Sterile Inoculating Loops
-
Abdos Soft Inoculation Loop, Gamma Radiated, Sterile ABS
Foxx Life SciencesAbdos Soft Inoculation Loop is made of Acrylonitrile butadiene styrene (ABS) and has a smooth surface to provide uniform and gentle streaking without damaging the surface of gels/agar. A polygonal shaft improves grip and assists with orientation for ease of operation. Plates have been validated…
-
…colonies. Packed sterile in safe, tamper-proof, zip-seal resealable bags. Disposable inoculating loops and needles do not need flaming and thus eliminate the risk of infection due to aerosol formation of pathogenic substances. Cross-contamination due to improper sterilization is eliminated. They…
-
-
Inoculating Loops
Corning® Gosselin™Complete range of products from spreaders to inoculating loops Highly ergonomic Color coded for easy identification Sterile 10-3 Traceability on each bag
-
Sterile, disposable inoculating loops do not require flaming. Loops are made from a plastic resin that provides controlled flexibility. They resist cutting the agar surface yet provide sufficient firmness to pick stubborn colonies. Loops are color-coded for quick ID. State-of-the-art plastic…
-
…has a 10 μl loop at one end and a needle at the other. Neutral type has a 1 μl loop at one end and a needle at the other. In addition, one end of the inoculating loop has been designed to be used as an inoculating needle, giving these loops a double purpose. Sterile, disposable and…
-
For use with Thomas® Bacti Infrared Microsterilizer.
-
Inoculating Loops & Needles
Celltreat Scientific…color-coded for easy identification. The surface of the loops and needles are vacuum-gas plasma treated, they are packaged in peel-to-open paper/plastic wrappers and are sterile (gamma irradiated). An inoculation loop, also called a smear loop or micro-streaker, is a tool used by biologists to…
-
Inoculating Loops & Needles
Biologix…without damaging the gel surface Loops available in 1μL and 10μL sizes with strict measurement; the opposite end of each loop can be used as a needle Round-shaped needle avoid any damage during colonies selection Gamma radiation sterilized; non-pyrogenic Packed in zip-seal bag,…
-
Inoculating Loops and Needles
NEST Scientific USAPP material, hydrophilic Used in microbiology experiments Different colors for identification Flexible handles for easier collection and inoculation Sterilized by Ethylene Oxide Easy-tear Sterile individual packaging
-
Inoculating Loops and Needles
MTC BioThese sterile disposable plastic loops and needles are designed for use in quantitative procedures such as sampling, urine counts and serial dilutions, as well as for bacterial inoculation. Because they are pre-sterilized and designed for single use, t
-
Disposable Inoculating Loops and Needles
Thermo Scientific NuncEasily identify color-coded Thermo Scientific™ Nunc™ Disposable Loops and Needles, precision molded from nontoxic (USP Class VI) polystyrene material to provide a smooth loop surface. Thermo Scientific Nunc products are high quality plastics for use in biotechnology, pharmaceutical and…
-
Plastic Inoculating Loops
United Scientific SuppliesDisposable economical plastic loops for use when flame sterilization is not needed. Sterilized and packed in plastic sleeves of 30.
-
… Packed sterile in safe, tamperproof, zip-seal resealable bags. Disposable inoculating loops and needles do not require flaming and thus eliminate the risk of infection due to aerosol formation of pathogenic substances. Cross contamination due to improper sterilization is eliminated.…
-
Disposable Inoculating Loops & Needles
Argos Technologies…colonies. Packed sterile in safe, tamper proof, zip-seal resealable bags. Disposable inoculating loops and needles do not need flaming and thus eliminate the risk of infection due to aerosol formation of pathogenic substances. Cross-contamination due to improper sterilization is eliminated.…
-
Reusable Inoculating Loops & Needles
Argos Technologies…Argos Inoculating Loop Holders are made from nickel plated brass. Handles are insulated to protect the hand during use. Loop Holders are available in two sizes: 6" and 8". Inoculating Handles and Loops Reusable Inoculating Loops with handles are used to select, inoculate…
-
Secure Inoculating Loop White NS Polystyrene
Thermo Scientific Nunc1 µL secure white inoculation loop Polystyrene Non-sterile
-
Disposable Inoculating Needle/Loops
Heathrow Scientific…disposable needle/loops. Use loop end to uniformly streak gel surface; use needle for removal of colonies. Choose polypropylene (PP) needle/loops for more flexible handle use and acrylonitrile-butadiene-styrene (ABS) needle/loops for more rigid handle use. Come sterile for immediate use. 20…
-
InocuLoop™ Calibrated Disposable Loops
Evergreen ScientificInocuLoop™ disposable inoculating loops have patented*, four-sided spreaders—like four streakers in one! Inoculate a petri dish with one, not multiple, disposable loops. InocuLoop™ is also ideal for making all your bacterial inoculation and quantitative procedures—such as…
-
Disposable Inoculating Loops, Needles and Spreaders Accurate analysis of sample growth starts with proper specimen set up For specimen handling in Microbiology, loops, needles and spreaders are essential tools used in a variety of important tasks. Convenient sterile single-use loops. …
-
Astral Inoculation System
Bio PlasIndividual, sterile loops and needles Eliminate waste Disposable 1 µL and 10 µL loops Color coded Certified to be free of RNase, DNase, DNA, pyrogens and PCR inhibitors The Astral Inoculation System eliminates the metal or wire loop flaming step and the hazards…
-
Sterimax Electrical Sterilizer
WLD-TEC…its optimal temperature of 900°C (1650°F) after only a few minutes. To sterilize the inoculation loop, simply insert it into the ceramic annealing tube. After 5-7 seconds, the inoculation loop is sterilized*. A back side spray protector is integrated for more safety when handling with…
-
Microincinerators
Crystal Technologies…to sterilize metal inoculating loops and needles without using an open flame. By using infrared heat inside a ceramic tube, the product protects your laboratory technicians from dangerous gases, flames and splatters. Once it reaches optimum sterilization temperature(900?), the loop or needle…
-
SteriMax
WLD-TEC… The sterilizing tube, which is made of wear-resistant quartz glass, reaches its optimal temperature of 900° C (1650° F) after only a few minutes. To sterilize the inoculation loop, simply insert it into the quartz tube. After 5-7 seconds, the inoculation loop is sterilized. A spray…
-
Kit Ap Biology #8 Biotechnology: Bacterial Transformation
Innovating Science…1, 3, 5, 6, and 7, and Big Idea 3. Kit Includes: 30mL Sterile Calcium Chloride 0.05M 16 Sterile Volumetric Pipet 8 Pipet Bulb 8 Micropipet w/Plunger 10ul 1 Plastic Centrifuge Tube 16 Microcentrifuge Tube, 1.5mL 8 Sterile Inoculating Loop 40 Petri Dish 4 Luria Agar, 200mL 1 E. Coli Culture (freeze…
-
BactiZapper™ Infrared MicroSterilizer, 115V
Benchmark Scientific…instant sterilization of platinum inoculating loops, needles, glass tube/pipette mouths and various metal & borosilicate glass instruments used in the laboratory. An asbestos-free core element uses infrared heating to produce temperatures of 815°C (1500°F), to completely sterilize…
-
Infared MicroSterilizers
labForce® (powered by Thomas Scientific)…a research sterilizer that utilizes an asbestos-free core element that uses intense heating to produce 815°C (1500°F). It completely sterilizes in 5-7 seconds. The MicroSterilizer uses well-proven technology to provide instant sterilization of platinum inoculating loops, glass tube/pipette…
-
Kit Ap Bio#7 Cell Division:Mitosis And Meiosis
Innovating Science…Materials provided for 32 students in eight lab groups. Kit Includes: 10 Disposable scalpels, sterile 20 Petri Dishes, Sterile 200mL Sordaria Agar 200mL Sordaria Mating Agar 8 Disposable Inoculating Loops, Sterile 8 Forceps 1 pkg Microscope Slides 1 pkg Coverslips 16 Plastic Pipettes 8 Plastic Cups…
-
Glycerol
MP Biomedicals…to years in a liquid or solid form at -10 to -15°C or frozen at -20 to -80°C in 20-80% glycerol. Glycerol is added to fresh cells from liquid or plate cultures and stored in the freezer. Fresh media cultures are inoculated by dipping into the frozen stock with a sterile loop or pipette.
-
Bacti-Cinerator IV
Leica… Sterilizes loops and needles safely and conveniently Prevents infectious spatter and/or cross-contamination Safeguards laboratory personnel - no open flame or hazardous gas Sterilization takes only 5 to 7 seconds at optimum sterilizing temperature of 1,600°F; no need to wait for loops or…
-
Fuego SCS pro
WLD-TEC…or programs for short flame sterilization - exact to the second. When the burner is activated the display shows the remaining burning time. Moreover, the Fuego SCS pro automatically recognizes whether a foot pedal or the Autoloop Pro carrousel for inoculation loops is connected, and displays…
-
Brucella Agar Base
HiMedia…are incorporated into the base (6, 7, 8). Swab specimens can be directly streaked on the plate. Liquid specimens can be inoculated by means of an inoculation loop. When non-selective medium is required, Brucella Broth Base may be employed with the addition of serum only (i. e. without…