PerkinElmer ICP-MS
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
PFA MicroFlow high solids large bore nebulizer with external 1/4-28 threaded connector. Ideal for strong acids, high solids, alkalis, organic solvents, soils and high salt solutions.
-
Demountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
Capillary Tubing 18 0.043 x 0.017 for Mira Mist
PerkinElmer0. 5 meters of . 044 OD X . 018 ID. Clear Polyethylene Tubing with attached BRC 3 fitting for sample lines.
-
The GemCone low-flow nebulizer permits lower nebulizer flow rates, useful for spectral lines with high excitation energies and for providing a more robust plasma. The nebulizer is optimized for low nebulizer gas flow for use with cyclonic spray chambers. It requires an end cap (N0680504) for use…
-
PerkinElmer's HybridXLT torch is the latest addition to the family of PerkinElmer genuine sample introduction components. The new ceramic/quartz hybrid design provides the highest performance for your Optima ICP-OES 8x00 spectrometer. This new torch has an extended lifetime of up to 10x your…
-
This kit includes: Glass Standard Cyclonic Spray Chamber (N0776052) Cyclonic Spray Chamber Mount Kit (N0770131) Cyclonic Spray Chamber Mount Nut (N0776005) Cyclonic Spray Chamber Mount Sleeve (N0776004) Cyclonic Spray Chamber Mount Ring (N0776003) 20 mm M4 Cap Screw (09919167) 6 mm M3 Cap…
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are…
-
Cyclonic spray chamber drain fitting
PerkinElmerCyclonic spray chamber drain fitting with ETFE capillary tubing - 24 length by 0.030 ID x 0.062 OD.
-
F2 Standard Integrated Capillary
PerkinElmerF2 Standard Integrated Capillary (standard fitting with + nebulizers). F2 Standard integrated capillary for self-aspiration or pumping. Includes 0. 5 mm i.d. (orange marker) 70 cm long capillary.
-
The D-Torch is a revolutionary new demountable torch design with interchangeable outer Tubes. Quartz outer Tubes are ideal for most aqueous samples, while ceramic outer Tubes last longer for samples with high dissolving solids or for organic applications, such as wear metals in engine oils.
-
3-Slot Quartz Torch for Optima 4300/5300/7300 V
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
This kit includes: Demountable Quartz Torch PVDF qty.2 (N8152379) 2.0 mm Demountable Quartz Injector qty.2 (N8152376) Torch Injector Nut qty.2 (N8152451) Glass Cyclonic High Sensitivity Spray Chamber with Matrix Gas Port qty.1 (N8152389) Threaded Spray Chamber Drain Line qty.2 (N8152456) …
-
This kit includes: O-Ring 15.5 mm I.D., Qty. 1 (09902155) O-Ring 6.07 mm I.D., Qty. 2 (09902207) O-Ring 9.25 mm I.D., Qty. 2 (09902247) O-Ring 7.65 mm I.D., Qty. 1 (09926070)
-
PFA-200 Microflow Nebulizer 20 uL/min
PerkinElmerPFA-200 Microflow Nebulizer, 200 µL/min, with integrated autosampler probe [Ultem support] for ESI SC Autosampler. HF Resistant. Capillary length 150cm. Probe length 175 mm.
-
The SeaSpray Concentric Nebulizer is ideal for samples with high dissolved solids and offers outstanding nebulization effciency for trace level analysis. It offers freedom from clogging while nebulizing solutions near the limit of solubility of most mineral salts, and conferring signifcant…
-
The PEEK Ari Mist ® nebulizer provides very low sample flow and is for samples that are particlate free. Operates on stand pressures of 40 - 50 psi. Fits regular spray chambers as a direct replacement for glass concentric nebulizers. Its features an enhanced parallel path design.
-
Adjustable Torch O-Ring Kit for Avio 200/500
PerkinElmerThis kit includes: O-Ring 20.3 mm I.D., Qty. 2 (09902223) O-Ring 2.57 mm I.D., Qty. 2 (N0791334) Plastic O-Ring Removal Pick, Qty. 1 (09220410)
-
This quartz hydride gas-liquid separator is used with all hydrideFAST autosampler systems.
-
1-Slot Quartz Torch for Optima 8x00
PerkinElmerDemountable design using one-piece quartz tubing for plasma and auxiliary gas flow. Available in a wide range of styles from 0-slot to 3-slot torches, depending on instrument and application needs. Torches without slots are recommended for organic solvents. 1-slot torches are the standard torch for…
-
ST3 MicroFlow PFA nebulizer
PerkinElmerThe ST3 MicroFlow PFA nebulizer has an exchangeable external sample uptake capillary. The sample uptake rate is controlled by the diameter of the external capillary or probe.
-
MicroFlow nebulizers are resistant to clogging, reliably self-aspirated or pumped to produce a fine aerosol for high transport efficiency and high sensitivity. The PFA-ST3 Nebulizer is designated for superior clog resistance and higher sensitivity compared to the standard PFA nebulizer. • All PFA…
-
The Axial View Purge Extension Window is a replaceable quartz window that slides into the purge extension between the torch and the optics. The Radial View Purge Extension Window Tube is a replaceable quartz Tube that slides into the mount between the torch and the optics for the radial view.
-
The water-cooled design permits the introduction of coolant for temperature control. Thermostatting to constant temperature helps ensure highly reproducible results and long term stability. Can also be cooled to suppress volatilization, allowing the direct aspiration of highly volatile solvents…
-
The PC 3 is a small, robust Peltier cooled cyclonic spray chamber. The PC 3 offers the advantages of low memory effects, constant temperature, fast rinse-out, and high sample transport efficiency. The cooled outer walls of the PC 3 spray chamber enhance long-term signal stability, reduce…
-
Eluo Nebulizer Cleaner
PerkinElmerEluo Nebulizer Cleaner Particle build-up in a nebulizer capillary and tip causes sample flow to be constricted, thereby reducing nebulizer efficiency andperformance. Previously there was no simple way to effectively clean and unblock nebulizers. Now, blocked nebulizers can be safelyand easily…
-
Replacement connector and sample tubing for glass concentric nebulizers with EzyFit sample inlet.
-
Adjustable Torch Mount Assembly for Avio 200
PerkinElmerThe adjustable torch mount assembly is included in the Adjustable Torch Body Assembly (N0790138). This assembly includes: Torch Mount, Qty 1. (N0791285) Disk Magnet, Qty. 1 (09200515)
-
This baffled cyclonic spray chamber, made of borosilicate glass, is an integral part of the sample introduction system responsible for filtering the sample mist to permit appropriate droplet size distribution to reach the plasma. The spray chamber features a sand-blasted neck with EZ seal fitting…
-
The 50 mL borosilicate glass cyclonic Tracey spray chamber does not feature an internal baffle and is not hydroflouric acid-resistant. It relies on momentum to efficiently and quickly remove the larger droplets from the sample mist decreasing any opportunity for occlusion or agglomeration of the…