a No.8 or 8b stopper to adapt to microanalysis units...

  • Glass Fiber Filters, Thicker for Viscous Liquids

    Advantec Glass Fiber Filters are depth filters made of pure borosilicate glass microfibers. These grades are thicker and have a high loading capacity and typically faster flow times. Recommended for filtering viscous fluids such as proteinaceous solutions and gels and as prefilter to extend membrane...

  • 90mm Glass Vacuum Holder Assemblies

    Filter larger volumes of liquid  Filter viscous, heavy particle or biobuden samples Sintered glass or Stainless steel support Borosilicate glass filter holder assemblies for the microanalysis of liquids for biological or particulate contamination under vacuum. The 90mm holder offers an...

  • Non-Sterile Mixed Cellulose Esters (MCE) Membrane Filters - Green, 0.45µm

    Available pore sizes: 0.10µm, 0.20µm, 0.30µm, 0.45µm, 0.65µm, 0.80µm, 1.0µm, 3.0µm, 5.0µm Surfaces: Gridded or Plain Nonsterile bulk pack Mixed Cellulose Esters (MCE) membrane is a general purpose filter used in many applications for the...

  • Qualitative Filter Paper, No. 232

    Advantec Qualitative Filter Papers are made of 100% cotton linter cellulose. Primarily used for clarifying and removing precipitates (ppt) and preparation for quantitative analysis. These papers can be used over a pH range from 0-12 and a maximum temperature of 120°C. Ash content of 0.1%. Papers...

  • Qualitative Filter Paper

    Advantec Qualitative Filter Papers are made of 100% cotton linter cellulose. Primarily used for clarifying and removing precipitates (ppt) and preparation for quantitative analysis. These papers can be used over a pH range from 0-12 and a maximum temperature of 120°C. Ash content of 0.1%. Papers...

  • Quantitative Ashless Filter Paper

    Advantec Quantitative Ashless Filter Papers are made from the highest quality alpha cotton cellulose. One critical step in the manufacturing process of these filter papers is acid washing. All grades are double acid washed in hydrochloric then hydrofluoric acid to reduce levels of SiO2, CaO, and...

  • Stainless Steel Extraction Manifold

    1-place, 3-place, or 6-place Tapered branch accepts 40/35 female joint Choice of 2- or 3- way valves Vacuum manifolds allow filtration of multiple samples either at once or independently by controling the separate branch valves. The durable type 304 stainless steel can be used for applications in...

  • Advantec Mfs™ AISI 304 Stainless Steel Vent Relief Valve

    Material Stainless Steel (AISI 304) Max. Pressure 7 bar Quantity 1 Ea. Type Relief Valve

  • Qualitative Filter Paper, No. 231

    Advantec Qualitative Filter Papers are made of 100% cotton linter cellulose. Primarily used for clarifying and removing precipitates (ppt) and preparation for quantitative analysis. These papers can be used over a pH range from 0-12 and a maximum temperature of 120°C. Ash content of 0.1%. Papers...

  • Chemically Resistant PFA In-Line Filter Holders

    Filter acids, alkalis, or organic solvents Dual support screens allow flow in either direction Perfluoroalkoxy(PFA) polymer is very similar to PTFE resin. The PFA holder offers superior chemical compatibility and can be used with chemically aggressive liquids. Dual support screens allow for flow in...

  • Qualitative Filter Paper, No. 101

    Advantec Qualitative Filter Papers are made of 100% cotton linter cellulose. Primarily used for clarifying and removing precipitates(ppt) and preparation for quantitative analysis. These papers can be used over a pH range from 0-12 and a maximum temperature of 120°C. Ash content of 0.1%. Papers...

  • Glass Fiber Filters, Air Monitoring

    Advantec Glass Fiber Filters are depth filters made of pure borosilicate glass microfibers. Highly resistant to chemical attack and biologically inert. Binder-free and thermostable to 500°C. These grades are recommended primarily used in environmental air monitoring applications. Grade GB100R...

  • Non-Sterile Mixed Cellulose Esters Membrane Filters - White, 0.45µm

    Available pore sizes: 0.10µm, 0.20µm, 0.30µm, 0.45µm, 0.65µm, 0.80µm, 1.0µm, 3.0µm, 5.0µm Colors: White, Black, and Green Surfaces: Gridded or Plain, with or without Hydrophobic Edge (HE) Nonsterile bulk pack Mixed Cellulose Esters (MCE)...

  • PTFE Depth Filters

    Pure PTFE (Polytetrafluoroethylene) fibers are sintered to create a unique depth-type filter. These PTFE filters offer superior handling and minimal fiber slough-off compared to glass and quartz filters. Naturally hydrophobic, the media will separate aqueous from non-aqueous phases of mixtures....

  • 25mm Glass Vacuum Holder Assemblies

    Filter small volumes  3 funnel sizes available Sintered Glass or Stainless Steel support Borosilicate glass filter holder assemblies for the microanalysis of small volumes of liquids for biological or particulate contamination under vacuum. The holder utilizes a 25mm filter membrane. The...

  • Glass Fiber Filters, Water Quality Testing

    Advantec Glass Fiber Depth Filters feature high-loading capacity, fast flow rates, are highly resistant to chemical attack, and biologically inert. General purpose and clarifying filtration grades. Binder-free and thermostable to 500°C. Grade GA55 is a thin filter recommended for clarifying...

Compare Tool