Air

Compare Tool

Select up to 3 products

1 - 32 of 74
Sort
View
Show
  • The SAS Super 100 & 180 microbial air samplers are the top choices of the world's leading pharmaceutical and food companies, as well as numerous governments around the world for detection of microbial contamination and air quality testing. Featuring a powerful, high volume air flow of…

  • Filters Change Indicators Stickers for Acids, Aromatic diisocyanates, Basic Vapors, Halogens, Hydrazine, Formaldehyde, Hydrogen Sulfide, Mercury and Methyl Ketones. The Breakthrough (Saturation) indicators Stickers (BTIS) for ductless hood filters are colorimetric indicators that indicate the…

  • Filter support assembly for collecting dust particles in a stack sampling system. Available in either 51mm (2"), 76mm (3") or 102mm (4") (illustrated) size. Consists of: PART A, with 28/15 outer joint bent perpendicular to flow path; PART B, with seat for fritted disc and 28/15 inner…

  • A high velocity impinger for the determination of dust concentration in air or other gases. Total volume is approximately 500mL. Bottle joint is 45/50. Inlet/outlet are 12.5mm O.D. Modified versions available with spherical joints both vertical for connecting in series. Available with or without…

  • The MAS-100 NT® microbial air monitoring systems are high performance, portable, battery operated instrument which are based on the principle of the Andersen air sampler. These compact yet sophisticated devices are the preferred choice for those demanding the highest quality in microbial air…

  • Collection bottle, usually connected to the bottom arm of the 7495 tee with reduced ends, to collect heavy particulates before they enter the manifold train.

  • Flexible Non contaminating On/off valve closure Use for gas or liquid sample containment Heat-sealed seams for leak-proof operation Reusable bags made of 2 mil PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of non-corrosive gases.…

  • Ace Glass

    With 14/20 or 19/22 joints, outer joint at top and inner at bottom. Size B hose connection is on side.

  • The HPLC Solvents Breakthrough Indicator is qualitative (yes/no) colorimetric indicator of the end-of-service life of low-flow filters. It is designed to provide real-time indication of the saturation and breakthrough of hplc solvents. HPLC solvents include Acetone, Acetonitrile, Chloroform,…

  • Ace Glass

    Identical to 7531-10 with the exception that the nozzle is replaced by a sintered glass filter, porosity A (145-175 microns). Used in determination of Acrolein: 4-Hexylresorcinol Method #1. Bottle has encircling graduations from 0 to 25mL or 0 to 30mL in 5mL divisions. Inlet/ outlet are 7mm O.D.…

  • Flexible Non contaminating Septum closure Use for gas or liquid sample containment Heat-sealed seams for leak-proof operation Reusable bags made of 2 mil PVDF fluoropolymer film, Chemware® Gas Bags offer an economical alternative for analysis of non-corrosive gases. Durable, heat-sealed seams…

  • Ace Glass

    Bubbler with either fritted tip or plain orifice stopper. Bottle has 24/40 joint and 10 cm tube below bulge. Stopper has 12/5 outer joint on inlet arm and 12/5 inner on outlet arm. Fritted tip is porosity C (25-50m). Orifice tip is 1.5mm capillary with end tapered. Approximate capacity, with…

  • Primarily designed for use with ACE 8051 bearings. The inner tube through which the stirring shaft passes, plus the PTFE O-Ring supplied with each unit, prevents the lubricant or foreign particles from contaminating the flask contents. For replacement PTFE ring, order 8113-89.

  • Sartorius

    The MD8 series of air samplers are monitoring devices combined with novel filtration systems for the exceptional recovery of airborne microorganisms. MD8 AirScan: (Integrated) Quantitative detection in sterile areas such as clean rooms/RABS, isolators, or blow-fill-seal machines. …

  • Borosilicate glass vacuum/NO-AIR trap. Simliar to 8755 traps but with No. 15 O-Ring side connecting joints. Ideal for vacuum cart and other vacuum or NO-AIR applications. Comes complete with stainless steel ball-joint clamp and Viton O-Ring.

  • Permanent split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v…

  • Air sampling cane with funnel at one end to avoid water droplets from collecting at edge and being sucked into manifold train. Bulge above the funnel is for glass wool or similar material to allow for filtering of particulates. Codes -22 & -26 feature a #7 Ace-Thred port for introducing calibration…

  • Cole-Parmer

    Instantly cool electrical components to -65°F (-53.8°C). Dries fast and leaves no residue  Quickly deliver freezing power to hard-to-reach places  Ultra-low global warming potential (GWP)  Nonflammable and ozone safe.

  • Ace Glass

    7493 air sampling cane 6.4mm mesh PTFE screen assembly. Only available for our 25mm OD canes. Place the screen within the retaining ring, unfasten the yoke's nut & bolt, pass the now open yoke around the funnel and then tighten the nut and bolt to secure the assembly. The screen is held in place…

  • Ace Glass

    Consists of bottle with hex base and 45/50 joint, SO2 bubbler stopper with 25 mm diameter Por. C (25-50m) fritted disc, and impinger stopper. Capacity, 275mL. Inlet/outlet are 8mm.

  • Adjustable bleed adapter used for reducing air flow in the Air Sampling Manifold to prevent a pressure drop across the sampling ports. Normally installed in front of the 7511 blower, in line with the manifold. Positioning of holes in threaded nylon plug controls the volume of air flow. Plug…

  • The TRIO.BAS™ instruments utilize the impaction method of air sampling. The air, passing through an aspirating head, impacts onto an appropriate agar plate that collects bacteria or other organic substances possibly present in the sampled area. All of our air samplers are lightweight,…

  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Graduated Schlenk storage tube with 14/20 or 24/25 outer top joints, 14/35 or 24/40 inner joint side arms, stopcock inlet or hose barbed inlet valve. Reaction accessories include 7759 series filter tubes, 7807 series finger condenser, 9543 series stoppers and 13657-33 stirring magnet..

  • Ace Glass

    Glass Manifold with #15 Ace-Thred at either end To allow switching 5853 vacuum connection to left or right side. Supplied with three or five, 4mm straight bore PTFE stopcock sampling ports. (Additional ports can be ordered.) Overall length of glass manifold is 230mm. Complete item consists of 8763…

  • Automatic, adjustable pressure release valve for safer operation of pilot plant or other assemblies where the pressure is of great concern. The tension on the stainless steel spring determines the amount of pressure needed to force the lower piece open. With the spring supplied, the range is 15-50…

  • Environmental Sampling Supply

    The ESS Air Sampling Bag incorporates a two opening system for sampling and extraction. The side port/stem (3/16" OD) allows filling with a pneumatic pump and tubing, and for rapid emptying of the bag. The top of the valve is

  • Falcon

    100% Ozone-safe Pure moisture-free blasts Extension tubes for precise dusting Ideal for cleaning in laboratories, photographic equipment and computers. The Special Application Formula (2905T03) has been formulated for use in especially sensitive environments, such as scientific…

  • Straight tube type air sampling cane with polyethylene hood and stainless steel brackets. Codes -35 & -37 feature a #7 Ace-Thred port for introducing calibration gases.

  • With standard U shape gauge made of heavy barometer tubing and mounted on a wooden panel for vertical suspension. The scale is adjustable and accurately calibrated. Supplied with scale and tubes, but without mercury.

  • Glass Manifold with #15 Ace-Thred at either end to allow switching vacuum connection to left or right side. Supplied with three or five 0 - 4mm High Vacuum, Easy Action Stopcocks for sample ports. Plugs are PTFE with Nylon hooded handles and FETFE O-Rings. Ultimate vacuum of 10 - 7 can be realized…

  • A high velocity impinger air sampling which passes 6L/min (corrected to engineering gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.035in capillary tip that is…

Compare Tool

Select up to 3 products